NOVUS N1540 Universal Process Indicator, 96 x 48 mm
A 96 x 48 mm universal indicator with a bright 14 mm display, thermocouple, Pt100 and linear inputs, two alarm relays, USB configuration and optional RS485 Modbus RTU.

Key Features of the NOVUS N1540
Universal input
Thermocouples J, K, T, E, N, R, S and B, Pt100, 0 to 50 mV, 0 to 5 Vdc, 0 to 10 Vdc, 0 to 20 mA and 4 to 20 mA.
Large display
A bright 14 mm display that flashes under an alarm condition.
Alarm relays
Two relay alarms, SPST, 1.5 A at 240 Vac.
Transmitter supply
An auxiliary 24 Vdc source for a field transmitter.
USB configuration
Configuration and monitoring over USB.
Modbus option
RS485 Modbus RTU on the N1540-485-USB.
NOVUS N1540 Technical Specifications
Tap a group to filter the universal indicator specifications, or show them all.

- 96 x 48Panel sizemm
- 14 mmDisplay height
- 2Alarm relays
- IP65Protectionfront
| Specification | Details |
|---|---|
| Inputs | Thermocouples J, K, T, E, N, R, S, B; Pt100; 0 to 50 mV; 0 to 5 Vdc; 0 to 10 Vdc; 0 to 20 mA; 4 to 20 mA |
| Display | Bright 14 mm display; flashes under alarm condition |
| Outputs | Two relay alarms, SPST 1.5 A / 240 Vac |
| Communication | USB (configuration and monitoring); optional RS485 Modbus RTU |
| Models | N1540-USB; N1540-485-USB |
| Mounting | Panel mounting |
| Dimensions | 96 x 48 x 35 mm |
| Panel cutout | 45.5 x 93 mm |
| Auxiliary supply | 24 Vdc |
| Power supply | 100 to 240 Vac/dc ±10 %; option 12 to 24 Vac/dc |
| Protection | IP65 front; IP20 enclosure |
| Approvals | CE and UL |
Figures from the NOVUS Automation brochure. Confirm the version and options for your application before ordering.
Download BrochureHow does the NOVUS N1540 work?
Tap a step, or let it run, to follow the signal from the field to the control system.
Step by step:
The N1540 gives operators a large, clear reading on the panel and raises local alarms. With the RS485 version, the same value goes to a PLC or SCADA over Modbus RTU.
Where the NOVUS N1540 is used
Typical uses for this universal indicator, based on what it does.
- 01Panel indicationA large, readable process value on a control panel.
- 02Local alarmsTwo relays and a flashing display on alarm.
- 03Modbus monitoringValues read by a PLC or SCADA over RS485.
How the NOVUS N1540 compares
Other digital indicators and controllers in our range. The highlighted row is this product. Tap any other name to open its page.
| Product | Type | Signals | Outputs and communication | Supply | Mounting |
|---|---|---|---|---|---|
| ACS DPA Digital Display Unit | Digital display unit | 0/4 to 20 mA, 0 to 10 V | Isolated analogue out, up to 4 relays, Bluetooth or USB | 18 to 36 V DC or 186 to 253 VAC | Panel, field or DIN rail |
| NOVUS N1050 PID Temperature Controller | PID controller | Thermocouple J, K, T, S; Pt100 | SSR pulse, relays, USB, optional Modbus RTU | 100 to 240 Vac/dc | Panel, 48 x 48 mm |
| NOVUS N1040i Process Indicator | Process indicator | Thermocouple, Pt100, mA, mV, V | 2 relays, optional retransmission and RS485 | 100 to 240 Vac or 48 to 240 Vdc | Panel, 48 x 48 mm |
| NOVUS N1540 Universal Indicator | Universal indicator | Thermocouple, Pt100, mA, mV, V | 2 relays, USB, optional Modbus RTU | 100 to 240 Vac/dc | Panel, 96 x 48 mm |
| NOVUS LoopView Loop-Powered Indicator | Loop-powered indicator | 4 to 20 mA loop | Local LED display | Loop powered | On the sensor connector |
From Selection to a Working Signal in Your Control System
A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.
Application review
We check the signals, channel count, network and mounting before recommending a device.
Supply
Instruments and modules from the brands on this page, with the brochure for your engineering file.
Configuration and installation
Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.
Integration
Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.
What to tell us so we can recommend a device
Tick off what you already know. We will check the NOVUS N1540 against your application, or suggest a better fit from our range.
Other automation products to consider
NOVUS N1540 FAQ
What is the NOVUS N1540?
A 96 x 48 mm universal indicator with a 14 mm display, two alarm relays and USB configuration.
Which inputs does it accept?
Thermocouples J, K, T, E, N, R, S and B, Pt100, mV, 0 to 5 and 0 to 10 Vdc, and 0 to 20 or 4 to 20 mA.
Can it communicate with a PLC?
Yes. The N1540-485-USB has RS485 Modbus RTU.
What is the panel cutout?
45.5 x 93 mm.
What supply does it need?
100 to 240 Vac/dc, or 12 to 24 Vac/dc as an option.
Can Proplant PCE help me choose the right automation device?
Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.
Let's Discuss Your Automation Project
Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.