A two-wire isolated universal transmitter that turns RTD, thermocouple, resistance, potentiometer, mV, V and mA signals into a 4 to 20 mA loop signal, programmed from a PC.

DatexelLoop powered2000 Vac isolation
Datexel DAT 4035 universal transmitter
Product overview

What is the Datexel DAT 4035?

The Datexel DAT 4035 is a two-wire isolated universal transmitter for the DIN rail.

  • 01Universal inputTC, RTD, resistance, mV, V and mA.
  • 02Loop powered10 to 32 Vdc, 4 to 20 mA output.
  • 032000 VacIsolation, 1 minute.
Read more

It measures thermocouples, RTDs in 2, 3 or 4 wires, resistance, potentiometers, mV, V and mA, and converts them to a 4 to 20 mA current loop.

It is powered by the loop at 10 to 32 Vdc, isolates the input from the supply and output at 2000 Vac, and is programmed with the PROSOFT software through the PRODAT interface.

Key features

Key Features of the Datexel DAT 4035

01 / 06

Thermocouple and RTD

Thermocouples J, K, S, R, B, E, T and N; RTDs Pt100, Pt1000, Ni100 and Ni1000 in 2, 3 or 4 wires.

02 / 06

Linear signals

Resistance 0 to 300 Ω and 0 to 2000 Ω, potentiometer, mV -400 to +400 and -100 to +700, V -10 to +10 and mA -10 to +24.

03 / 06

4 to 20 mA loop output

A configurable 4 to 20 mA current loop output.

04 / 06

Isolation

2000 Vac, 50 Hz for 1 minute, input to supply and output.

05 / 06

PC programming

PROSOFT software through the PRODAT interface.

06 / 06

Accuracy

Linearity TC ±0.2 % and RTD ±0.1 % of full scale; thermal drift ±0.01 % per °C.

Technical specifications

Datexel DAT 4035 Technical Specifications

Tap a group to filter the universal transmitter specifications, or show them all.

Datexel DAT 4035 wiring diagram
DAT 4035 wiring diagram.
  • 2000 VacIsolation1 min
  • ±0.1 %RTD linearityof full scale
  • 10 to 32 VdcLoop supply
  • -20 to +70 °COperating temperature
Datexel DAT 4035 technical specifications
SpecificationDetails
Thermocouple inputsJ, K, S, R, B, E, T, N
RTD inputsPt100, Pt1000, Ni100, Ni1000 (2, 3 or 4 wires)
Other inputsResistance 0 to 300 Ω and 0 to 2000 Ω; potentiometer; mV -400 to +400 and -100 to +700; V -10 to +10; mA -10 to +24
AccuracyLinearity TC ±0.2 % f.s., RTD ±0.1 % f.s.; thermal drift ±0.01 % / °C

Figures from the Datexel DAT 4035 brochure. The brochure gives 2000 Vac isolation and PC configuration. Confirm the version for your application before ordering.

Download Brochure
How it works

How does the Datexel DAT 4035 work?

Tap a step, or let it run, to follow the signal from the field to the control system.

Step by step:

The DAT 4035 takes its power from the 4 to 20 mA loop, so it needs only the two loop wires. It suits panels where sensors of different types all have to arrive at the PLC as standard 4 to 20 mA signals.

SENSOR01DAT 403502ISOLATION03PLC04
Datexel DAT 4035: sensor, dat 4035, isolation, plc
Applications

Where the Datexel DAT 4035 is used

Typical uses for this universal transmitter, based on what it does.

  • 01Temperature to 4 to 20 mARTDs and thermocouples converted on the DIN rail.
  • 02Potentiometer positionPosition feedback converted to a loop signal.
  • 03Isolated loopsIsolation between the sensor circuit and the loop.
Compare the range

How the Datexel DAT 4035 compares

Other signal converters and isolators in our range. The highlighted row is this product. Tap any other name to open its page.

Datexel DAT 4035 compared with other signal converters and isolators
ProductTypeSignalsOutputs and communicationSupplyMounting
Acromag BusWorks XT1540 Ethernet I/O ModuleEthernet I/O4 discrete I/O8 analogue out; Modbus TCP, EtherNet/IP or PROFINET12 to 32 V DCDIN rail, 22.5 mm
Acromag 961EN and 962EN Analogue Input Ethernet I/OEthernet I/O6 differential current or voltage inputsModbus TCP or EtherNet/IP15 to 36 V DCDIN rail
Acromag 981EN, 982EN and 983EN Discrete Ethernet I/OEthernet I/O12 discrete inputs, outputs or bothModbus TCP or EtherNet/IP15 to 36 V DCDIN rail
Datexel DAT 511 Loop-Powered Current IsolatorLoop isolator0 to 20 mAIsolated 0 to 20 mALoop poweredDIN rail, 17 mm
Datexel DAT 4135 Isolated Universal Signal ConverterUniversal converterRTD, TC, mV, V, mA, resistanceIsolated current or voltage18 to 30 VdcDIN rail
Datexel DAT 4035 Loop-Powered Universal TransmitterUniversal transmitterRTD, TC, mV, V, mA, resistanceIsolated 4 to 20 mA loopLoop powered, 10 to 32 VdcDIN rail
Proplant PCE

From Selection to a Working Signal in Your Control System

A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.

01 / 04

Application review

We check the signals, channel count, network and mounting before recommending a device.

02 / 04

Supply

Instruments and modules from the brands on this page, with the brochure for your engineering file.

03 / 04

Configuration and installation

Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.

04 / 04

Integration

Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.

Before you order

What to tell us so we can recommend a device

Tick off what you already know. We will check the Datexel DAT 4035 against your application, or suggest a better fit from our range.

FAQ

Datexel DAT 4035 FAQ

What is the Datexel DAT 4035?

A two-wire isolated universal transmitter that converts RTD, thermocouple, resistance, potentiometer, mV, V and mA signals into a 4 to 20 mA loop.

Does it need a separate power supply?

No. It is powered by the 4 to 20 mA loop at 10 to 32 Vdc.

How much isolation does it give?

2000 Vac, 50 Hz for 1 minute between the input and the supply and output.

How is it programmed?

With the Datexel PROSOFT software through the PRODAT interface.

Which RTDs does it accept?

Pt100, Pt1000, Ni100 and Ni1000 in 2, 3 or 4-wire connection.

Can Proplant PCE help me choose the right automation device?

Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.

Datexel DAT 4035 universal transmitter

Let's Discuss Your Automation Project

Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.

Scroll to Top