Proplant PCE

Isolated universal transmitter

Datexel DAT 1066 Isolated Head-Mount Temperature Transmitter

An isolated two-wire universal transmitter that fits in a DIN B sensor head and turns RTD, thermocouple, mV, resistance or potentiometer signals into a 4 to 20 mA loop signal, configured from a PC.

DatexelRTD and thermocouple1500 Vac isolation
Datexel DAT 1066 head-mount temperature transmitter
Product overview

What is the Datexel DAT 1066?

The Datexel DAT 1066 is an isolated two-wire universal transmitter programmable by PC.

  • 01Universal inputRTD, thermocouple, mV, resistance and potentiometer.
  • 021500 Vac isolationInput isolated from the supply and output.
  • 03Configured by PCPROSOFT software, with or without the loop connected.
Read more

It linearises RTD and standard thermocouple signals, with internal cold junction compensation, and converts linear resistance and voltage signals into a 4 to 20 mA current loop.

The input is isolated from the loop at 1500 Vac, which removes the effect of ground loops in heavy industrial conditions. It mounts in a DIN B sensor head, or on a DIN rail with the optional kit, and can be reconfigured in the field.

Key features

Key Features of the Datexel DAT 1066

01 / 06

Universal input

Thermocouples J, K, S, R, B, E, T and N; Pt100, Pt1000, Ni100 and Ni1000 RTDs in 2, 3 or 4 wires; mV; resistance; and potentiometers.

02 / 06

Galvanic isolation

1500 Vac, 50 Hz for 1 minute between the input and the supply and output, removing the effects of ground loops.

03 / 06

PC configuration

Configured with PROSOFT on Windows with the loop connected, or through the PRODAT05 or PRODAT06 interface without the power loop.

04 / 06

Custom linearisation

Standard linearisation, none, or a custom per-step curve for non-standard sensors.

05 / 06

Burn-out alarm

Burn-out high or low on sensor failure, direct 4-20 mA or reverse 20-4 mA action, and a damping filter of 0.3 to 30 s.

06 / 06

Head or rail mounting

DIN B in-head mounting, or DIN rail (EN 50022) with the optional stirrup kit.

43 mm diameter, 24 mm high, about 50 g.

Technical specifications

Datexel DAT 1066 Technical Specifications

Tap a group to filter the head mount temperature transmitter specifications, or show them all.

Datexel DAT 1066 head-mount temperature transmitter
Datexel DAT 1066 Head-Mount Temperature Transmitter.
  • 1500 VacIsolationinput to supply and output
  • ±0.1 % f.s.RTD linearityTC ±0.2 % f.s.
  • 7 to 32 VdcLoop supply
  • -40 to +85 °COperating temperature
Datexel DAT 1066 technical specifications
SpecificationDetails
Thermocouple inputsJ -200 to 1200 °C; K -200 to 1370 °C; S and R -50 to 1760 °C; B 400 to 1820 °C; E -200 to 1000 °C; T -200 to 400 °C; N -200 to 1300 °C
RTD inputs (2, 3 or 4 wires)Pt100 -200 to 850 °C; Pt1000 -200 to 200 °C; Ni100 -60 to 180 °C; Ni1000 -60 to 150 °C; min. span 50 °C
Voltage input-100 to +700 mV, min. span 2 mV
Resistance and potentiometerResistance 0 to 300 Ω or 0 to 2000 Ω; potentiometer 0 to 200 Ω, 200 to 500 Ω, 0.5 to 50 kΩ
Input calibrationRTD: greater of ±0.1 % f.s. or ±0.2 °C; mV and TC: greater of ±0.1 % f.s. or ±10 µV
LinearityTC ±0.2 % f.s.; RTD ±0.1 % f.s.
Cold junction compensation±0.5 °C, internal or external
Thermal driftFull scale ±0.01 %/°C; CJC ±0.01 %/°C
Response time (10 to 90 %)About 400 ms

Figures from the Datexel brochure. Confirm the version and options for your application before ordering.

Download Brochure
How it works

How does the Datexel DAT 1066 work?

Tap a step, or let it run, to follow the signal from the process to the control system.

Step by step:

Because it powers itself from the 4 to 20 mA loop, the DAT 1066 needs only two wires back to the control system. The isolated input stops ground loops between the sensor and the PLC from upsetting the reading.

