What is the ALLMAG 5000?

The ALLMAG 5000 from Allpronix is an electromagnetic flow meter with IO-Link, built for small and medium flows of conductive liquids.

  • 01IO-Link and 4 to 20 mAOutput 1 can run as IO-Link, and both outputs can be analogue, switch, pulse or frequency.
  • 02Colour TFT displayA multi-parameter display, rotatable in 90° steps, set up with four optical touch keys.
  • 03Batching built inA dosing function with an external control input, plus a grand and a resettable totaliser.
Read more

Two models make up the range. The MIM is an all-metal 316L meter with threaded connections from G¼ to G2, for flows from 0.01 l/min up to 650 l/min, and it measures temperature as well as flow.

The MIS is a flanged meter in DN80 and DN100 (3" and 4") for medium-sized water lines, with an NBR liner and Hastelloy C276 electrodes. Both measure in both directions.

Key features

Key Features of the ALLMAG 5000 IO-Link Electromagnetic Flow Meter

01 / 06

IO-Link communication

IO-Link V1.1 on output 1, COM3 bit rate and 1.1 ms minimum cycle time (MIS), with SIO mode and block parameterisation.

02 / 06

Two configurable outputs

Each output can be 4 to 20 mA, 0 to 20 mA, 0 to 10 V or 2 to 10 V, an NPN, PNP or push-pull switch, or a pulse or frequency output.

03 / 06

Dosing and batching

Output 2 runs a dosing output while output 1 acts as the start, stop and reset input.

A grand totaliser and a resettable totaliser are both kept.

04 / 06

Bidirectional measuring

Flow is measured in both directions.

05 / 06

Colour display, touch keys

A 1.4" 128 × 128 TFT display rotates in 90° steps, changes colour on limit violations, and the four optical touch fields work with gloves.

06 / 06

Temperature as well (MIM)

The MIM has a Pt1000 temperature sensor, so one device reports flow and liquid temperature.

Technical specifications

ALLMAG 5000 Technical Specifications

Tap a group to filter the IO-Link flow meter specifications, or show them all.

ALLMAG 5000 MIS flanged electromagnetic flow meter with IO-Link
ALLMAG 5000 MIS flanged meter, DN80 and DN100.
ALLMAG 5000 MIM compact stainless steel electromagnetic flow meter with TFT display
ALLMAG 5000 MIM all-metal compact meter.
ALLMAG 5000 MIM electromagnetic flow meter, front view of the display
MIM colour TFT display with flow and temperature.
  • IO-LinkCommunicationplus 4 to 20 mA
  • 0.01 to 650 l/minMIM rangeG¼ to G2
  • DN80 / DN100MIS flanged3" and 4"
  • IP67Protection
ALLMAG 5000 Technical Specifications
SpecificationDetails
Measured mediumConductive liquids, minimum conductivity ≥ 20 µS/cm, maximum viscosity 70 mm²/s
MIM rangesG¼: 0.01 to 1 l/min; G½: 0.03 to 3 or 0.04 to 10 l/min; G¾: 0.1 to 25 or 0.2 to 50 l/min; G1: 0.2 to 50 or 0.4 to 100 l/min; G2: 1.5 to 350 or 3 to 650 l/min
MIS sizesDN80 (3") and DN100 (4") flanged
AccuracyMIM: < ±(0.8% of reading + 0.5% of full scale); MIS: < ±(0.5% of reading + 0.3% of full scale); repeatability ±0.2% of full scale
Response timeFlow t90 < 250 ms (alarm and pulse output); MIM temperature t90 < 20 s

Figures from the Allpronix ALLMAG 5000 MIM and MIS datasheets. Confirm the model, size and options for your application before ordering.

Download Data Sheet
How it works

How does the ALLMAG 5000 work?

Step by step:

The measurement does not depend on density, viscosity or temperature. Output 1 can be set to IO-Link so the PLC reads flow, totals and status digitally, while output 2 stays free for an alarm or a batching signal.

