Proplant PCE

Electromagnetic flow meter

ALLMAG 4000 Electromagnetic Flow Meter

A full-bore magnetic flow meter for water, effluent, slurries and chemicals, in compact or remote versions, with a choice of liners and electrodes for the liquid you are measuring.

AllpronixElectromagneticDN10 to DN2000
ALLMAG 4000 compact electromagnetic flow meter with display
Product overview

What is the ALLMAG 4000?

The ALLMAG 4000 from Allpronix is an electromagnetic flow meter for electrically conductive liquids and slurries in full pipes.

  • 01Nothing in the flow pathA full-bore measuring tube with no moving parts and very little pressure loss.
  • 02Compact or remoteThe transmitter mounts on the sensor, or on a wall up to 10 m away with the standard cable.
  • 03Built for the liquidNeoprene, PU, PTFE, F46 or PFA liners and seven electrode materials.
Read more

The reading does not depend on the density, viscosity, temperature or pressure of the liquid, only on its velocity, so one meter suits water, effluent, slurry and chemicals once the liner and electrodes are right.

A low-frequency square-wave field, 16-bit processing and empty-pipe and electrode diagnostics keep the signal stable, and the outputs cover 4 to 20 mA, pulse, RS485 and HART.

Key features

Key Features of the ALLMAG 4000 Electromagnetic Flow Meter

01 / 06

Faraday principle

The induced voltage is proportional to flow velocity, so the reading is not affected by density, viscosity, temperature, pressure or conductivity above the minimum.

Turndown is up to 1500:1.

02 / 06

Liner choice

Neoprene for water, sewage and low-abrasion slurry, polyurethane for abrasive mineral slurry, and PTFE, F46 or PFA for strong acids and alkalis.

03 / 06

Electrode choice

316L stainless steel, Hastelloy B or C, titanium, tantalum, platinum-iridium or tungsten-carbide coated steel, matched to the corrosion and abrasion of the liquid.

04 / 06

Backlit display and keys

A high-definition backlit LCD shows flow rate, totals and alarms, with navigation keys for set-up.

05 / 06

Self-diagnostics

Intelligent empty-pipe detection and electrode resistance measurement flag an empty pipe or contaminated electrodes.

06 / 06

Outputs for the control system

4 to 20 mA, pulse or frequency, high and low alarm outputs, and RS485, RS232 or HART communication.

Technical specifications

ALLMAG 4000 Technical Specifications

Tap a group to filter the electromagnetic flow meter specifications, or show them all.

ALLMAG 4000 compact electromagnetic flow meter with display
ALLMAG 4000 compact electromagnetic flow meter.
ALLMAG 4000 electromagnetic flow meter in compact and remote versions
Compact version and remote version with wall-mount transmitter.
Electromagnetic flow measurement principle: magnetic field, flow velocity and induced voltage
The measuring principle: E = k · B · v · D.
  • 0.5%Accuracy1.0% version available
  • 15 m/sMaximum velocityturndown up to 1500:1
  • DN10 to DN2000Pipe sizesflanged as standard
  • IP68Protectionremote version
ALLMAG 4000 Technical Specifications
SpecificationDetails
Measured mediumElectrically conductive liquids and slurries, conductivity > 5 µS/cm (20 µS/cm for demineralised water)
Accuracy0.5% (1.0% version available); repeatability 0.2%
Flow velocityUp to 15 m/s; turndown up to 1500:1; response time 0.02 s
Pipe sizesDN10 to DN2000 (3/8" to 80"); flow ranges per size in the datasheet

Figures from the Allpronix ALLMAG 4000 datasheet. Confirm the size, liner, electrodes and options for your application before ordering.

Download Data Sheet
How it works

How does the ALLMAG 4000 work?

Step by step:

Flow is the velocity multiplied by the bore area, so the meter must run full. Install it after a pump and before a control valve, avoid the highest point of the line, and keep 10 × DN straight pipe upstream and 5 × DN downstream.

Interactive demonstration: coils create a magnetic field across the ALLMAG 4000 measuring tube, the conductive liquid induces a voltage at the electrodes in proportion to its velocity, and the transmitter converts it into flow and a 4 to 20 mA signalCOILCOILB FIELDELECTRODESFLOW →E = k · B · v · DVELOCITY2.0 m/sPIPEDN100SIGNAL∝ v · DFLOW56.5 m³/hOUTPUT7.2 mA0 · 4 mA10 m/s · 20 mASTEP 01ILLUSTRATIVE, 0 TO 10 m/s = 4 TO 20 mA
PIPE
ALLMAG 4000 electromagnetic flow meter: move the velocity, pick a pipe size or click a step to see how the induced voltage becomes a flow reading.
Applications

Where the ALLMAG 4000 is used

Typical applications for this electromagnetic flow meter, from the manufacturer's documentation.

