Proplant PCE

Data logger and I/O

NOVUS FieldLogger High-Speed Data Logger with Ethernet and Modbus

A high-resolution, high-speed data logger with 8 universal analogue inputs, 8 configurable digital I/O, 2 relays, alarms and maths channels, connected over Modbus and Ethernet.

NOVUS8 universal inputsModbus TCP and RTU
NOVUS FieldLogger data logger
Product overview

What is the NOVUS FieldLogger?

FieldLogger is a data logger for analogue, digital and other variables, with high resolution and speed.

  • 018 universal inputsThermocouple, Pt100, Pt1000, mA, mV and V.
  • 02Up to 1000 / sReading and logging rate, 24-bit.
  • 03Modbus and EthernetRS485 Modbus RTU, Modbus TCP, FTP, SMTP.
Read more

Its 8 universal analogue inputs accept thermocouples, Pt100, Pt1000, mA, mV and V signals.

It adds 8 digital channels that can each be an input or an output, 2 relays, up to 32 alarms, a 24 Vdc supply for up to eight transmitters, and RS485, Ethernet and USB connections.

Key features

Key Features of the NOVUS FieldLogger

01 / 06

Universal analogue inputs

8 inputs for thermocouples J, K, T, E, N, R, S and B, Pt100, Pt1000, mA, mV and V.

02 / 06

High speed and resolution

Reading and logging up to 1000 per second with 24-bit A/D resolution.

03 / 06

Digital I/O and relays

8 digital channels, each configurable as input or output, plus 2 relays rated 3 A at 250 Vac or 30 Vdc.

04 / 06

Transmitter supply

A 24 Vdc output powers up to eight 4 to 20 mA transmitters.

05 / 06

Networking

RS485 as Modbus RTU master or slave; Ethernet 10/100 with HTTP, FTP client and server, SMTP, SNMP and Modbus TCP; USB device and USB host for a flash drive.

06 / 06

Alarms and HMI

Up to 32 configurable alarms, maths channels and an optional detachable operator interface.

Technical specifications

NOVUS FieldLogger Technical Specifications

Tap a group to filter the data logger specifications, or show them all.

NOVUS FieldLogger data logger, second view
NOVUS FieldLogger data logger.
  • 8Universal inputs
  • 1000 / sLogging rateup to
  • 24 bitResolution
  • 0.15 %Accuracyof span, Pt100 and linear
NOVUS FieldLogger technical specifications
SpecificationDetails
Analogue inputs8 universal: thermocouples J, K, T, E, N, R, S, B; Pt100; Pt1000; mA; mV; V
Reading and logging rateUp to 1000 per second
A/D resolution24 bit
AccuracyThermocouples J, K, T, E, N: 0.2 % of span ±1 °C; R, S, B: 0.2 % of span ±3 °C; Pt100, Pt1000, mA, mV, 0 to 5 V, 0 to 10 V: 0.15 % of span

Figures from the NOVUS FieldLogger brochure. The brochure gives more than one power rating, so confirm the supply and version for your application before ordering.

Download Brochure
How it works

How does the NOVUS FieldLogger work?

Tap a step, or let it run, to follow the signal from the field to the control system.

Step by step:

FieldLogger sits in the panel and can power the transmitters it reads. It logs every channel locally, acts on alarms through its relays, and shares the data over Modbus RTU, Modbus TCP, FTP or email.

SENSORS01FIELDLOGGER02ETHERNET03SCADA04
NOVUS FieldLogger: sensors, fieldlogger, ethernet, scada
Applications

Where the NOVUS FieldLogger is used

Typical uses for this data logger, based on what it does.

  • 01Process data loggingRecording temperatures, pressures and flows across a process at high speed.
  • 02Test and commissioningCapturing readings during plant trials and start-up.
  • 03Alarm and supervisionLocal alarms with relays, and data shared to SCADA.
Compare the range

How the NOVUS FieldLogger compares

Other data acquisition and iiot in our range. The highlighted row is this product. Tap any other name to open its page.

NOVUS FieldLogger compared with other data acquisition and iiot
ProductTypeSignalsOutputs and communicationSupplyMounting
NOVUS Cloud IIoT PlatformIIoT cloud platformData from NOVUS devicesDashboards, email and SMS alarmsHosted platformOnline
NOVUS FieldLogger Data LoggerData logger8 universal analogue, 8 digital I/ORS485 Modbus RTU, Ethernet, Modbus TCP, USB100 to 240 VacPanel
NOVUS LogBox Connect Wireless Data LoggerWireless data loggerUniversal analogue, 1 digitalBluetooth, Wi-Fi with Modbus TCP and MQTT, USB4 AA batteries or 10 to 30 VdcWall or field, IP40
Proplant PCE

From Selection to a Working Signal in Your Control System

A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.

01 / 04

Application review

We check the signals, channel count, network and mounting before recommending a device.

02 / 04

Supply

Instruments and modules from the brands on this page, with the brochure for your engineering file.

03 / 04

Configuration and installation

Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.

04 / 04

Integration

Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.

Before you order

What to tell us so we can recommend a device

Tick off what you already know. We will check the NOVUS FieldLogger against your application, or suggest a better fit from our range.

FAQ

NOVUS FieldLogger FAQ

What is the NOVUS FieldLogger?

A data logger with 8 universal analogue inputs, 8 digital I/O, 2 relays, alarms and Modbus and Ethernet connectivity.

Which signals can it read?

Thermocouples J, K, T, E, N, R, S and B, Pt100, Pt1000, mA, mV and voltage signals.

How fast does it log?

Up to 1000 readings per second, with 24-bit resolution.

Can it power my transmitters?

Yes. Its 24 Vdc output can power up to eight 4 to 20 mA transmitters.

How does it connect to SCADA?

Over RS485 Modbus RTU or Ethernet with Modbus TCP, and it can also send files by FTP and email by SMTP.

Can Proplant PCE help me choose the right automation device?

Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.

NOVUS FieldLogger data logger

Let's Discuss Your Automation Project

Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.

Scroll to Top