Interactive demonstration: coils create a magnetic field across the ALLMAG 5000 measuring tube, the conductive liquid induces a voltage at the electrodes in proportion to its velocity, and the meter sends flow over IO-Link or 4 to 20 mACOILCOILB FIELDELECTRODESFLOW →E = k · B · v · DVELOCITY2.0 m/sPIPEDN100SIGNAL∝ v · DFLOW56.5 m³/hOUTPUT7.2 mA0 · 4 mA3 m/s · 20 mASTEP 01ILLUSTRATIVE, 0 TO 3 m/s = 4 TO 20 mA
SIZE
ALLMAG 5000 IO-Link flow meter: move the velocity, pick a connection size or click a step to see how the induced voltage becomes a flow reading.
Applications

Where the ALLMAG 5000 is used

Typical applications for this IO-Link flow meter, from the manufacturer's documentation.

  • 01Batching and dosingFilling and dosing with the built-in batching function and external start input.
  • 02Water treatment and tappingWater treatment, water tapping, watering and waste water treatment.
  • 03Leak detectionWater distribution networks, for leakage detection and management.
  • 04Filtration and machinesReverse osmosis and ultrafiltration systems, cooling water and industrial machines.
Compare the range

How the ALLMAG 5000 compares

The highlighted row is this instrument. Tap any other name to open its page.

How the ALLMAG 5000 compares
InstrumentPrincipleRangeOutputSupplyProtection
Electromagnetic
ALLMAG 4000 electromagnetic flow meterElectromagneticDN10 to DN2000, up to 15 m/s4 to 20 mA, pulse, RS485, HART100 to 240 V AC or 24 V DCIP65 compact, IP68 remote
ALLMAG 5000 IO-Link electromagnetic flow meterElectromagnetic0.01 l/min (G¼) to DN100 flangedIO-Link, 4 to 20 mA, pulse, switch19 to 30 V DCIP67
Coriolis
Coriolis mass flow meterCoriolisDN3 to DN150, up to 360 t/h2 × 4 to 20 mA, pulse, Modbus, HART24 V DC or 220 V ACIP67
Flow sensor
ALL-005 programmable thermal flow sensorThermal (calorimetric)0.04 to 3 m/s liquids, 2 to 100 m/s air2 × switch, 4 to 20 mA, IO-Link18 to 30 V DCIP65 / IP67
Differential pressure
Itabar and deltaflow pitot flow tubesDifferential pressureDN40 up to DN12000Via the DP transmitterPassive sensorStainless steel, up to 400 °C (IBF)
Proplant PCE

From Selection to a Working Signal in Your Control System

A flow meter is only as useful as the signal that reaches the control room. Proplant PCE handles the steps around the instrument as well as the instrument itself.

01 / 04

Application review

We check the liquid or gas, pipe size, flow range, process conditions and output before recommending a meter.

02 / 04

Supply

Instruments from the brands on this page, with datasheets and calibration certificates for your engineering file.

03 / 04

Installation

Mechanical installation, earthing, cabling and termination by our E&I team.

04 / 04

Integration

Signal wiring and configuration into your PLC or SCADA, including Siemens systems.

Before you order

What to tell us so we can recommend an instrument

Tick off what you already know. We will check the ALLMAG 5000 against your conditions, or suggest a better fit from our range.

FAQ

ALLMAG 5000 FAQ

What is the difference between the MIM and the MIS?

The MIM is a compact all-metal meter with threaded connections from G¼ to G2 and a temperature sensor. The MIS is a flanged meter in DN80 and DN100 for medium-sized water lines.

What does IO-Link add?

Output 1 can run as an IO-Link port, so the PLC reads flow, totals and settings digitally over a standard 3-wire sensor cable, and the meter can be parameterised remotely.

Can it still give a 4 to 20 mA signal?

Yes. Both outputs can be set to 4 to 20 mA, 0 to 20 mA, 0 to 10 V or 2 to 10 V, or to switch, pulse or frequency outputs.

Can it batch or dose?

Yes. A dosing function uses output 2 as the dosing output and output 1 as the start, stop and reset input.

What liquids can it measure?

Conductive liquids of at least 20 µS/cm and up to 70 mm²/s viscosity, such as water and many water-based process liquids.

Can Proplant PCE help me choose the right model?

Yes. Send us the liquid, pipe size, flow range and the signal your PLC needs, and we will recommend the model and range.

ALLMAG 5000 IO-Link electromagnetic flow meter