Balluff Multiprotocol IO-Link Masters with 8 Ports
Field-mounted IO-Link masters with 8 ports that run PROFINET, EtherNet/IP, EtherCAT or Modbus TCP from one device, with REST API and MQTT for IIoT data.

Key Features of the Balluff IO-Link master
One device, four fieldbuses
PROFINET, EtherNet/IP, EtherCAT and Modbus TCP from the same master.
8 IO-Link ports
BNI00K7 and BNI00KJ have 4 Class A and 4 Class B ports.
BNI00K6 and BNI00L3 have 8 Class A ports.
IIoT interfaces
REST API and MQTT on all four versions, and OPC UA on BNI00K7 and BNI00KJ.
Digital I/O
Ports also work as PNP inputs and outputs: 12 of each on BNI00K7 and 16 of each on BNI00K6 and BNI00L3.
Safety Hub support
BNI00K7, BNI00KJ and BNI00L3 support the Balluff Safety Hub for PROFIsafe over IO-Link.
Harsh area versions
BNI00KJ and BNI00L3 are rated IP68 and IP69K, from -40 to 70 °C.
Balluff IO-Link master Technical Specifications
Tap a group to filter the IO-Link master specifications, or show them all.

- 8IO-Link portsper master
- 4Fieldbusesin one device
- 18 to 30VDCoperating voltage
- IP69KProtectionplastic versions
| Specification | Details |
|---|---|
| Fieldbus | PROFINET, EtherNet/IP, EtherCAT and Modbus TCP |
| IO-Link ports | 8. BNI00K7, BNI00KJ: 4 Class A and 4 Class B. BNI00K6, BNI00L3: 8 Class A |
| IO-Link version | 1.1.4 (BNI00K7, BNI00KJ, BNI00L3); 1.1.3 (BNI00K6) |
| IIoT interfaces | REST API and MQTT (all versions); OPC UA (BNI00K7, BNI00KJ) |
| Digital I/O | BNI00K7: 12 PNP inputs Type 3, 12 PNP outputs, max. 4 A per output. BNI00K6: 16 inputs, 16 outputs, max. 4 A. BNI00L3: 16 inputs, 16 outputs, max. 2 A |
| Current sum | 16 A sensor, 16 A actuator (BNI00K7, BNI00K6, BNI00L3) |
| Display | BNI00K7 and BNI00K6 |
| Safety Hub support | BNI00K7, BNI00KJ and BNI00L3 |
| Connectors | Fieldbus 2x M12 D-coded female; power in and out M12 L-coded; ports 8x M12 A-coded female, 5-pin |
| Housing | BNI00K7, BNI00K6: die-cast zinc, 68 x 32 x 224 mm. BNI00KJ, BNI00L3: plastic with stainless steel inserts, 68 x 38.3 x 226.2 mm |
| Operating voltage | 18 to 30 VDC |
| Protection | IP67 (BNI00K7, BNI00K6); IP68 and IP69K (BNI00KJ, BNI00L3) |
| Ambient temperature | -5 to 70 °C (BNI00K7, BNI00K6); -40 to 70 °C (BNI00KJ, BNI00L3) |
Figures from the Balluff product page for each model, read in November 2026. The Balluff data sheet for each model is linked below. Confirm the version for your fieldbus and environment before ordering.
- Balluff BNI00K7 data sheet (PDF)
- Balluff BNI00KJ data sheet (PDF)
- Balluff BNI00K6 data sheet (PDF)
- Balluff BNI00L3 data sheet (PDF)
How does the Balluff IO-Link master work?
Tap a step, or let it run, to follow the signal from the field to the control system.
Step by step:
Each port talks point to point to one IO-Link device over a standard unshielded M12 cable, carrying process values, parameters and diagnostics. The master maps that data onto PROFINET, EtherNet/IP, EtherCAT or Modbus TCP for the PLC, and can publish it through REST API or MQTT at the same time.
Where the Balluff IO-Link master is used
Typical uses for this IO-Link master, based on what it does.
- 01Machine I/OBringing sensors and actuators on a machine onto one fieldbus connection.
- 02Washdown areasIP68 and IP69K versions for food, beverage and other wet areas.
- 03IIoT dataSharing sensor data with plant systems through REST API or MQTT.
How the Balluff IO-Link master compares
Other io-link and balluff in our range. The highlighted row is this product. Tap any other name to open its page.
| Product | Type | Signals | Outputs and communication | Supply | Mounting |
|---|---|---|---|---|---|
| Balluff Multiprotocol IO-Link Masters | IO-Link master | 8 IO-Link ports | PROFINET, EtherNet/IP, EtherCAT, Modbus TCP | 18 to 30 VDC | Machine, IP67 to IP69K |
| Balluff IO-Link Sensor and Actuator Hubs | IO-Link hub | 16 DI and 16 DO, or 8 analogue in | IO-Link to one master port | 18 to 30.2 VDC | Machine, IP67 |
| Balluff IO-Link Sensors | IO-Link sensors | Inductive, optical, capacitive, magnetic, distance, pressure | IO-Link 1.1 plus switching or analogue | 10 to 30 VDC, model dependent | Machine and process |
| Balluff Condition Monitoring Sensors | Condition monitoring sensor | 3-axis vibration, contact temperature | IO-Link | 24 V DC | Machine mount, IP67 to IP69K |
| autosen AS005 IO-Link Flow Sensor | Thermal flow sensor | Flow and temperature, liquids and gases | 2 switching, 4 to 20 mA, IO-Link | 18 to 30 V DC | M18 x 1.5 adapter, IP65 and IP67 |
| Balluff IO-Link Safety Hub | Safety I/O hub | 12 safe inputs, 2 safe outputs | PROFIsafe over IO-Link | 19.2 to 30 V | Machine, IP67 |
| Balluff Heartbeat Power Supplies with IO-Link | 24 V power supply | 192 to 360 W | IO-Link diagnostics | 85 to 264 V AC in, model dependent | DIN rail IP20 or field IP67 |
| Balluff M12 Cordsets and Splitters | M12 cordsets | Single, double-ended, Y-splitter, NAMUR | Sensor and power cable | 250 VDC / 250 VAC, 4 A | IP67 to IP69K |
From Selection to a Working Signal in Your Control System
A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.
Application review
We check the signals, channel count, network and mounting before recommending a device.
Supply
Instruments and modules from the brands on this page, with the brochure for your engineering file.
Configuration and installation
Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.
Integration
Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.
What to tell us so we can recommend a device
Tick off what you already know. We will check the Balluff IO-Link master against your application, or suggest a better fit from our range.
Balluff IO-Link master FAQ
What does an IO-Link master do?
It connects IO-Link sensors and actuators to the fieldbus, passing their process values, parameters and diagnostics to the PLC.
Which fieldbuses do these masters support?
PROFINET, EtherNet/IP, EtherCAT and Modbus TCP, all from the same device.
How many devices can one master take?
Eight, one on each M12 IO-Link port.
Which version suits washdown areas?
BNI00KJ or BNI00L3. Both have a plastic housing rated IP68 and IP69K and run from -40 to 70 °C.
Can the data go to IIoT systems as well as the PLC?
Yes. All four versions offer REST API and MQTT, and BNI00K7 and BNI00KJ add OPC UA.
Can Proplant PCE help me choose the right automation device?
Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.
Let's Discuss Your Automation Project
Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.