NOVUS FieldLogger High-Speed Data Logger with Ethernet and Modbus
A high-resolution, high-speed data logger with 8 universal analogue inputs, 8 configurable digital I/O, 2 relays, alarms and maths channels, connected over Modbus and Ethernet.

Key Features of the NOVUS FieldLogger
Universal analogue inputs
8 inputs for thermocouples J, K, T, E, N, R, S and B, Pt100, Pt1000, mA, mV and V.
High speed and resolution
Reading and logging up to 1000 per second with 24-bit A/D resolution.
Digital I/O and relays
8 digital channels, each configurable as input or output, plus 2 relays rated 3 A at 250 Vac or 30 Vdc.
Transmitter supply
A 24 Vdc output powers up to eight 4 to 20 mA transmitters.
Networking
RS485 as Modbus RTU master or slave; Ethernet 10/100 with HTTP, FTP client and server, SMTP, SNMP and Modbus TCP; USB device and USB host for a flash drive.
Alarms and HMI
Up to 32 configurable alarms, maths channels and an optional detachable operator interface.
NOVUS FieldLogger Technical Specifications
Tap a group to filter the data logger specifications, or show them all.

- 8Universal inputs
- 1000 / sLogging rateup to
- 24 bitResolution
- 0.15 %Accuracyof span, Pt100 and linear
| Specification | Details |
|---|---|
| Analogue inputs | 8 universal: thermocouples J, K, T, E, N, R, S, B; Pt100; Pt1000; mA; mV; V |
| Reading and logging rate | Up to 1000 per second |
| A/D resolution | 24 bit |
| Accuracy | Thermocouples J, K, T, E, N: 0.2 % of span ±1 °C; R, S, B: 0.2 % of span ±3 °C; Pt100, Pt1000, mA, mV, 0 to 5 V, 0 to 10 V: 0.15 % of span |
| Digital I/O | 8, each configured as input or output; outputs max. 30 Vdc and 200 mA |
| Relay outputs | 2 (NO, NC and common), 3 A at 250 Vac or 30 Vdc |
| Alarms | Up to 32 configurable alarms |
| Communication | RS485 Modbus RTU master or slave; Ethernet 10/100 Mbps with HTTP, FTP client and server, SMTP, SNMP, Modbus TCP; USB device; USB host (flash drive) |
| Operator interface | Detachable HMI (optional) |
| Configuration | Configurator software over USB, RS485 or Ethernet (Modbus TCP) |
| Transmitter supply | 24 Vdc output for up to eight 4 to 20 mA transmitters |
| Power supply | 100 to 240 Vac, 50/60 Hz (24 Vdc version listed in the brochure features) |
| Operating temperature | 0 to 50 °C |
| Protection | IP20 |
Figures from the NOVUS FieldLogger brochure. The brochure gives more than one power rating, so confirm the supply and version for your application before ordering.
Download BrochureHow does the NOVUS FieldLogger work?
Tap a step, or let it run, to follow the signal from the field to the control system.
Step by step:
FieldLogger sits in the panel and can power the transmitters it reads. It logs every channel locally, acts on alarms through its relays, and shares the data over Modbus RTU, Modbus TCP, FTP or email.
Where the NOVUS FieldLogger is used
Typical uses for this data logger, based on what it does.
- 01Process data loggingRecording temperatures, pressures and flows across a process at high speed.
- 02Test and commissioningCapturing readings during plant trials and start-up.
- 03Alarm and supervisionLocal alarms with relays, and data shared to SCADA.
How the NOVUS FieldLogger compares
Other data acquisition and iiot in our range. The highlighted row is this product. Tap any other name to open its page.
| Product | Type | Signals | Outputs and communication | Supply | Mounting |
|---|---|---|---|---|---|
| NOVUS Cloud IIoT Platform | IIoT cloud platform | Data from NOVUS devices | Dashboards, email and SMS alarms | Hosted platform | Online |
| NOVUS FieldLogger Data Logger | Data logger | 8 universal analogue, 8 digital I/O | RS485 Modbus RTU, Ethernet, Modbus TCP, USB | 100 to 240 Vac | Panel |
| NOVUS LogBox Connect Wireless Data Logger | Wireless data logger | Universal analogue, 1 digital | Bluetooth, Wi-Fi with Modbus TCP and MQTT, USB | 4 AA batteries or 10 to 30 Vdc | Wall or field, IP40 |
From Selection to a Working Signal in Your Control System
A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.
Application review
We check the signals, channel count, network and mounting before recommending a device.
Supply
Instruments and modules from the brands on this page, with the brochure for your engineering file.
Configuration and installation
Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.
Integration
Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.
What to tell us so we can recommend a device
Tick off what you already know. We will check the NOVUS FieldLogger against your application, or suggest a better fit from our range.
Other automation products to consider
NOVUS FieldLogger FAQ
What is the NOVUS FieldLogger?
A data logger with 8 universal analogue inputs, 8 digital I/O, 2 relays, alarms and Modbus and Ethernet connectivity.
Which signals can it read?
Thermocouples J, K, T, E, N, R, S and B, Pt100, Pt1000, mA, mV and voltage signals.
How fast does it log?
Up to 1000 readings per second, with 24-bit resolution.
Can it power my transmitters?
Yes. Its 24 Vdc output can power up to eight 4 to 20 mA transmitters.
How does it connect to SCADA?
Over RS485 Modbus RTU or Ethernet with Modbus TCP, and it can also send files by FTP and email by SMTP.
Can Proplant PCE help me choose the right automation device?
Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.
Let's Discuss Your Automation Project
Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.