Automation products that get field signals into your control system
Data loggers and IIoT, digital indicators and controllers, Ethernet I/O, signal isolators and converters, and IO-Link. Selected for the signals, the network and the system they report to, then configured and integrated by Proplant PCE.
The link between the field and the control room
Automation depends on the signal path as much as on the PLC. A reading that arrives scaled wrongly, picks up noise through a ground loop, or never reaches the network leaves operators guessing and control loops running on bad data.
Indicators put values where operators can see them, isolators and converters keep signals clean, Ethernet I/O and IO-Link carry them over the network, and data loggers keep a record. We match each device to your signals and to the system that reads them.
Four groups, one signal path
Pick a group to see what it does and which products we supply in it.
Data loggers and a cloud platform that record plant signals and make them available remotely.
Panel and field displays, PID control and alarm relays for process values.
- ACS DPA Digital Display UnitDisplay, relays and isolation→
- NOVUS N1050 PID Temperature ControllerPID controller, 48 x 48→
- NOVUS N1040i Process IndicatorProcess indicator, 48 x 48→
- NOVUS N1540 Universal IndicatorUniversal indicator, 96 x 48→
- NOVUS LoopView Loop-Powered IndicatorLoop-powered field indicator→
Ethernet I/O, isolators and universal converters that get field signals into the PLC cleanly.
- Acromag BusWorks XT1540 Ethernet I/O ModuleEthernet I/O, analogue out and discrete→
- Acromag 961EN and 962EN Analogue Input Ethernet I/OEthernet I/O, 6 analogue inputs→
- Acromag 981EN, 982EN and 983EN Discrete Ethernet I/OEthernet I/O, 12 discrete channels→
- Datexel DAT 511 Loop-Powered Current IsolatorLoop-powered isolator→
- Datexel DAT 4135 Isolated Universal Signal ConverterUniversal converter, 24 Vdc→
- Datexel DAT 4035 Loop-Powered Universal TransmitterUniversal, loop powered→
Balluff IO-Link masters, hubs, sensors, safety, condition monitoring, power supplies and cordsets, and autosen flow sensors.
- Balluff Multiprotocol IO-Link MastersIO-Link master, 8 ports→
- Balluff IO-Link Sensor and Actuator HubsIO-Link hubs, digital and analogue→
- Balluff IO-Link SensorsIO-Link sensors, six families→
- Balluff Condition Monitoring SensorsVibration and temperature sensor, IO-Link→
- autosen AS005 IO-Link Flow SensorThermal flow sensor, IO-Link→
- Balluff IO-Link Safety HubSafety I/O over IO-Link→
- Balluff Heartbeat Power Supplies with IO-Link24 V power supplies, IO-Link→
- Balluff M12 Cordsets and SplittersM12 cordsets and splitters→
22 automation products
Filter by group, open a product for its full specification sheet, or download the manufacturer's brochure.
NOVUS · IIoT cloud platformNOVUS Cloud IIoT Platform
An IoT platform that receives, stores, analyses and presents measurements from NOVUS devices, with dashboards you can customise and alarms by email or SMS.
- Email / SMSAlarms
- DashboardsPresentation
- ScriptsData processing
NOVUS · Data logger, 8 universal inputsNOVUS FieldLogger Data Logger
A high-resolution, high-speed data logger with 8 universal analogue inputs, 8 configurable digital I/O, 2 relays, alarms and maths channels, connected over Modbus and Ethernet.
- 8Universal inputs
- 1000 / sLogging rate
- 24 bitResolution
NOVUS · Wireless data loggerNOVUS LogBox Connect Wireless Data Logger
A family of multichannel data loggers that record analogue and digital signals and send them on by Bluetooth, Wi-Fi or cellular, running on AA batteries or an external supply.
- 140,000Records
- 15 bitResolution
- 2 yearsBattery life
ACS-Control-System · Display, relays and isolationACS DPA Digital Display Unit
A digital display unit that shows, processes and galvanically separates standard 0 to 10 V and 0/4 to 20 mA signals, with an isolated analogue output, up to 4 relays and an optional data logger.
- ≤ 0.2 %Accuracy
- 4Relays
- 500,000Logged readings
NOVUS · PID controller, 48 x 48NOVUS N1050 PID Temperature Controller
A PID temperature controller with a multicolour LCD display in a 48 x 48 mm case, with SSR and relay outputs, USB configuration and optional RS485 Modbus RTU.
