Proplant PCE

IO-Link flow switches

autosen AS005 Thermal Flow Sensor with IO-Link and Temperature Output

A thermal flow sensor that measures flow and temperature at the same time, with two outputs, a colour display and IO-Link for water, glycol, oils and air.

autosenFlow and temperatureIO-Link
autosen AS005 thermal flow sensor
Product overview

What is the autosen AS005?

The AS005 is a programmable thermal flow sensor that fits a process adapter with its M18 x 1.5 internal thread.

  • 01Flow and temperatureTwo values from one sensor.
  • 02Liquids and gases0.04 to 3 m/s liquids, 2 to 100 m/s gases.
  • 03IO-LinkParameters and values over the M12 cable.
Read more

It measures flow and temperature at the same time and reports them through two separate outputs.

It monitors water, glycol solutions, air and oils, with sensitivity curves programmed for the medium. A red and green display shows at a glance whether the process is in its target range, and IO-Link carries the values and settings to the control system.

Key features

Key Features of the autosen AS005

01 / 06

Two measurements

Flow and temperature at the same time, on two separate outputs.

02 / 06

Programmable for the medium

Sensitivity curves for water, glycol solutions, air, and low and high viscosity oils.

03 / 06

Colour display

4-digit display that shows the process value in red or green, so you see at once whether it is in range.

The upper housing rotates by 345°.

04 / 06

Flexible outputs

Two programmable NO/NC switching outputs, PNP or NPN, and a scalable 4 to 20 mA output, with short-circuit, overload and reverse polarity protection.

05 / 06

IO-Link

Set up through the buttons or by IO-Link parameterisation.

06 / 06

Robust

Pressure resistant to 100 bar, IP65 and IP67, ambient -40 to 80 °C, MTTF 212 years.

Technical specifications

autosen AS005 Technical Specifications

Tap a group to filter the IO-Link flow sensor specifications, or show them all.

autosen AS005 flow sensor with colour display and M12 connector
autosen AS005, image from the AS005 data sheet.
  • 0.04 to 3m/sliquids
  • 2 to 100m/sgases
  • -20 to 90°Cmedium temperature
  • 100 barPressure rating
autosen AS005 technical specifications
SpecificationDetails
MediaWater; glycol solutions; air; low viscosity oils (40 mm²/s or less at 40 °C); high viscosity oils (over 40 mm²/s at 40 °C)
Flow measurement speedLiquids 0.04 to 3 m/s; gases 2 to 100 m/s
Adjustment range0 to 6 m/s (liquid); 0 to 200 m/s (gaseous)
Temperature measuring range-20 to 90 °C
AccuracyFlow ±(7 % of measured value + 2 % of range end value); temperature ±0.3 °C / ±1 °C
Resolution and reproducibilityResolution 0.02 m/s (water) and 0.2 °C; reproducibility 0.05 m/s (water)
Response time, flowWater 0.5 s; glycol 0.8 s; air 7 s; oil 1.8 s (T09)
Response time, temperature1.5 s (water)

Figures from the AS005 data sheet. Resolution, reproducibility and temperature response apply to water. With the analogue output, use only sensor cables without LED, as the data sheet advises. autosen product page

Download Data Sheet
How it works

How does the autosen AS005 work?

Tap a step, or let it run, to follow the signal from the field to the control system.

Step by step:

A thermal flow sensor heats its tip slightly and measures how quickly the passing medium carries that heat away: the faster the flow, the more heat is removed. The same sensor reads the medium temperature, so one device reports both. There are no moving parts in the flow.

PIPE FLOW01AS005 SENSOR02IO-LINK MASTER03PLC04
autosen AS005: pipe flow, as005 sensor, io-link master, plc
Applications

Where the autosen AS005 is used

Typical uses for this IO-Link flow sensor, based on what it does.

  • 01Cooling waterChecking that cooling water is flowing to a machine or heat exchanger.
  • 02Lubrication oilMonitoring oil flow in lubrication circuits.
  • 03Compressed air and gasesFlow monitoring in air and gas lines.
Compare the range

How the autosen AS005 compares

Other io-link and balluff in our range. The highlighted row is this product. Tap any other name to open its page.

autosen AS005 compared with other io-link and balluff
ProductTypeSignalsOutputs and communicationSupplyMounting
Balluff Multiprotocol IO-Link MastersIO-Link master8 IO-Link portsPROFINET, EtherNet/IP, EtherCAT, Modbus TCP18 to 30 VDCMachine, IP67 to IP69K
Balluff IO-Link Sensor and Actuator HubsIO-Link hub16 DI and 16 DO, or 8 analogue inIO-Link to one master port18 to 30.2 VDCMachine, IP67
Balluff IO-Link SensorsIO-Link sensorsInductive, optical, capacitive, magnetic, distance, pressureIO-Link 1.1 plus switching or analogue10 to 30 VDC, model dependentMachine and process
Balluff Condition Monitoring SensorsCondition monitoring sensor3-axis vibration, contact temperatureIO-Link24 V DCMachine mount, IP67 to IP69K
autosen AS005 IO-Link Flow SensorThermal flow sensorFlow and temperature, liquids and gases2 switching, 4 to 20 mA, IO-Link18 to 30 V DCM18 x 1.5 adapter, IP65 and IP67
Balluff IO-Link Safety HubSafety I/O hub12 safe inputs, 2 safe outputsPROFIsafe over IO-Link19.2 to 30 VMachine, IP67
Balluff Heartbeat Power Supplies with IO-Link24 V power supply192 to 360 WIO-Link diagnostics85 to 264 V AC in, model dependentDIN rail IP20 or field IP67
Balluff M12 Cordsets and SplittersM12 cordsetsSingle, double-ended, Y-splitter, NAMURSensor and power cable250 VDC / 250 VAC, 4 AIP67 to IP69K
Proplant PCE

From Selection to a Working Signal in Your Control System

A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.

01 / 04

Application review

We check the signals, channel count, network and mounting before recommending a device.

02 / 04

Supply

Instruments and modules from the brands on this page, with the brochure for your engineering file.

03 / 04

Configuration and installation

Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.

04 / 04

Integration

Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.

Before you order

What to tell us so we can recommend a device

Tick off what you already know. We will check the autosen AS005 against your application, or suggest a better fit from our range.

FAQ

autosen AS005 FAQ

What does the autosen AS005 measure?

Flow and temperature at the same time, on two separate outputs.

Which media can it monitor?

Water, glycol solutions, air, and low and high viscosity oils, with a sensitivity curve programmed for each.

What flow speeds does it measure?

0.04 to 3 m/s in liquids and 2 to 100 m/s in gases.

Does it need IO-Link?

No. It works with its switching and 4 to 20 mA outputs, and IO-Link adds remote set-up and data. To use IO-Link, connect it to a master such as the Balluff multiprotocol IO-Link master.

How is it mounted?

On a process adapter through its M18 x 1.5 internal thread. It is pressure resistant to 100 bar.

Can Proplant PCE help me choose the right automation device?

Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.

autosen AS005 IO-Link flow sensor

Let's Discuss Your Automation Project

Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.

Scroll to Top