Acromag 961EN and 962EN Analogue Input Ethernet I/O Modules
Stand-alone Ethernet I/O modules with 6 differential inputs, current on the 961EN and voltage on the 962EN, communicating by Modbus TCP/IP or EtherNet/IP and set up from a web browser.

Key Features of the Acromag 961EN / 962EN
Current inputs (961EN)
0 to 1 mA, 0 to 11 mA, 0 to 20 mA and 4 to 20 mA, 25 Ω input impedance; 0 to 20 A AC with an optional sensor.
Voltage inputs (962EN)
±78 mV to ±10 V DC in eight ranges, input impedance greater than 110.5 kΩ.
High accuracy
16-bit sigma-delta conversion, better than ±0.05 % of span on nominal ranges.
Modbus TCP or EtherNet/IP
-4006 models for Modbus TCP/IP, -6006 models for EtherNet/IP, 10/100 Mbps, conformance tested.
Web browser set-up
Configured from the module's built-in web page.
Isolation and approvals
1500 V AC three-way isolation; CE and UL/cUL Class I, Division 2, Groups A, B, C, D.
Acromag 961EN / 962EN Technical Specifications
Tap a group to filter the analogue to Ethernet module specifications, or show them all.

- 6Inputsdifferential
- ±0.05 %Accuracyof span
- 1500 V ACIsolation3-way
- -25 to 70 °COperating temperature
| Specification | Details |
|---|---|
| Current inputs (961EN) | 0 to 1 mA, 0 to 11 mA, 0 to 20 mA, 4 to 20 mA; 25 Ω impedance |
| AC current | 0 to 20 A AC with optional sensor |
| Voltage inputs (962EN) | ±78 mV to ±10 V DC (eight ranges); impedance greater than 110.5 kΩ |
| Conversion | 16-bit sigma-delta |
| Accuracy | Better than ±0.05 % of span for nominal input ranges |
| Protocols | Modbus TCP/IP (-4006) or EtherNet/IP (-6006), 10/100 Mbps |
| Configuration | Built-in web page through a standard web browser |
| Mounting | DIN EN 50022, 35 mm T rail |
| Power supply | 15 to 36 V DC, 2 W |
| Isolation | 1500 V AC for 60 seconds or 250 V AC continuous; 3-way (I/O, network, power) |
| Operating temperature | -25 to 70 °C |
| Approvals | CE; UL and cUL Class I, Division 2, Groups A, B, C, D; EtherNet/IP and Modbus TCP/IP conformance tested |
Figures from the Acromag 900EN analogue input brochure. Applications are the 900EN series list. Confirm the model and protocol for your application before ordering.
Download BrochureHow does the Acromag 961EN / 962EN work?
Tap a step, or let it run, to follow the signal from the field to the control system.
Step by step:
The 961EN or 962EN collects analogue signals in a remote panel and puts them on the plant network, so a distant tank or pump station needs only an Ethernet link back to the control room.
Where the Acromag 961EN / 962EN is used
Typical applications for this analogue to Ethernet module, from the manufacturer's documentation.
- 01Remote monitoringProcess variables at remote sites read over Ethernet.
- 02Tank, pump and valve controlLevel, pressure and position signals on the network.
- 03Environmental controlSignals for environmental control systems.
- 04Shutdown and alarmingInputs for process shutdown and alarm systems.
How the Acromag 961EN / 962EN compares
Other signal converters and isolators in our range. The highlighted row is this product. Tap any other name to open its page.
| Product | Type | Signals | Outputs and communication | Supply | Mounting |
|---|---|---|---|---|---|
| Acromag BusWorks XT1540 Ethernet I/O Module | Ethernet I/O | 4 discrete I/O | 8 analogue out; Modbus TCP, EtherNet/IP or PROFINET | 12 to 32 V DC | DIN rail, 22.5 mm |
| Acromag 961EN and 962EN Analogue Input Ethernet I/O | Ethernet I/O | 6 differential current or voltage inputs | Modbus TCP or EtherNet/IP | 15 to 36 V DC | DIN rail |
| Acromag 981EN, 982EN and 983EN Discrete Ethernet I/O | Ethernet I/O | 12 discrete inputs, outputs or both | Modbus TCP or EtherNet/IP | 15 to 36 V DC | DIN rail |
| Datexel DAT 511 Loop-Powered Current Isolator | Loop isolator | 0 to 20 mA | Isolated 0 to 20 mA | Loop powered | DIN rail, 17 mm |
| Datexel DAT 4135 Isolated Universal Signal Converter | Universal converter | RTD, TC, mV, V, mA, resistance | Isolated current or voltage | 18 to 30 Vdc | DIN rail |
| Datexel DAT 4035 Loop-Powered Universal Transmitter | Universal transmitter | RTD, TC, mV, V, mA, resistance | Isolated 4 to 20 mA loop | Loop powered, 10 to 32 Vdc | DIN rail |
From Selection to a Working Signal in Your Control System
A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.
Application review
We check the signals, channel count, network and mounting before recommending a device.
Supply
Instruments and modules from the brands on this page, with the brochure for your engineering file.
Configuration and installation
Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.
Integration
Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.
What to tell us so we can recommend a device
Tick off what you already know. We will check the Acromag 961EN / 962EN against your application, or suggest a better fit from our range.
Acromag 961EN / 962EN FAQ
What is the difference between the 961EN and the 962EN?
The 961EN has 6 differential DC current inputs and the 962EN has 6 differential DC voltage inputs.
Which protocols do they support?
Modbus TCP/IP on the -4006 models and EtherNet/IP on the -6006 models.
How accurate are they?
Better than ±0.05 % of span for the nominal input ranges.
Do they need configuration software?
No. They are configured from a built-in web page in a standard browser.
Can they measure AC current?
The 961EN can measure 0 to 20 A AC with an optional current sensor.
Can Proplant PCE help me choose the right automation device?
Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.
Let's Discuss Your Automation Project
Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.