- 48 x 48Panel size
- IP65Protection
- 6 VAConsumption
NOVUS · Process indicator, 48 x 48NOVUS N1040i Process Indicator
A universal process indicator in a 48 x 48 mm case that reads thermocouple, Pt100 and linear signals, with up to two alarm relays and an optional retransmission output or 24 Vdc supply.
- 0.2 %Accuracy
- 2Alarm relays
- 48 x 48Panel size
NOVUS · Universal indicator, 96 x 48NOVUS N1540 Universal Indicator
A 96 x 48 mm universal indicator with a bright 14 mm display, thermocouple, Pt100 and linear inputs, two alarm relays, USB configuration and optional RS485 Modbus RTU.
- 96 x 48Panel size
- 14 mmDisplay height
- 2Alarm relays
NOVUS · Loop-powered field indicatorNOVUS LoopView Loop-Powered Indicator
A 4 to 20 mA indicator powered by the loop itself.
- 0.1 %Accuracy
- < 3 VVoltage drop
- -40 to 85 °COperating temperature
Acromag · Ethernet I/O, analogue out and discreteAcromag BusWorks XT1540 Ethernet I/O Module
A slim DIN rail Ethernet I/O module with 8 analogue voltage outputs and 4 discrete I/O channels, in Modbus TCP, EtherNet/IP and PROFINET versions.
- 8 + 4Channels
- ±0.1 %Accuracy
- 1500 V ACIsolation
Acromag · Ethernet I/O, 6 analogue inputsAcromag 961EN and 962EN Analogue Input Ethernet I/O
Stand-alone Ethernet I/O modules with 6 differential inputs, current on the 961EN and voltage on the 962EN, communicating by Modbus TCP/IP or EtherNet/IP and set up from a web browser.
- 6Inputs
- ±0.05 %Accuracy
- 1500 V ACIsolation
Acromag · Ethernet I/O, 12 discrete channelsAcromag 981EN, 982EN and 983EN Discrete Ethernet I/O
12-channel discrete Ethernet I/O modules: inputs on the 981EN, outputs on the 982EN and both on the 983EN, communicating by Modbus TCP/IP or EtherNet/IP with no software needed.
- 12Channels
- 500 mAOutput current
- 1500 V ACIsolation
Datexel · Loop-powered isolatorDatexel DAT 511 Loop-Powered Current Isolator
A passive current loop isolator that takes its power from the measurement loop and reproduces the input current as an isolated output of the same value, with 3000 Vac isolation.
- 3000 VacIsolation
- ±0.25 %Transmission error
- 700 ΩMax. output load
Datexel · Universal converter, 24 VdcDatexel DAT 4135 Isolated Universal Signal Converter
An isolated universal signal converter that measures and linearises RTD, thermocouple, resistance, current, voltage and potentiometer signals and turns them into a current or voltage output.
- 2000 VacIsolation
- ±0.1 %RTD linearity
- 18 to 30 VdcSupply
Datexel · Universal, loop poweredDatexel DAT 4035 Loop-Powered Universal Transmitter
A two-wire isolated universal transmitter that turns RTD, thermocouple, resistance, potentiometer, mV, V and mA signals into a 4 to 20 mA loop signal, programmed from a PC.
- 2000 VacIsolation
- ±0.1 %RTD linearity
- 10 to 32 VdcLoop supply
Balluff · IO-Link master, 8 portsBalluff Multiprotocol IO-Link Masters
Field-mounted IO-Link masters with 8 ports that run PROFINET, EtherNet/IP, EtherCAT or Modbus TCP from one device, with REST API and MQTT for IIoT data.
- 8IO-Link ports
- 4Fieldbuses
- 18 to 30VDC
Balluff · IO-Link hubs, digital and analogueBalluff IO-Link Sensor and Actuator Hubs
Field-mounted hubs that collect up to 16 digital inputs and outputs, or 8 analogue signals, and bring them to one port of an IO-Link master.
- 16 / 16Digital I/O
- 8Analogue inputs
- 18 to 30.2VDC
Balluff · IO-Link sensors, six familiesBalluff IO-Link Sensors
Sensors that send their switching state, measured value and diagnostics over IO-Link, so they can be set up and monitored from the PLC.
- 6Sensor families
- IO-Link 1.1Interface
- 0 to 400bar
Balluff · Vibration and temperature sensor, IO-LinkBalluff Condition Monitoring Sensors
Compact IO-Link sensors that measure 3-axis vibration and contact temperature on motors, pumps and fans, so faults show before they stop the plant.