  • 01Water and wastewaterRaw water, potable water, sewage and effluent lines, with neoprene liners and 316L electrodes.
  • 02Mining and mineralsMineral and coal slurries, with polyurethane liners for abrasive duty.
  • 03Chemical processingAcids, alkalis and corrosive media with PTFE, F46 or PFA liners and Hastelloy, titanium or tantalum electrodes.
  • 04Food, beverage, pulp and paperProcess water, product lines and paper stock in full pipes.
Compare the range

How the ALLMAG 4000 compares

The highlighted row is this instrument. Tap any other name to open its page.

How the ALLMAG 4000 compares
InstrumentPrincipleRangeOutputSupplyProtection
Electromagnetic
ALLMAG 4000 electromagnetic flow meterElectromagneticDN10 to DN2000, up to 15 m/s4 to 20 mA, pulse, RS485, HART100 to 240 V AC or 24 V DCIP65 compact, IP68 remote
ALLMAG 5000 IO-Link electromagnetic flow meterElectromagnetic0.01 l/min (G¼) to DN100 flangedIO-Link, 4 to 20 mA, pulse, switch19 to 30 V DCIP67
Coriolis
Coriolis mass flow meterCoriolisDN3 to DN150, up to 360 t/h2 × 4 to 20 mA, pulse, Modbus, HART24 V DC or 220 V ACIP67
Flow sensor
ALL-005 programmable thermal flow sensorThermal (calorimetric)0.04 to 3 m/s liquids, 2 to 100 m/s air2 × switch, 4 to 20 mA, IO-Link18 to 30 V DCIP65 / IP67
Differential pressure
Itabar and deltaflow pitot flow tubesDifferential pressureDN40 up to DN12000Via the DP transmitterPassive sensorStainless steel, up to 400 °C (IBF)
Proplant PCE

From Selection to a Working Signal in Your Control System

A flow meter is only as useful as the signal that reaches the control room. Proplant PCE handles the steps around the instrument as well as the instrument itself.

01 / 04

Application review

We check the liquid or gas, pipe size, flow range, process conditions and output before recommending a meter.

02 / 04

Supply

Instruments from the brands on this page, with datasheets and calibration certificates for your engineering file.

03 / 04

Installation

Mechanical installation, earthing, cabling and termination by our E&I team.

04 / 04

Integration

Signal wiring and configuration into your PLC or SCADA, including Siemens systems.

Before you order

What to tell us so we can recommend an instrument

Tick off what you already know. We will check the ALLMAG 4000 against your conditions, or suggest a better fit from our range.

FAQ

ALLMAG 4000 FAQ

What can the ALLMAG 4000 measure?

Electrically conductive liquids and slurries in full pipes, with a conductivity above 5 µS/cm (20 µS/cm for demineralised water). It cannot measure oils, gases or other non-conductive media.

How accurate is it?

The standard version is 0.5% with 0.2% repeatability. A 1.0% version is also available.

Which liner should I choose?

Neoprene suits water, sewage and low-abrasion slurry, polyurethane suits abrasive mineral and coal slurry, and PTFE, F46 or PFA suit strong acids and alkalis and higher temperatures.

What straight pipe does it need?

At least 10 × DN upstream and 5 × DN downstream to meet the accuracy specification.

Can the transmitter be mounted away from the pipe?

Yes. The remote version has a wall-mount transmitter connected by a 10 m cable as standard, and the sensor is rated IP68.

Does it connect to a PLC or SCADA?

Yes. Outputs include 4 to 20 mA, pulse and alarm outputs, with RS485, RS232 or HART communication.

Can Proplant PCE help me size the meter?

Yes. Send us the liquid, pipe size, flow range and process conditions and we will recommend a size, liner and electrode material.

ALLMAG 4000 electromagnetic flow meter

Let's Discuss Your Flow Application

Tell us what is flowing, the pipe it flows in and what the signal needs to do. We will come back with a recommendation and the datasheet.

Scroll to Top