Balluff BCM Condition Monitoring Sensors for Vibration and Temperature
Compact IO-Link sensors that measure 3-axis vibration and contact temperature on motors, pumps and fans, so faults show before they stop the plant.

Key Features of the Balluff BCM sensor
Vibration and temperature
BCM0001: 3-axis vibration, -16 to 16 g, 2 to 2500 Hz (±3 dB), and contact temperature from -25 to +70 °C.
Ambient conditions too
BCM0002 adds relative humidity (5 to 95 %RH) and ambient pressure (300 to 1100 hPa).
Wider range
BCM0004: 2 to 6000 Hz (±3 dB) and contact temperature from -40 to +80 °C.
Device data
BCM0004 adds operating hours, boot cycle and switching counters, voltage and current monitoring, and internal temperature.
Robust housing
1.4404 stainless steel; IP67, IP68 and IP69K on BCM0001 and BCM0004.
IO-Link
IO-Link 1.1 (BCM0001, BCM0002) and 1.1.3 (BCM0004).
Balluff BCM sensor Technical Specifications
Tap a group to filter the condition monitoring sensor specifications, or show them all.

- 3Axesvibration
- ±16gmeasuring range
- 6000HzBCM0004, ±3 dB
- IP69KProtectionBCM0001, BCM0004
| Specification | Details |
|---|---|
| Functions | BCM0001, BCM0004: vibration analysis in time domain, contact temperature. BCM0002: also relative humidity and ambient pressure |
| Vibration, measuring range | -16 to 16 g, 3 axes |
| Vibration, frequency range | BCM0001, BCM0002: 2 to 1800 Hz (±10 %), 2 to 2500 Hz (±3 dB). BCM0004: 2 to 4500 Hz (±10 %), 2 to 6000 Hz (±3 dB) |
| Contact temperature | BCM0001, BCM0002: -25 to +70 °C. BCM0004: -40 to +80 °C |
| Humidity and pressure (BCM0002) | 5 to 95 %RH; 300 to 1100 hPa |
| Interface | IO-Link 1.1 (BCM0001, BCM0002); IO-Link 1.1.3 (BCM0004) |
| Device data (BCM0004) | Identification, device discovery, switching counter, operating hours counter, boot cycle counter, voltage and current monitoring, pin assignment, internal temperature |
| Connection | Cable with connector, 1.5 m PUR, M12x1 male: 3-pin (BCM0001, BCM0002), 4-pin (BCM0004) |
| Housing | 1.4404 stainless steel; BCM0002 membrane ePTFE with nylon fleece |
| Rated operating voltage | 24 V DC |
| Protection | BCM0001, BCM0004: IP67, IP68, IP69K. BCM0002: IP67 |
| Ambient temperature | BCM0001, BCM0002: -25 to 70 °C. BCM0004: -40 to 80 °C |
Figures from the Balluff product page for each model, read in November 2026. Confirm the frequency range and mounting for your machine before ordering.
- Balluff Condition Monitoring brochure (PDF)
- Balluff BCM0001 data sheet (PDF)
- Balluff BCM0002 data sheet (PDF)
- Balluff BCM0004 data sheet (PDF)
How does the Balluff BCM sensor work?
Tap a step, or let it run, to follow the signal from the field to the control system.
Step by step:
The BCM is fixed to the machine and measures vibration on three axes and the temperature of the surface it sits on. It sends these values over IO-Link, so the control system can watch them over time and warn when a bearing, mounting or load starts to change, before it becomes a breakdown.
Where the Balluff BCM sensor is used
Typical applications for this condition monitoring sensor, from the manufacturer's documentation.
- 01Machine vibrationMonitoring motors, pumps and fans for vibration on three axes.
- 02TemperatureWatching the contact temperature of the machine surface.
- 03Predictive maintenanceTrend data over IO-Link to plan maintenance.
How the Balluff BCM sensor compares
Other io-link and balluff in our range. The highlighted row is this product. Tap any other name to open its page.
| Product | Type | Signals | Outputs and communication | Supply | Mounting |
|---|---|---|---|---|---|
| Balluff Multiprotocol IO-Link Masters | IO-Link master | 8 IO-Link ports | PROFINET, EtherNet/IP, EtherCAT, Modbus TCP | 18 to 30 VDC | Machine, IP67 to IP69K |
| Balluff IO-Link Sensor and Actuator Hubs | IO-Link hub | 16 DI and 16 DO, or 8 analogue in | IO-Link to one master port | 18 to 30.2 VDC | Machine, IP67 |
| Balluff IO-Link Sensors | IO-Link sensors | Inductive, optical, capacitive, magnetic, distance, pressure | IO-Link 1.1 plus switching or analogue | 10 to 30 VDC, model dependent | Machine and process |
| Balluff Condition Monitoring Sensors | Condition monitoring sensor | 3-axis vibration, contact temperature | IO-Link | 24 V DC | Machine mount, IP67 to IP69K |
| autosen AS005 IO-Link Flow Sensor | Thermal flow sensor | Flow and temperature, liquids and gases | 2 switching, 4 to 20 mA, IO-Link | 18 to 30 V DC | M18 x 1.5 adapter, IP65 and IP67 |
| Balluff IO-Link Safety Hub | Safety I/O hub | 12 safe inputs, 2 safe outputs | PROFIsafe over IO-Link | 19.2 to 30 V | Machine, IP67 |
| Balluff Heartbeat Power Supplies with IO-Link | 24 V power supply | 192 to 360 W | IO-Link diagnostics | 85 to 264 V AC in, model dependent | DIN rail IP20 or field IP67 |
| Balluff M12 Cordsets and Splitters | M12 cordsets | Single, double-ended, Y-splitter, NAMUR | Sensor and power cable | 250 VDC / 250 VAC, 4 A | IP67 to IP69K |
From Selection to a Working Signal in Your Control System
A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.
Application review
We check the signals, channel count, network and mounting before recommending a device.
Supply
Instruments and modules from the brands on this page, with the brochure for your engineering file.
Configuration and installation
Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.
Integration
Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.
What to tell us so we can recommend a device
Tick off what you already know. We will check the Balluff BCM sensor against your application, or suggest a better fit from our range.
Balluff BCM sensor FAQ
What does a condition monitoring sensor measure?
The BCM measures vibration on three axes and contact temperature. BCM0002 also measures relative humidity and ambient pressure.
Which model has the widest vibration range?
BCM0004, from 2 to 6000 Hz (±3 dB).
How does the data reach the control system?
Over IO-Link, through an IO-Link master such as the Balluff multiprotocol IO-Link master.
Is it suitable for washdown areas?
BCM0001 and BCM0004 are rated IP67, IP68 and IP69K, with a stainless steel housing.
Can Proplant PCE help me choose the right automation device?
Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.
Let's Discuss Your Automation Project
Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.