- 3Axes
- ±16g
- 6000Hz
autosen · Thermal flow sensor, IO-Linkautosen AS005 IO-Link Flow Sensor
A thermal flow sensor that measures flow and temperature at the same time, with two outputs, a colour display and IO-Link for water, glycol, oils and air.
- 0.04 to 3m/s
- 2 to 100m/s
- -20 to 90°C
Balluff · Safety I/O over IO-LinkBalluff IO-Link Safety Hub
A safety I/O module that connects to an IO-Link master and carries safety signals to the safety PLC as PROFIsafe over IO-Link, alongside standard I/O.
- 12 / 2Safe inputs / outputs
- PL eSafety level
- 20 msResponse time
Balluff · 24 V power supplies, IO-LinkBalluff Heartbeat Power Supplies with IO-Link
An IO-Link power supply that delivers 24 V DC to sensors, actuators and controllers and reports its own status and diagnostics, in the cabinet or the field.
- 24V DC
- 192 to 360W
- IP67Protection
Balluff · M12 cordsets and splittersBalluff M12 Cordsets and Splitters
M12 cables that connect sensors and actuators to IO-Link masters, hubs and I/O, from standard PUR cordsets to washdown splitters.
- 250V DC / V AC
- 4.0A
- IP69KProtection
Compare the range
Swipe the table sideways on a phone. Tap a name to open its page.
| Product | Type | Signals | Outputs and communication | Supply | Mounting |
|---|---|---|---|---|---|
| Data acquisition and IIoT | |||||
| NOVUS Cloud IIoT Platform | IIoT cloud platform | Data from NOVUS devices | Dashboards, email and SMS alarms | Hosted platform | Online |
| NOVUS FieldLogger Data Logger | Data logger | 8 universal analogue, 8 digital I/O | RS485 Modbus RTU, Ethernet, Modbus TCP, USB | 100 to 240 Vac | Panel |
| NOVUS LogBox Connect Wireless Data Logger | Wireless data logger | Universal analogue, 1 digital | Bluetooth, Wi-Fi with Modbus TCP and MQTT, USB | 4 AA batteries or 10 to 30 Vdc | Wall or field, IP40 |
| Digital indicators and controllers | |||||
| ACS DPA Digital Display Unit | Digital display unit | 0/4 to 20 mA, 0 to 10 V | Isolated analogue out, up to 4 relays, Bluetooth or USB | 18 to 36 V DC or 186 to 253 VAC | Panel, field or DIN rail |
| NOVUS N1050 PID Temperature Controller | PID controller | Thermocouple J, K, T, S; Pt100 | SSR pulse, relays, USB, optional Modbus RTU | 100 to 240 Vac/dc | Panel, 48 x 48 mm |
| NOVUS N1040i Process Indicator | Process indicator | Thermocouple, Pt100, mA, mV, V | 2 relays, optional retransmission and RS485 | 100 to 240 Vac or 48 to 240 Vdc | Panel, 48 x 48 mm |
| NOVUS N1540 Universal Indicator | Universal indicator | Thermocouple, Pt100, mA, mV, V | 2 relays, USB, optional Modbus RTU | 100 to 240 Vac/dc | Panel, 96 x 48 mm |
| NOVUS LoopView Loop-Powered Indicator | Loop-powered indicator | 4 to 20 mA loop | Local LED display | Loop powered | On the sensor connector |
| Signal converters and isolators | |||||
| Acromag BusWorks XT1540 Ethernet I/O Module | Ethernet I/O | 4 discrete I/O | 8 analogue out; Modbus TCP, EtherNet/IP or PROFINET | 12 to 32 V DC | DIN rail, 22.5 mm |
| Acromag 961EN and 962EN Analogue Input Ethernet I/O | Ethernet I/O | 6 differential current or voltage inputs | Modbus TCP or EtherNet/IP | 15 to 36 V DC | DIN rail |
| Acromag 981EN, 982EN and 983EN Discrete Ethernet I/O | Ethernet I/O | 12 discrete inputs, outputs or both | Modbus TCP or EtherNet/IP | 15 to 36 V DC | DIN rail |
| Datexel DAT 511 Loop-Powered Current Isolator | Loop isolator | 0 to 20 mA | Isolated 0 to 20 mA | Loop powered | DIN rail, 17 mm |
| Datexel DAT 4135 Isolated Universal Signal Converter | Universal converter | RTD, TC, mV, V, mA, resistance | Isolated current or voltage | 18 to 30 Vdc | DIN rail |
| Datexel DAT 4035 Loop-Powered Universal Transmitter | Universal transmitter | RTD, TC, mV, V, mA, resistance | Isolated 4 to 20 mA loop | Loop powered, 10 to 32 Vdc | DIN rail |
| IO-Link and Balluff | |||||
