Proplant PCE

Digital to Ethernet

Acromag 981EN, 982EN and 983EN 12-Channel Discrete Ethernet I/O

12-channel discrete Ethernet I/O modules: inputs on the 981EN, outputs on the 982EN and both on the 983EN, communicating by Modbus TCP/IP or EtherNet/IP with no software needed.

Acromag12 discrete channelsNo software needed
Acromag 983EN discrete Ethernet I/O module
Product overview

What is the Acromag 98xEN?

The Acromag 981EN, 982EN and 983EN are 12-channel discrete I/O modules for Ethernet.

  • 0112 channelsInputs, outputs or both.
  • 02500 mA outputsPer channel, continuous.
  • 03Failsafe modesOff, last state or pre-defined.
Read more

The 981EN has 12 inputs, the 982EN 12 outputs and the 983EN 12 channels that can be inputs or outputs, with active-low inputs and sinking outputs.

The -4012 models use Modbus TCP/IP and the -6012 models EtherNet/IP, with a PCCC object for legacy PLCs. They are configured from a built-in web page, and outputs have three selectable failsafe modes.

Key features

Key Features of the Acromag 98xEN

01 / 06

Input, output or both

981EN 12 inputs, 982EN 12 outputs, 983EN 12 bidirectional channels.

02 / 06

Discrete inputs

12 active-low, buffered inputs, 0 to 35 V DC, TTL-compatible threshold with about 100 mV hysteresis.

03 / 06

Sinking outputs

12 open-drain MOSFET outputs, 0 to 35 V DC, 0 to 500 mA per channel continuous.

04 / 06

Failsafe outputs

Three selectable modes on loss of communication: off, last state or pre-defined.

05 / 06

Modbus TCP or EtherNet/IP

-4012 Modbus TCP/IP, -6012 EtherNet/IP with a PCCC object for legacy PLCs, conformance tested.

06 / 06

No software

Configured from a built-in web page.

Technical specifications

Acromag 98xEN Technical Specifications

Tap a group to filter the digital to Ethernet module specifications, or show them all.

Acromag 983EN discrete Ethernet I/O module
Acromag 981EN, 982EN and 983EN Discrete Ethernet I/O.
  • 12Channelsdiscrete
  • 500 mAOutput currentper channel
  • 1500 V ACIsolation3-way
  • -25 to 70 °COperating temperature
Acromag 98xEN technical specifications
SpecificationDetails
Inputs12 active-low, buffered, common connection; 0 to 35 V DC; about 100 kΩ; TTL-compatible threshold, about 100 mV hysteresis; 5.6 kΩ socketed pull-ups

Figures from the Acromag brochure. Confirm the version and options for your application before ordering.

Download Brochure
How it works

How does the Acromag 98xEN work?

Tap a step, or let it run, to follow the signal from the field to the control system.

Step by step:

The 98xEN modules collect on/off signals and drive outputs at a remote point, and talk to the control system over Ethernet. If the network is lost, outputs go to the failsafe state you selected.

CONTACTS01983EN02ETHERNET03PLC / SCADA04
Acromag 98xEN: contacts, 983en, ethernet, plc / scada
Applications

Where the Acromag 98xEN is used

Typical applications for this digital to Ethernet module, from the manufacturer's documentation.

  • 01Remote monitoringProcess and discrete device states at remote sites.
  • 02Motor and contactor statusRemote monitoring of motor loads and contactor status.
  • 03Pump and valve controlTank level, pump and valve control.
  • 04Utility monitoringPower and water utility monitoring.
  • 05Remote switching stationsRemote control switching stations.
  • 06Alarm and annunciator systemsProcess shutdown, alarming and annunciator systems.
Compare the range

How the Acromag 98xEN compares

Other signal converters and isolators in our range. The highlighted row is this product. Tap any other name to open its page.

Acromag 98xEN compared with other signal converters and isolators
ProductTypeSignalsOutputs and communicationSupplyMounting
Acromag BusWorks XT1540 Ethernet I/O ModuleEthernet I/O4 discrete I/O8 analogue out; Modbus TCP, EtherNet/IP or PROFINET12 to 32 V DCDIN rail, 22.5 mm
Acromag 961EN and 962EN Analogue Input Ethernet I/OEthernet I/O6 differential current or voltage inputsModbus TCP or EtherNet/IP15 to 36 V DCDIN rail
Acromag 981EN, 982EN and 983EN Discrete Ethernet I/OEthernet I/O12 discrete inputs, outputs or bothModbus TCP or EtherNet/IP15 to 36 V DCDIN rail
Datexel DAT 511 Loop-Powered Current IsolatorLoop isolator0 to 20 mAIsolated 0 to 20 mALoop poweredDIN rail, 17 mm
Datexel DAT 4135 Isolated Universal Signal ConverterUniversal converterRTD, TC, mV, V, mA, resistanceIsolated current or voltage18 to 30 VdcDIN rail
Datexel DAT 4035 Loop-Powered Universal TransmitterUniversal transmitterRTD, TC, mV, V, mA, resistanceIsolated 4 to 20 mA loopLoop powered, 10 to 32 VdcDIN rail
Proplant PCE

From Selection to a Working Signal in Your Control System

A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.

01 / 04

Application review

We check the signals, channel count, network and mounting before recommending a device.

02 / 04

Supply

Instruments and modules from the brands on this page, with the brochure for your engineering file.

03 / 04

Configuration and installation

Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.

04 / 04

Integration

Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.

Before you order

What to tell us so we can recommend a device

Tick off what you already know. We will check the Acromag 98xEN against your application, or suggest a better fit from our range.

FAQ

Acromag 98xEN FAQ

What is the difference between the 981EN, 982EN and 983EN?

The 981EN has 12 discrete inputs, the 982EN 12 discrete outputs, and the 983EN 12 channels that work as inputs or outputs.

Which protocols do they support?

Modbus TCP/IP on the -4012 models and EtherNet/IP on the -6012 models, which also have a PCCC object for legacy PLCs.

How much current can the outputs switch?

Up to 500 mA per channel continuous, at 0 to 35 V DC.

What happens if the network is lost?

Outputs go to one of three selectable failsafe states: off, last state or a pre-defined state.

Do they need software?

No. They are configured from a built-in web page.

Can Proplant PCE help me choose the right automation device?

Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.

Acromag 98xEN digital to Ethernet module

Let's Discuss Your Automation Project

Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.

Scroll to Top