What is the NOVUS N1050?

The NOVUS N1050 is a PID temperature controller with an alphanumeric multicolour LCD display, in a 48 x 48 mm (1/16 DIN) case.

  • 01PID controlThermocouple J, K, T, S and Pt100 input.
  • 02USB set-upFree NConfig software.
  • 03IP65 frontCE, UL and cUL.
Read more

It accepts thermocouples J, K, T and S and Pt100 sensors.

It has a pulse output for an SSR and a relay, up to three optional relays and a soft start function. It is configured over USB with the free NOVUS NConfig software, and RS485 Modbus RTU is available as an option.

Key features

Key Features of the NOVUS N1050

01 / 06

Temperature input

Thermocouples J, K, T and S, and Pt100.

02 / 06

Control outputs

A pulse output for an SSR, a relay, up to three optional relays and a soft start output.

03 / 06

Multicolour LCD

Alphanumeric multicolour LCD display.

04 / 06

USB configuration

Micro-B USB port and the free NOVUS NConfig software.

05 / 06

Modbus option

RS485 Modbus RTU as an option.

06 / 06

Compact panel size

48 x 48 mm (1/16 DIN), IP65, with CE, UL and cUL approval.

Technical specifications

NOVUS N1050 Technical Specifications

Tap a group to filter the PID temperature controller specifications, or show them all.

NOVUS N1050 PID controller, second view
NOVUS N1050 PID controller.
  • 48 x 48Panel sizemm, 1/16 DIN
  • IP65Protection
  • 6 VAConsumptionmax.
  • CE, UL, cULApprovals
NOVUS N1050 technical specifications
SpecificationDetails
InputsThermocouple J, K, T, S and Pt100

Figures from the NOVUS Automation brochure. Confirm the version and options for your application before ordering.

Download Brochure
How it works

How does the NOVUS N1050 work?

Tap a step, or let it run, to follow the signal from the field to the control system.

Step by step:

The N1050 runs the control loop on its own: it reads the sensor, calculates the PID output and switches the heater through an SSR or relay. Alarm relays and Modbus are there when the loop needs to report to a PLC or SCADA.

SENSOR0125.4N105002SSR / RELAY03HEATER04
NOVUS N1050: sensor, n1050, ssr / relay, heater
Applications

Where the NOVUS N1050 is used

Typical uses for this PID temperature controller, based on what it does.

  • 01Heating controlOvens, heaters and baths driven through an SSR or relay.
  • 02Machine temperature controlPanel-mounted control on process machines.
  • 03Temperature alarmsOptional relays for high and low temperature alarms.
Compare the range

How the NOVUS N1050 compares

Other digital indicators and controllers in our range. The highlighted row is this product. Tap any other name to open its page.

NOVUS N1050 compared with other digital indicators and controllers
ProductTypeSignalsOutputs and communicationSupplyMounting
ACS DPA Digital Display UnitDigital display unit0/4 to 20 mA, 0 to 10 VIsolated analogue out, up to 4 relays, Bluetooth or USB18 to 36 V DC or 186 to 253 VACPanel, field or DIN rail
NOVUS N1050 PID Temperature ControllerPID controllerThermocouple J, K, T, S; Pt100SSR pulse, relays, USB, optional Modbus RTU100 to 240 Vac/dcPanel, 48 x 48 mm
NOVUS N1040i Process IndicatorProcess indicatorThermocouple, Pt100, mA, mV, V2 relays, optional retransmission and RS485100 to 240 Vac or 48 to 240 VdcPanel, 48 x 48 mm
NOVUS N1540 Universal IndicatorUniversal indicatorThermocouple, Pt100, mA, mV, V2 relays, USB, optional Modbus RTU100 to 240 Vac/dcPanel, 96 x 48 mm
NOVUS LoopView Loop-Powered IndicatorLoop-powered indicator4 to 20 mA loopLocal LED displayLoop poweredOn the sensor connector
Proplant PCE

From Selection to a Working Signal in Your Control System

A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.

01 / 04

Application review

We check the signals, channel count, network and mounting before recommending a device.

02 / 04

Supply

Instruments and modules from the brands on this page, with the brochure for your engineering file.

03 / 04

Configuration and installation

Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.

04 / 04

Integration

Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.

Before you order

What to tell us so we can recommend a device

Tick off what you already know. We will check the NOVUS N1050 against your application, or suggest a better fit from our range.

FAQ

NOVUS N1050 FAQ

What is the NOVUS N1050?

A PID temperature controller with a multicolour LCD display in a 48 x 48 mm case.

Which sensors can be connected?

Thermocouples J, K, T and S, and Pt100.

What outputs does it have?

A pulse output for an SSR, a relay, up to three optional relays and a soft start output.

How is it configured?

Over USB with the free NOVUS NConfig software, or from the front keys.

Can it connect to a PLC?

Yes, with the optional RS485 Modbus RTU interface.

Can Proplant PCE help me choose the right automation device?

Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.

NOVUS N1050 PID temperature controller

Let's Discuss Your Automation Project

Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.

Scroll to Top