| Balluff Multiprotocol IO-Link Masters | IO-Link master | 8 IO-Link ports | PROFINET, EtherNet/IP, EtherCAT, Modbus TCP | 18 to 30 VDC | Machine, IP67 to IP69K |
| Balluff IO-Link Sensor and Actuator Hubs | IO-Link hub | 16 DI and 16 DO, or 8 analogue in | IO-Link to one master port | 18 to 30.2 VDC | Machine, IP67 |
| Balluff IO-Link Sensors | IO-Link sensors | Inductive, optical, capacitive, magnetic, distance, pressure | IO-Link 1.1 plus switching or analogue | 10 to 30 VDC, model dependent | Machine and process |
| Balluff Condition Monitoring Sensors | Condition monitoring sensor | 3-axis vibration, contact temperature | IO-Link | 24 V DC | Machine mount, IP67 to IP69K |
| autosen AS005 IO-Link Flow Sensor | Thermal flow sensor | Flow and temperature, liquids and gases | 2 switching, 4 to 20 mA, IO-Link | 18 to 30 V DC | M18 x 1.5 adapter, IP65 and IP67 |
| Balluff IO-Link Safety Hub | Safety I/O hub | 12 safe inputs, 2 safe outputs | PROFIsafe over IO-Link | 19.2 to 30 V | Machine, IP67 |
| Balluff Heartbeat Power Supplies with IO-Link | 24 V power supply | 192 to 360 W | IO-Link diagnostics | 85 to 264 V AC in, model dependent | DIN rail IP20 or field IP67 |
| Balluff M12 Cordsets and Splitters | M12 cordsets | Single, double-ended, Y-splitter, NAMUR | Sensor and power cable | 250 VDC / 250 VAC, 4 A | IP67 to IP69K |
What to tell us so we can recommend a device
Send us the signals, channel count, network and mounting, and our team will recommend a suitable device.
From Selection to a Working Signal in Your Control System
A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.
Application review
We check the signals, channel count, network and mounting before recommending a device.
Supply
Instruments and modules from the brands on this page, with the brochure for your engineering file.
Configuration and installation
Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.
Integration
Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.
Frequently asked questions
What does Proplant PCE supply for automation?
Data loggers and an IIoT platform, digital indicators and PID controllers, Ethernet I/O, signal isolators and converters, and IO-Link devices, together with the panel work, configuration and integration around them.
How do I get field signals onto an Ethernet network?
An Ethernet I/O module such as the Acromag 961EN or 983EN reads analogue or discrete signals in a remote panel and publishes them over Modbus TCP or EtherNet/IP.
When do I need a signal isolator?
When a ground loop, a shared signal or a noisy earth upsets a reading. The Datexel DAT 511 isolates a current loop without a separate supply.
Can a sensor be converted to 4 to 20 mA on the DIN rail?
Yes. The Datexel DAT 4035 converts RTD, thermocouple, resistance and other signals to an isolated 4 to 20 mA loop, and the DAT 4135 to current or voltage.
Which indicator suits a field transmitter with no spare power?
The NOVUS LoopView is powered by the 4 to 20 mA loop and fits between the sensor and its connector.
Can I log data at a site with no power?
Yes. The NOVUS LogBox Connect runs on AA batteries and is read by Bluetooth, Wi-Fi or USB.
What do I need to start with IO-Link?
An IO-Link master for your fieldbus, such as the Balluff multiprotocol IO-Link master, and IO-Link devices such as Balluff IO-Link sensors or the autosen AS005 flow sensor. Safety devices can join the same system through the Balluff Safety Hub.
Can Proplant PCE help me choose the right automation device?
Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.
Do these devices connect to my PLC or SCADA?
Yes. Depending on the model they offer Modbus RTU, Modbus TCP, EtherNet/IP, PROFINET, MQTT, relays or analogue signals. Tell us what your system uses and we will match it.
Let's Discuss Your Automation Project
Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.