Proplant PCE

Condition monitoring

Balluff BCM Condition Monitoring Sensors for Vibration and Temperature

Compact IO-Link sensors that measure 3-axis vibration and contact temperature on motors, pumps and fans, so faults show before they stop the plant.

Balluff3-axis vibrationIO-Link
Balluff BCM0001 condition monitoring sensor with M12 cable
Product overview

What is the Balluff BCM sensor?

Balluff's condition monitoring sensors record physical variables such as vibration, temperature, humidity and air pressure.

  • 013 axesVibration on three measuring axes.
  • 02Up to 6000 HzBCM0004 frequency range (±3 dB).
  • 03IO-LinkValues and diagnostics to the control system.
Read more

Balluff says they make a significant contribution to the efficient and trouble-free operation of every plant.

The BCM R series has a stainless steel housing and a 1.5 m PUR cable with an M12 connector. BCM0001 measures vibration and contact temperature, BCM0002 adds humidity and air pressure, and BCM0004 extends the vibration range to 6000 Hz.

Key features

Key Features of the Balluff BCM sensor

01 / 06

Vibration and temperature

BCM0001: 3-axis vibration, -16 to 16 g, 2 to 2500 Hz (±3 dB), and contact temperature from -25 to +70 °C.

02 / 06

Ambient conditions too

BCM0002 adds relative humidity (5 to 95 %RH) and ambient pressure (300 to 1100 hPa).

03 / 06

Wider range

BCM0004: 2 to 6000 Hz (±3 dB) and contact temperature from -40 to +80 °C.

04 / 06

Device data

BCM0004 adds operating hours, boot cycle and switching counters, voltage and current monitoring, and internal temperature.

05 / 06

Robust housing

1.4404 stainless steel; IP67, IP68 and IP69K on BCM0001 and BCM0004.

06 / 06

IO-Link

IO-Link 1.1 (BCM0001, BCM0002) and 1.1.3 (BCM0004).

Technical specifications

Balluff BCM sensor Technical Specifications

Tap a group to filter the condition monitoring sensor specifications, or show them all.

Balluff BCM0004 condition monitoring sensor, sensing face
Balluff BCM0004 condition monitoring sensor.
  • 3Axesvibration
  • ±16gmeasuring range
  • 6000HzBCM0004, ±3 dB
  • IP69KProtectionBCM0001, BCM0004
Balluff BCM sensor technical specifications
SpecificationDetails
FunctionsBCM0001, BCM0004: vibration analysis in time domain, contact temperature. BCM0002: also relative humidity and ambient pressure
Vibration, measuring range-16 to 16 g, 3 axes
Vibration, frequency rangeBCM0001, BCM0002: 2 to 1800 Hz (±10 %), 2 to 2500 Hz (±3 dB). BCM0004: 2 to 4500 Hz (±10 %), 2 to 6000 Hz (±3 dB)
Contact temperatureBCM0001, BCM0002: -25 to +70 °C. BCM0004: -40 to +80 °C
Humidity and pressure (BCM0002)5 to 95 %RH; 300 to 1100 hPa

Figures from the Balluff product page for each model, read in November 2026. Confirm the frequency range and mounting for your machine before ordering.

Brochure and data sheets
How it works

How does the Balluff BCM sensor work?

Tap a step, or let it run, to follow the signal from the field to the control system.

Step by step:

The BCM is fixed to the machine and measures vibration on three axes and the temperature of the surface it sits on. It sends these values over IO-Link, so the control system can watch them over time and warn when a bearing, mounting or load starts to change, before it becomes a breakdown.

MOTOR OR PUMP01BCM SENSOR02IO-LINK MASTER03SCADA04
Balluff BCM sensor: motor or pump, bcm sensor, io-link master, scada
Applications

Where the Balluff BCM sensor is used

Typical applications for this condition monitoring sensor, from the manufacturer's documentation.

  • 01Machine vibrationMonitoring motors, pumps and fans for vibration on three axes.
  • 02TemperatureWatching the contact temperature of the machine surface.
  • 03Predictive maintenanceTrend data over IO-Link to plan maintenance.
Compare the range

How the Balluff BCM sensor compares

Other io-link and balluff in our range. The highlighted row is this product. Tap any other name to open its page.

Balluff BCM sensor compared with other io-link and balluff
ProductTypeSignalsOutputs and communicationSupplyMounting
Balluff Multiprotocol IO-Link MastersIO-Link master8 IO-Link portsPROFINET, EtherNet/IP, EtherCAT, Modbus TCP18 to 30 VDCMachine, IP67 to IP69K
Balluff IO-Link Sensor and Actuator HubsIO-Link hub16 DI and 16 DO, or 8 analogue inIO-Link to one master port18 to 30.2 VDCMachine, IP67
Balluff IO-Link SensorsIO-Link sensorsInductive, optical, capacitive, magnetic, distance, pressureIO-Link 1.1 plus switching or analogue10 to 30 VDC, model dependentMachine and process
Balluff Condition Monitoring SensorsCondition monitoring sensor3-axis vibration, contact temperatureIO-Link24 V DCMachine mount, IP67 to IP69K
autosen AS005 IO-Link Flow SensorThermal flow sensorFlow and temperature, liquids and gases2 switching, 4 to 20 mA, IO-Link18 to 30 V DCM18 x 1.5 adapter, IP65 and IP67
Balluff IO-Link Safety HubSafety I/O hub12 safe inputs, 2 safe outputsPROFIsafe over IO-Link19.2 to 30 VMachine, IP67
Balluff Heartbeat Power Supplies with IO-Link24 V power supply192 to 360 WIO-Link diagnostics85 to 264 V AC in, model dependentDIN rail IP20 or field IP67
Balluff M12 Cordsets and SplittersM12 cordsetsSingle, double-ended, Y-splitter, NAMURSensor and power cable250 VDC / 250 VAC, 4 AIP67 to IP69K
Proplant PCE

From Selection to a Working Signal in Your Control System

A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.

01 / 04

Application review

We check the signals, channel count, network and mounting before recommending a device.

02 / 04

Supply

Instruments and modules from the brands on this page, with the brochure for your engineering file.

03 / 04

Configuration and installation

Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.

04 / 04

Integration

Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.

Before you order

What to tell us so we can recommend a device

Tick off what you already know. We will check the Balluff BCM sensor against your application, or suggest a better fit from our range.

FAQ

Balluff BCM sensor FAQ

What does a condition monitoring sensor measure?

The BCM measures vibration on three axes and contact temperature. BCM0002 also measures relative humidity and ambient pressure.

Which model has the widest vibration range?

BCM0004, from 2 to 6000 Hz (±3 dB).

How does the data reach the control system?

Over IO-Link, through an IO-Link master such as the Balluff multiprotocol IO-Link master.

Is it suitable for washdown areas?

BCM0001 and BCM0004 are rated IP67, IP68 and IP69K, with a stainless steel housing.

Can Proplant PCE help me choose the right automation device?

Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.

Balluff BCM sensor condition monitoring sensor

Let's Discuss Your Automation Project

Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.

Scroll to Top