Proplant PCE

Process indicator

NOVUS N1040i Universal Process Indicator with Alarm Relays

A universal process indicator in a 48 x 48 mm case that reads thermocouple, Pt100 and linear signals, with up to two alarm relays and an optional retransmission output or 24 Vdc supply.

NOVUSUniversal input2 alarm relays
NOVUS N1040i process indicator
Product overview

What is the NOVUS N1040i?

The NOVUS N1040i is a universal process indicator in a 1/16 DIN (48 x 48 mm) case.

  • 01Universal inputThermocouple, Pt100, mA, mV and V.
  • 022 alarm relaysSPDT 3 A and SPST 1.5 A.
  • 03Retransmission0 to 20 or 4 to 20 mA option.
Read more

It accepts thermocouples J, K, T, N, R, S, B and E, Pt100, and 0 to 20 mA, 4 to 20 mA, 0 to 50 mV, 0 to 5 V and 0 to 10 V signals.

Depending on model it has up to two alarm relays, a 0 to 20 or 4 to 20 mA retransmission of the process value, or a 24 Vdc auxiliary supply for a transmitter, and an optional RS485 interface.

Key features

Key Features of the NOVUS N1040i

01 / 06

Universal input

Thermocouples J, K, T, N, R, S, B and E, Pt100, 0 to 20 mA, 4 to 20 mA, 0 to 50 mV, 0 to 5 V and 0 to 10 V.

02 / 06

Alarm relays

Alarm 1 relay SPDT, 240 Vac, 30 Vdc, 3 A; alarm 2 relay SPST, 240 Vac, 30 Vdc, 1.5 A.

03 / 06

Retransmission or supply

Optional 0 to 20 or 4 to 20 mA retransmission (500 Ω max.), or a 24 Vdc auxiliary source, 20 mA max.

04 / 06

Display range

-1999 to 9999 on the display, from 15-bit internal resolution.

05 / 06

RS485 option

An optional RS485 interface on the -485 models.

06 / 06

Compact and sealed

48 x 48 x 80 mm, about 75 g, IP65 front, CE and UL.

Technical specifications

NOVUS N1040i Technical Specifications

Tap a group to filter the process indicator specifications, or show them all.

NOVUS N1040i process indicator
NOVUS N1040i Process Indicator.
  • 0.2 %Accuracyof span, Pt100 and linear
  • 2Alarm relays
  • 48 x 48Panel sizemm
  • IP65Protectionfront
NOVUS N1040i technical specifications
SpecificationDetails
InputsThermocouples J, K, T, N, R, S, B, E; Pt100; 0 to 20 mA, 4 to 20 mA, 0 to 50 mV, 0 to 5 V, 0 to 10 V
AccuracyTC J, K, T, E: 0.25 % of span, 1 °C; TC N, R, S, B: 0.25 % of span, 3 °C; Pt100: 0.2 % of span; mA, mV and V: 0.2 % of span
ResolutionInternal 32767 levels (15 bits); display 12000 levels (-1999 to 9999)

Figures from the NOVUS N1040i brochure. The brochure lists RS485 as the communication option and does not list USB. Confirm the model for your application before ordering.

Download Brochure
How it works

How does the NOVUS N1040i work?

Tap a step, or let it run, to follow the signal from the field to the control system.

Step by step:

The N1040i puts a reading on the panel door and acts on it locally. Alarm relays switch a horn, pump or interlock, and the retransmission option passes the value to a PLC or recorder.

SENSOR0125.4N1040i02ALARM RELAYS03PLC04
NOVUS N1040i: sensor, n1040i, alarm relays, plc
Applications

Where the NOVUS N1040i is used

Typical uses for this process indicator, based on what it does.

  • 01Panel indicationA local display of temperature, pressure, level or flow on a panel door.
  • 02Local alarmsHigh and low alarms through two relays.
  • 03Transmitter supplyPowering a 4 to 20 mA transmitter from the 24 Vdc auxiliary source.
Compare the range

How the NOVUS N1040i compares

Other digital indicators and controllers in our range. The highlighted row is this product. Tap any other name to open its page.

NOVUS N1040i compared with other digital indicators and controllers
ProductTypeSignalsOutputs and communicationSupplyMounting
ACS DPA Digital Display UnitDigital display unit0/4 to 20 mA, 0 to 10 VIsolated analogue out, up to 4 relays, Bluetooth or USB18 to 36 V DC or 186 to 253 VACPanel, field or DIN rail
NOVUS N1050 PID Temperature ControllerPID controllerThermocouple J, K, T, S; Pt100SSR pulse, relays, USB, optional Modbus RTU100 to 240 Vac/dcPanel, 48 x 48 mm
NOVUS N1040i Process IndicatorProcess indicatorThermocouple, Pt100, mA, mV, V2 relays, optional retransmission and RS485100 to 240 Vac or 48 to 240 VdcPanel, 48 x 48 mm
NOVUS N1540 Universal IndicatorUniversal indicatorThermocouple, Pt100, mA, mV, V2 relays, USB, optional Modbus RTU100 to 240 Vac/dcPanel, 96 x 48 mm
NOVUS LoopView Loop-Powered IndicatorLoop-powered indicator4 to 20 mA loopLocal LED displayLoop poweredOn the sensor connector
Proplant PCE

From Selection to a Working Signal in Your Control System

A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.

01 / 04

Application review

We check the signals, channel count, network and mounting before recommending a device.

02 / 04

Supply

Instruments and modules from the brands on this page, with the brochure for your engineering file.

03 / 04

Configuration and installation

Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.

04 / 04

Integration

Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.

Before you order

What to tell us so we can recommend a device

Tick off what you already know. We will check the NOVUS N1040i against your application, or suggest a better fit from our range.

FAQ

NOVUS N1040i FAQ

What is the NOVUS N1040i?

A universal process indicator in a 48 x 48 mm case with up to two alarm relays and optional retransmission.

Which inputs does it accept?

Thermocouples J, K, T, N, R, S, B and E, Pt100, and 0 to 20 mA, 4 to 20 mA, 0 to 50 mV, 0 to 5 V and 0 to 10 V signals.

Can it retransmit the value?

Yes, on the retransmission models it gives a 0 to 20 or 4 to 20 mA output with up to 500 Ω load.

Does it have a communication port?

An RS485 interface is available on the -485 models.

What supply does it need?

100 to 240 Vac or 48 to 240 Vdc, with a maximum of 6 VA.

Can Proplant PCE help me choose the right automation device?

Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.

NOVUS N1040i process indicator

Let's Discuss Your Automation Project

Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.

Scroll to Top