Proplant PCE

Digital display unit

ACS DPA Digital Display Unit with Relays, Isolated Output and Data Logger

A digital display unit that shows, processes and galvanically separates standard 0 to 10 V and 0/4 to 20 mA signals, with an isolated analogue output, up to 4 relays and an optional data logger.

ACS-Control-SystemUp to 4 relaysATEX options
ACS DPA digital display unit
Product overview

What is the ACS DPA?

The ACS DPA is a digital display unit for the display, processing, implementation and galvanic separation of standard electrical signals, 0 to 10 V and 0/4 to 20 mA.

  • 01Display and processFull colour TFT display.
  • 02Up to 4 relaysPotential-free changeover contacts.
  • 03Data loggerUp to 500,000 time-stamped readings.
Read more

It has a full colour TFT display.

Depending on type it adds digital inputs, an isolated 0 to 10 V or 0/4 to 20 mA output, 2 or 4 potential-free relays, a battery-backed data logger for up to 500,000 readings, and Bluetooth or USB. It is available for panel front, field enclosure or DIN rail mounting, with ATEX intrinsic safety options.

Key features

Key Features of the ACS DPA

01 / 06

Standard signal input

0/4 to 20 mA and 0 to 10 V, with a transmitter supply of 0 to 28 mA.

02 / 06

Isolated analogue output

0 to 10 V or 0/4 to 20 mA, galvanically separated from the input.

03 / 06

Relays and digital inputs

2 relays on types B and T, 4 on types D and U, with digital inputs to IEC 61131-2.

04 / 06

Data logger

Time-stamped, battery-powered logging of up to 500,000 readings on variants 2 and 3.

05 / 06

Bluetooth or USB

Bluetooth 2.0 or USB 2.0-A, depending on variant.

06 / 06

Hazardous area options

ATEX II (1) G [Ex ia Ga] IIC or II (1) D [Ex ia Da] IIIC with approval option X.

Technical specifications

ACS DPA Technical Specifications

Tap a group to filter the digital display unit specifications, or show them all.

ACS DPA digital display unit in the panel-mount housing
ACS DPA in the panel-mount housing.
  • ≤ 0.2 %Accuracy
  • 4Relaystypes D and U
  • 500,000Logged readingsvariants 2 and 3
  • IP65Protectionwall and DIN rail housing
ACS DPA technical specifications
SpecificationDetails
Analogue input0/4 to 20 mA and 0 to 10 V
Accuracy≤ 0.2 %; characteristic deviation ≤ ±0.05 % FS; temperature deviation ≤ ±0.1 % FS / 10 K

Figures from the ACS-Control-System brochure. Confirm the version and options for your application before ordering.

Download Brochure
How it works

How does the ACS DPA work?

Tap a step, or let it run, to follow the signal from the field to the control system.

Step by step:

The DPA shows the value in engineering units where operators can see it, acts on limits with its relays, and passes an isolated copy of the signal on to the control system. The ATEX versions isolate signals coming from a hazardous area.

TRANSMITTER0125.4ACS DPA02RELAYS03PLC04
ACS DPA: transmitter, acs dpa, relays, plc
Applications

Where the ACS DPA is used

Typical applications for this digital display unit, from the manufacturer's documentation.

  • 01Tank contentsLinearising non-linear inputs, such as horizontal cylindrical tanks.
  • 02Flow and currentDetection and measurement of flow rates and currents.
  • 03Signal isolationGalvanic isolation of signals, including from hazardous areas.
Compare the range

How the ACS DPA compares

Other digital indicators and controllers in our range. The highlighted row is this product. Tap any other name to open its page.

ACS DPA compared with other digital indicators and controllers
ProductTypeSignalsOutputs and communicationSupplyMounting
ACS DPA Digital Display UnitDigital display unit0/4 to 20 mA, 0 to 10 VIsolated analogue out, up to 4 relays, Bluetooth or USB18 to 36 V DC or 186 to 253 VACPanel, field or DIN rail
NOVUS N1050 PID Temperature ControllerPID controllerThermocouple J, K, T, S; Pt100SSR pulse, relays, USB, optional Modbus RTU100 to 240 Vac/dcPanel, 48 x 48 mm
NOVUS N1040i Process IndicatorProcess indicatorThermocouple, Pt100, mA, mV, V2 relays, optional retransmission and RS485100 to 240 Vac or 48 to 240 VdcPanel, 48 x 48 mm
NOVUS N1540 Universal IndicatorUniversal indicatorThermocouple, Pt100, mA, mV, V2 relays, USB, optional Modbus RTU100 to 240 Vac/dcPanel, 96 x 48 mm
NOVUS LoopView Loop-Powered IndicatorLoop-powered indicator4 to 20 mA loopLocal LED displayLoop poweredOn the sensor connector
Proplant PCE

From Selection to a Working Signal in Your Control System

A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.

01 / 04

Application review

We check the signals, channel count, network and mounting before recommending a device.

02 / 04

Supply

Instruments and modules from the brands on this page, with the brochure for your engineering file.

03 / 04

Configuration and installation

Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.

04 / 04

Integration

Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.

Before you order

What to tell us so we can recommend a device

Tick off what you already know. We will check the ACS DPA against your application, or suggest a better fit from our range.

FAQ

ACS DPA FAQ

What is the ACS DPA?

A digital display unit from ACS-Control-System that displays, processes and isolates 0 to 10 V and 0/4 to 20 mA signals, with relays and an optional data logger.

How many relays does it have?

Two potential-free changeover relays on types B and T, and four on types D and U.

Can it be used with hazardous area signals?

Yes. Approval option X gives ATEX II (1) G [Ex ia Ga] IIC or II (1) D [Ex ia Da] IIIC.

How is it mounted?

In a front panel, in a field enclosure or on a DIN rail, depending on the type ordered.

Can it log data?

Variants 2 and 3 include a battery-powered, time-stamped data logger for up to 500,000 readings.

Can Proplant PCE help me choose the right automation device?

Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.

ACS DPA digital display unit

Let's Discuss Your Automation Project

Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.

Scroll to Top