Proplant PCE

IO-Link power supplies

Balluff Heartbeat IO-Link Power Supply Units, 24 V DC

An IO-Link power supply that delivers 24 V DC to sensors, actuators and controllers and reports its own status and diagnostics, in the cabinet or the field.

Balluff24 V DCIO-Link diagnostics
Balluff BAE00LJ IO-Link power supply for DIN rail
Product overview

What is the Balluff Heartbeat power supply?

A Balluff Heartbeat IO-Link power supply delivers 24 V DC to sensors, actuators, controllers and HMIs.

  • 0124 V DCRated output on all three units.
  • 02Cabinet or fieldIP20 DIN rail or IP67 flange mount.
  • 03IO-LinkStatus and diagnostics to the control system.
Read more

Balluff says they were developed for critical applications with high demands on quality and long service life.

Through IO-Link the control system can call up detailed diagnostic and status information about the supply. We supply a DIN rail unit for the cabinet and two IP67 units that mount in the field, close to the loads.

Key features

Key Features of the Balluff Heartbeat power supply

01 / 06

Cabinet unit

BAE00LJ: DIN rail, 115/230 VAC automatic selection, 24 V at 10 A, 240 W, IP20.

02 / 06

Field unit

BAE00TL: flange mount, 100 to 240 V AC, 24 V at 8 A, 192 W, IP67 with 7/8" connectors.

03 / 06

Higher power in the field

BAE012M: 85 to 264 V AC in, 24 to 28 V DC out at 15 A, 360 W, IP67/IP65.

04 / 06

Power reserve

BAE00LJ delivers 15 A for up to 4 s, once a minute.

BAE00TL delivers 12 A for up to 4 s.

05 / 06

Diagnostics over IO-Link

Status and diagnostic data for maintenance planning.

06 / 06

Wide temperature range

-25 to 70 °C ambient on all three units.

Technical specifications

Balluff Heartbeat power supply Technical Specifications

Tap a group to filter the IO-Link power supply specifications, or show them all.

Balluff BAE00TL IP67 IO-Link power supply
Balluff BAE00TL, IP67 field power supply.
  • 24V DCrated output
  • 192 to 360Woutput capacity
  • IP67Protectionfield units
  • -25 to 70°Cambient
Balluff Heartbeat power supply technical specifications
SpecificationDetails
BAE00LJ (BAE PS-XA-1S-24-100-103)DIN rail; input 115/230 VAC automatic selection, single phase; output 24 V DC, 10 A rated, 240 W max., 15 A for max. 4 s, 1x/min.
BAE00TL (BAE PS-XA-1W-24-080-604-I)IP67 flange mount; input 100 to 240 V AC, 1-phase; output 24 V DC, 8 A rated, 192 W max., 12 A for max. 4 s
BAE012M (BAE PS-XA-1W-24-150-608-I)Flange mount; input 85 to 264 V AC; output 24 to 28 V DC, 15 A rated, 360 W max.

Figures from the Balluff product page for each model, read in November 2026. Balluff lists all three as Heartbeat power supply units with IO-Link interface. Confirm input voltage and load before ordering.

Data sheets by model
How it works

How does the Balluff Heartbeat power supply work?

Tap a step, or let it run, to follow the signal from the field to the control system.

Step by step:

An IO-Link power supply converts mains AC to 24 V DC for sensors, actuators and controllers. Its IO-Link connection to a master port carries status and diagnostic data, so the control system can see how the supply is running and plan maintenance before a fault stops the machine.

MAINS POWER01POWER SUPPLY02IO-LINK MASTER03SCADA04
Balluff Heartbeat power supply: mains power, power supply, io-link master, scada
Applications

Where the Balluff Heartbeat power supply is used

Typical applications for this IO-Link power supply, from the manufacturer's documentation.

  • 0124 V supplyPowering sensors, actuators, controllers and HMIs.
  • 02Decentralised machinesIP67 units that supply modules in the field, close to the consumer.
  • 03Predictive maintenanceStatus and diagnostic data over IO-Link.
Compare the range

How the Balluff Heartbeat power supply compares

Other io-link and balluff in our range. The highlighted row is this product. Tap any other name to open its page.

Balluff Heartbeat power supply compared with other io-link and balluff
ProductTypeSignalsOutputs and communicationSupplyMounting
Balluff Multiprotocol IO-Link MastersIO-Link master8 IO-Link portsPROFINET, EtherNet/IP, EtherCAT, Modbus TCP18 to 30 VDCMachine, IP67 to IP69K
Balluff IO-Link Sensor and Actuator HubsIO-Link hub16 DI and 16 DO, or 8 analogue inIO-Link to one master port18 to 30.2 VDCMachine, IP67
Balluff IO-Link SensorsIO-Link sensorsInductive, optical, capacitive, magnetic, distance, pressureIO-Link 1.1 plus switching or analogue10 to 30 VDC, model dependentMachine and process
Balluff Condition Monitoring SensorsCondition monitoring sensor3-axis vibration, contact temperatureIO-Link24 V DCMachine mount, IP67 to IP69K
autosen AS005 IO-Link Flow SensorThermal flow sensorFlow and temperature, liquids and gases2 switching, 4 to 20 mA, IO-Link18 to 30 V DCM18 x 1.5 adapter, IP65 and IP67
Balluff IO-Link Safety HubSafety I/O hub12 safe inputs, 2 safe outputsPROFIsafe over IO-Link19.2 to 30 VMachine, IP67
Balluff Heartbeat Power Supplies with IO-Link24 V power supply192 to 360 WIO-Link diagnostics85 to 264 V AC in, model dependentDIN rail IP20 or field IP67
Balluff M12 Cordsets and SplittersM12 cordsetsSingle, double-ended, Y-splitter, NAMURSensor and power cable250 VDC / 250 VAC, 4 AIP67 to IP69K
Proplant PCE

From Selection to a Working Signal in Your Control System

A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.

01 / 04

Application review

We check the signals, channel count, network and mounting before recommending a device.

02 / 04

Supply

Instruments and modules from the brands on this page, with the brochure for your engineering file.

03 / 04

Configuration and installation

Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.

04 / 04

Integration

Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.

Before you order

What to tell us so we can recommend a device

Tick off what you already know. We will check the Balluff Heartbeat power supply against your application, or suggest a better fit from our range.

FAQ

Balluff Heartbeat power supply FAQ

What does an IO-Link power supply add?

The control system can call up detailed diagnostic and status information about the supply through an IO-Link master.

Which unit goes in a control cabinet?

BAE00LJ, a 240 W DIN rail unit rated IP20.

Can a supply be mounted on the machine?

Yes. BAE00TL (192 W) and BAE012M (360 W) are flange-mounted units rated IP67 with 7/8" connectors.

What output voltage do they give?

24 V DC. BAE012M can be set from 24 to 28 V DC.

Can Proplant PCE help me choose the right automation device?

Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.

Balluff Heartbeat power supply IO-Link power supply

Let's Discuss Your Automation Project

Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.