ACS DPA Digital Display Unit with Relays, Isolated Output and Data Logger
A digital display unit that shows, processes and galvanically separates standard 0 to 10 V and 0/4 to 20 mA signals, with an isolated analogue output, up to 4 relays and an optional data logger.

Key Features of the ACS DPA
Standard signal input
0/4 to 20 mA and 0 to 10 V, with a transmitter supply of 0 to 28 mA.
Isolated analogue output
0 to 10 V or 0/4 to 20 mA, galvanically separated from the input.
Relays and digital inputs
2 relays on types B and T, 4 on types D and U, with digital inputs to IEC 61131-2.
Data logger
Time-stamped, battery-powered logging of up to 500,000 readings on variants 2 and 3.
Bluetooth or USB
Bluetooth 2.0 or USB 2.0-A, depending on variant.
Hazardous area options
ATEX II (1) G [Ex ia Ga] IIC or II (1) D [Ex ia Da] IIIC with approval option X.
ACS DPA Technical Specifications
Tap a group to filter the digital display unit specifications, or show them all.

- ≤ 0.2 %Accuracy
- 4Relaystypes D and U
- 500,000Logged readingsvariants 2 and 3
- IP65Protectionwall and DIN rail housing
| Specification | Details |
|---|---|
| Analogue input | 0/4 to 20 mA and 0 to 10 V |
| Accuracy | ≤ 0.2 %; characteristic deviation ≤ ±0.05 % FS; temperature deviation ≤ ±0.1 % FS / 10 K |
| Display | Full colour TFT |
| Analogue output | 0 to 10 V or 0/4 to 20 mA |
| Relays | Potential-free changeover contacts: types B and T 2, types D and U 4 |
| Digital inputs | InD1 to 4 on types B, D, T and U (IEC 61131-2) |
| Interfaces | Bluetooth 2.0 Full Speed or USB 2.0-A, depending on variant |
| Data logger | With time stamp, battery powered (variants 2 and 3), up to 500,000 readings |
| Mounting | Front panel (type M), field enclosure (type F), DIN rail (type P) |
| Transmitter supply | 0 to 28 mA |
| Power supply | Types A, B, D: 18 to 36 V DC, reverse polarity protected (≤ 5 W); types S, T, U: 186 to 253 VAC (≤ 20 VA) |
| Ambient temperature | -20 to +50 °C |
| Protection | Wall-mount and DIN rail IP65; front panel IP54 front, IP20 rear (IP65 front with option) |
| Approvals | ATEX II (1) G [Ex ia Ga] IIC or ATEX II (1) D [Ex ia Da] IIIC (option X) |
Figures from the ACS-Control-System brochure. Confirm the version and options for your application before ordering.
Download BrochureHow does the ACS DPA work?
Tap a step, or let it run, to follow the signal from the field to the control system.
Step by step:
The DPA shows the value in engineering units where operators can see it, acts on limits with its relays, and passes an isolated copy of the signal on to the control system. The ATEX versions isolate signals coming from a hazardous area.
Where the ACS DPA is used
Typical applications for this digital display unit, from the manufacturer's documentation.
- 01Tank contentsLinearising non-linear inputs, such as horizontal cylindrical tanks.
- 02Flow and currentDetection and measurement of flow rates and currents.
- 03Signal isolationGalvanic isolation of signals, including from hazardous areas.
How the ACS DPA compares
Other digital indicators and controllers in our range. The highlighted row is this product. Tap any other name to open its page.
| Product | Type | Signals | Outputs and communication | Supply | Mounting |
|---|---|---|---|---|---|
| ACS DPA Digital Display Unit | Digital display unit | 0/4 to 20 mA, 0 to 10 V | Isolated analogue out, up to 4 relays, Bluetooth or USB | 18 to 36 V DC or 186 to 253 VAC | Panel, field or DIN rail |
| NOVUS N1050 PID Temperature Controller | PID controller | Thermocouple J, K, T, S; Pt100 | SSR pulse, relays, USB, optional Modbus RTU | 100 to 240 Vac/dc | Panel, 48 x 48 mm |
| NOVUS N1040i Process Indicator | Process indicator | Thermocouple, Pt100, mA, mV, V | 2 relays, optional retransmission and RS485 | 100 to 240 Vac or 48 to 240 Vdc | Panel, 48 x 48 mm |
| NOVUS N1540 Universal Indicator | Universal indicator | Thermocouple, Pt100, mA, mV, V | 2 relays, USB, optional Modbus RTU | 100 to 240 Vac/dc | Panel, 96 x 48 mm |
| NOVUS LoopView Loop-Powered Indicator | Loop-powered indicator | 4 to 20 mA loop | Local LED display | Loop powered | On the sensor connector |
From Selection to a Working Signal in Your Control System
A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.
Application review
We check the signals, channel count, network and mounting before recommending a device.
Supply
Instruments and modules from the brands on this page, with the brochure for your engineering file.
Configuration and installation
Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.
Integration
Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.
What to tell us so we can recommend a device
Tick off what you already know. We will check the ACS DPA against your application, or suggest a better fit from our range.
Other automation products to consider
ACS DPA FAQ
What is the ACS DPA?
A digital display unit from ACS-Control-System that displays, processes and isolates 0 to 10 V and 0/4 to 20 mA signals, with relays and an optional data logger.
How many relays does it have?
Two potential-free changeover relays on types B and T, and four on types D and U.
Can it be used with hazardous area signals?
Yes. Approval option X gives ATEX II (1) G [Ex ia Ga] IIC or II (1) D [Ex ia Da] IIIC.
How is it mounted?
In a front panel, in a field enclosure or on a DIN rail, depending on the type ordered.
Can it log data?
Variants 2 and 3 include a battery-powered, time-stamped data logger for up to 500,000 readings.
Can Proplant PCE help me choose the right automation device?
Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.
Let's Discuss Your Automation Project
Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.