Proplant PCE

Temperature switch and transmitter

ACS Thermocont TS4S Electronic Temperature Switch with LED Display

An all-in-one electronic temperature switch with a bright LED display, two PNP switch outputs and an optional 4 to 20 mA signal, for monitoring, control and continuous measurement in gases, vapours, liquids and dusts.

ACS-Control-SystemPt100 class ALED display
ACS Thermocont TS4S temperature switch with LED display
Product overview

What is the Thermocont TS4S?

The ACS Thermocont TS4S is an electronic temperature switch for monitoring, controlling and continuously measuring temperatures in gases, vapours, liquids and dusts.

  • 01All in oneSensor, electronics, LED display and keys in one stainless unit.
  • 02Switch and signalUp to two PNP switch outputs plus a 4 to 20 mA signal.
  • 03Up to +500 °CMeasuring range -99.9 to +500 °C on the type S version.
Read more

A long-term stable Pt100 class A sensor sits in a stainless sensor tube, and the electronics, display and keys sit in the head above it.

Depending on the output code, the TS4S gives two PNP switch outputs, one switch output with a 4 to 20 mA signal, or both switches with the 4 to 20 mA signal, all through an M12 plug. A self-supervising version with two sensors reports drift as soon as it passes a set limit.

Key features

Key Features of the Thermocont TS4S

01 / 06

Pt100 class A sensor

A long-term stable Pt100 class A resistance sensor to DIN EN 60751 measures the process temperature.

02 / 06

Self-supervision and drift alarm

The type D version adds a semiconductor sensor alongside the Pt100.

The two are monitored against each other, and drift is reported as soon as it passes the set limit, without waiting for a scheduled calibration.

03 / 06

LED display and keys

A high-brightness digital LED display, function LEDs and a 3-key keyboard with tactile feedback.

The enclosure and display can be rotated.

04 / 06

Switch and analogue outputs

PNP switch outputs up to 200 mA, current limited and short-circuit protected, and a 4 to 20 mA output, through an M12x1 plug.

05 / 06

Front-flush sealing

Dead-space-free front-flush O-ring process connections in FPM (Viton) or FDA-listed EPDM suit viscous or contaminated media.

06 / 06

Hygienic and robust

Wetted parts in stainless steel 1.4404/316L or 1.4571/316Ti with Ra < 0.8 µm.

CIP and SIP capable, with a captive laser-marked type label.

Technical specifications

Thermocont TS4S Technical Specifications

Tap a group to filter the temperature switch specifications, or show them all.

ACS Thermocont TS4S temperature switch with LED display
ACS Thermocont TS4S Temperature Switch.
  • -99.9 to +500 °CMeasuring rangetype S, range code 3
  • ≤ 100 barProcess pressuredepends on type
  • 2x PNP + 4 to 20 mAOutputsdepends on output code
  • IP65 / IP67ProtectionEN/IEC 60529
Thermocont TS4S technical specifications
SpecificationDetails
Measuring systemS: Pt100 class A resistance sensor; D: Pt100 class A plus semiconductor sensor with self-supervision
Measuring ranges-50 to +200 °C (type S); -99.9 to +500 °C (type S); -50 to +175 °C (type D)
Characteristic deviation, display and switch≤ ±0.6 % FS
Characteristic deviation, current output≤ ±0.9 K at ±100 °C
Self-supervision (type D)Display and switch ≤ ±0.2 K; current output ≤ ±0.4 K; drift monitoring ≤ ±0.2 K
Long-term drift≤ ±0.1 % FS per year
Temperature deviationDisplay and switch ≤ ±0.003 % FS/K; current output ≤ ±0.008 % FS/K

Figures from the ACS-Control-System brochure. Confirm the version and options for your application before ordering.

Download Brochure
How it works

How does the Thermocont TS4S work?

Tap a step, or let it run, to follow the signal from the process to the control system.

Step by step:

The TS4S switches a pump, heater or alarm directly when the temperature crosses a set point, and can send the measured value to the control system at the same time. On the self-supervising version, the second sensor checks the Pt100 continuously.

SW1 ON4 to 20 mAPLC / SCADAPROCESS PIPESPSET POINT86.4LED DISPLAY
Thermocont TS4S: sensor, set point, display and switch outputs
Applications

Where the Thermocont TS4S is used

Typical applications for this temperature switch, from the manufacturer's documentation.

