Datexel DAT 4035 Two-Wire Isolated Universal Transmitter
A two-wire isolated universal transmitter that turns RTD, thermocouple, resistance, potentiometer, mV, V and mA signals into a 4 to 20 mA loop signal, programmed from a PC.

Key Features of the Datexel DAT 4035
Thermocouple and RTD
Thermocouples J, K, S, R, B, E, T and N; RTDs Pt100, Pt1000, Ni100 and Ni1000 in 2, 3 or 4 wires.
Linear signals
Resistance 0 to 300 Ω and 0 to 2000 Ω, potentiometer, mV -400 to +400 and -100 to +700, V -10 to +10 and mA -10 to +24.
4 to 20 mA loop output
A configurable 4 to 20 mA current loop output.
Isolation
2000 Vac, 50 Hz for 1 minute, input to supply and output.
PC programming
PROSOFT software through the PRODAT interface.
Accuracy
Linearity TC ±0.2 % and RTD ±0.1 % of full scale; thermal drift ±0.01 % per °C.
Datexel DAT 4035 Technical Specifications
Tap a group to filter the universal transmitter specifications, or show them all.

- 2000 VacIsolation1 min
- ±0.1 %RTD linearityof full scale
- 10 to 32 VdcLoop supply
- -20 to +70 °COperating temperature
| Specification | Details |
|---|---|
| Thermocouple inputs | J, K, S, R, B, E, T, N |
| RTD inputs | Pt100, Pt1000, Ni100, Ni1000 (2, 3 or 4 wires) |
| Other inputs | Resistance 0 to 300 Ω and 0 to 2000 Ω; potentiometer; mV -400 to +400 and -100 to +700; V -10 to +10; mA -10 to +24 |
| Accuracy | Linearity TC ±0.2 % f.s., RTD ±0.1 % f.s.; thermal drift ±0.01 % / °C |
| Output | 4 to 20 mA current loop, configurable; current output calibration ±7 µA |
| Configuration | PROSOFT through the PRODAT interface (PC) |
| Mounting | DIN rail, EN 50022 and EN 50035 |
| Weight | About 90 g; 12.5 mm thick |
| Power supply | 10 to 32 Vdc (loop); reverse polarity protection 60 Vdc max. |
| Isolation | 2000 Vac, 50 Hz, 1 min (input to supply and output) |
| Operating temperature | -20 to +70 °C |
| EMC and marking | CE; EN 61000-6-2, EN 61000-6-4 |
Figures from the Datexel DAT 4035 brochure. The brochure gives 2000 Vac isolation and PC configuration. Confirm the version for your application before ordering.
Download BrochureHow does the Datexel DAT 4035 work?
Tap a step, or let it run, to follow the signal from the field to the control system.
Step by step:
The DAT 4035 takes its power from the 4 to 20 mA loop, so it needs only the two loop wires. It suits panels where sensors of different types all have to arrive at the PLC as standard 4 to 20 mA signals.
Where the Datexel DAT 4035 is used
Typical uses for this universal transmitter, based on what it does.
- 01Temperature to 4 to 20 mARTDs and thermocouples converted on the DIN rail.
- 02Potentiometer positionPosition feedback converted to a loop signal.
- 03Isolated loopsIsolation between the sensor circuit and the loop.
How the Datexel DAT 4035 compares
Other signal converters and isolators in our range. The highlighted row is this product. Tap any other name to open its page.
| Product | Type | Signals | Outputs and communication | Supply | Mounting |
|---|---|---|---|---|---|
| Acromag BusWorks XT1540 Ethernet I/O Module | Ethernet I/O | 4 discrete I/O | 8 analogue out; Modbus TCP, EtherNet/IP or PROFINET | 12 to 32 V DC | DIN rail, 22.5 mm |
| Acromag 961EN and 962EN Analogue Input Ethernet I/O | Ethernet I/O | 6 differential current or voltage inputs | Modbus TCP or EtherNet/IP | 15 to 36 V DC | DIN rail |
| Acromag 981EN, 982EN and 983EN Discrete Ethernet I/O | Ethernet I/O | 12 discrete inputs, outputs or both | Modbus TCP or EtherNet/IP | 15 to 36 V DC | DIN rail |
| Datexel DAT 511 Loop-Powered Current Isolator | Loop isolator | 0 to 20 mA | Isolated 0 to 20 mA | Loop powered | DIN rail, 17 mm |
| Datexel DAT 4135 Isolated Universal Signal Converter | Universal converter | RTD, TC, mV, V, mA, resistance | Isolated current or voltage | 18 to 30 Vdc | DIN rail |
| Datexel DAT 4035 Loop-Powered Universal Transmitter | Universal transmitter | RTD, TC, mV, V, mA, resistance | Isolated 4 to 20 mA loop | Loop powered, 10 to 32 Vdc | DIN rail |
From Selection to a Working Signal in Your Control System
A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.
Application review
We check the signals, channel count, network and mounting before recommending a device.
Supply
Instruments and modules from the brands on this page, with the brochure for your engineering file.
Configuration and installation
Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.
Integration
Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.
What to tell us so we can recommend a device
Tick off what you already know. We will check the Datexel DAT 4035 against your application, or suggest a better fit from our range.
Other automation products to consider
Datexel DAT 4035 FAQ
What is the Datexel DAT 4035?
A two-wire isolated universal transmitter that converts RTD, thermocouple, resistance, potentiometer, mV, V and mA signals into a 4 to 20 mA loop.
Does it need a separate power supply?
No. It is powered by the 4 to 20 mA loop at 10 to 32 Vdc.
How much isolation does it give?
2000 Vac, 50 Hz for 1 minute between the input and the supply and output.
How is it programmed?
With the Datexel PROSOFT software through the PRODAT interface.
Which RTDs does it accept?
Pt100, Pt1000, Ni100 and Ni1000 in 2, 3 or 4-wire connection.
Can Proplant PCE help me choose the right automation device?
Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.
Let's Discuss Your Automation Project
Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.