  • 01Machinery and plant engineeringTemperature monitoring and switching on machines and plant equipment.
  • 02Hydraulic and pneumatic systemsOil and system temperature switching on hydraulic power units.
  • 03Air-conditioning and refrigerationTemperature control points in cooling and air-handling systems.
  • 04Process industryMonitoring and control of process temperatures in gases, vapours, liquids and dusts.
  • 05Environmental technologyTemperature measurement on environmental and treatment plant.
  • 06Paint and coating industryFront-flush versions for viscous and contaminated media.
Compare the range

How the Thermocont TS4S compares

The highlighted row is this instrument. Tap any other name to open its page.

Thermocont TS4S compared with the temperature measurement range
InstrumentTypeInputOutputSupplyMounting
ACS Thermocont TS4S Temperature SwitchTemperature switchPt100 class A, built in2x PNP switch, 4 to 20 mA option10.5 to 35 VDCG½" or G¼" thread, compression fitting
Datexel DAT 1066 Head-Mount Temperature TransmitterHead-mount transmitter, isolatedRTD, thermocouple, mV, resistance4 to 20 mA7 to 32 VdcDIN B head, DIN rail kit
NOVUS TxBlock-USB and TxRail-USB Temperature TransmittersHead-mount or DIN rail transmitterThermocouple, Pt100, Pt1000, NTC, mV4 to 20 mA; 0 to 10 V on TxRail-USB8 to 35 Vdc (TxBlock-USB)Sensor head or DIN rail
NOVUS TxIsoPack-USB Isolated Temperature TransmitterHead-mount transmitter, isolatedPt100, thermocouple, mV4 to 20 mA or 20 to 4 mA12 to 35 VdcSensor head
NOVUS TxMini Compact Temperature TransmitterCompact transmitterPt100 or Pt1000, 3-wire4 to 20 mA8 to 35 VdcM12 or DIN 43650 connector
NOVUS RHT-Air Wireless Temperature and Humidity TransmitterWireless transmitterBuilt-in temperature and humidity sensorsWireless to AirGate-ModbusBattery or 10 to 35 VdcWall mount or probe extension
Proplant PCE

From Selection to a Working Signal in Your Control System

A temperature reading is only as useful as the signal that reaches the control room. Proplant PCE handles the steps around the instrument as well as the instrument itself.

01 / 04

Application review

We check the process temperature, sensor type, mounting and the signal your control system needs before recommending a transmitter.

02 / 04

Supply

Transmitters, switches and sensors from the brands on this page, with the brochure for your engineering file.

03 / 04

Configuration and installation

Range, sensor type and failure behaviour set before delivery, then mounting, cabling and termination by our E&I team.

04 / 04

Integration

Loop wiring and scaling in your PLC or SCADA, so the temperature on screen matches the process.

Before you order

What to tell us so we can recommend an instrument

Tick off what you already know. We will check the Thermocont TS4S against your conditions, or suggest a better fit from our range.

FAQ

Thermocont TS4S FAQ

What is the Thermocont TS4S?

An electronic temperature switch from ACS-Control-System with a Pt100 class A sensor, an LED display, PNP switch outputs and an optional 4 to 20 mA signal.

What temperature range does the TS4S cover?

The type S version is available for -50 to +200 °C or -99.9 to +500 °C. The self-supervising type D covers -50 to +175 °C.

What outputs are available?

Two PNP switch outputs, one switch output with 4 to 20 mA, two switch outputs with 4 to 20 mA, or a Desina-conformal version with one switch and 4 to 20 mA.

What does self-supervision mean on the TS4S?

On the type D version a semiconductor sensor works alongside the Pt100. The two readings are monitored against each other, and the unit signals when drift passes the set limit.

Can the TS4S be used in hygienic applications?

The wetted parts are stainless steel with Ra < 0.8 µm, front-flush O-ring connections are available in FDA-listed EPDM, and the unit is CIP and SIP capable.

Can Proplant PCE help me choose the right temperature transmitter?

Yes. Send us the sensor type, temperature range, mounting and the output your control system needs, and our team will recommend a suitable instrument.

Thermocont TS4S temperature switch

Let's Discuss Your Temperature Application

Tell us what you are measuring, where the sensor sits and what the signal needs to do. We will come back with a recommendation and the brochure.

Scroll to Top