12.0 mA75.0 °CPLC / SCADAPROCESS PIPELINEARISEISOLATION
Datexel DAT 1066: sensor, transmitter in the head, 4 to 20 mA loop
Applications

Where the Datexel DAT 1066 is used

Typical applications for this head mount temperature transmitter, from the manufacturer's documentation.

  • 01RTD temperature measurementPt100, Pt1000, Ni100 and Ni1000 sensors in 2, 3 or 4 wires.
  • 02Thermocouple temperature measurementEight thermocouple types up to 1820 °C, with cold junction compensation.
  • 03Resistance and potentiometer signalsLinear resistance, potentiometer and mV signals converted to 4 to 20 mA.
  • 04Heavy industrial conditionsIsolated input where ground loops would otherwise affect the reading.
Compare the range

How the Datexel DAT 1066 compares

The highlighted row is this instrument. Tap any other name to open its page.

Datexel DAT 1066 compared with the temperature measurement range
InstrumentTypeInputOutputSupplyMounting
ACS Thermocont TS4S Temperature SwitchTemperature switchPt100 class A, built in2x PNP switch, 4 to 20 mA option10.5 to 35 VDCG½" or G¼" thread, compression fitting
Datexel DAT 1066 Head-Mount Temperature TransmitterHead-mount transmitter, isolatedRTD, thermocouple, mV, resistance4 to 20 mA7 to 32 VdcDIN B head, DIN rail kit
NOVUS TxBlock-USB and TxRail-USB Temperature TransmittersHead-mount or DIN rail transmitterThermocouple, Pt100, Pt1000, NTC, mV4 to 20 mA; 0 to 10 V on TxRail-USB8 to 35 Vdc (TxBlock-USB)Sensor head or DIN rail
NOVUS TxIsoPack-USB Isolated Temperature TransmitterHead-mount transmitter, isolatedPt100, thermocouple, mV4 to 20 mA or 20 to 4 mA12 to 35 VdcSensor head
NOVUS TxMini Compact Temperature TransmitterCompact transmitterPt100 or Pt1000, 3-wire4 to 20 mA8 to 35 VdcM12 or DIN 43650 connector
NOVUS RHT-Air Wireless Temperature and Humidity TransmitterWireless transmitterBuilt-in temperature and humidity sensorsWireless to AirGate-ModbusBattery or 10 to 35 VdcWall mount or probe extension
Proplant PCE

From Selection to a Working Signal in Your Control System

A temperature reading is only as useful as the signal that reaches the control room. Proplant PCE handles the steps around the instrument as well as the instrument itself.

01 / 04

Application review

We check the process temperature, sensor type, mounting and the signal your control system needs before recommending a transmitter.

02 / 04

Supply

Transmitters, switches and sensors from the brands on this page, with the brochure for your engineering file.

03 / 04

Configuration and installation

Range, sensor type and failure behaviour set before delivery, then mounting, cabling and termination by our E&I team.

04 / 04

Integration

Loop wiring and scaling in your PLC or SCADA, so the temperature on screen matches the process.

Before you order

What to tell us so we can recommend an instrument

Tick off what you already know. We will check the Datexel DAT 1066 against your conditions, or suggest a better fit from our range.

FAQ

Datexel DAT 1066 FAQ

What is the Datexel DAT 1066?

An isolated two-wire universal transmitter, programmable by PC, that mounts in a DIN B sensor head and gives a 4 to 20 mA output.

Which sensors can be connected?

Thermocouples J, K, S, R, B, E, T and N, Pt100, Pt1000, Ni100 and Ni1000 RTDs in 2, 3 or 4 wires, mV signals, resistance and potentiometers.

Why does isolation matter?

The 1500 Vac isolation between input and loop removes the effect of ground loops, which can otherwise shift or upset the reading in heavy industrial conditions.

How is the DAT 1066 configured?

With the PROSOFT software on a Windows PC, either with the loop connected or through the PRODAT05 or PRODAT06 interface without the power loop.

Can it be mounted on a DIN rail?

Yes. It is made for DIN B in-head mounting, and an optional kit mounts it on an EN 50022 DIN rail.

Can Proplant PCE help me choose the right temperature transmitter?

Yes. Send us the sensor type, temperature range, mounting and the output your control system needs, and our team will recommend a suitable instrument.

Datexel DAT 1066 head mount temperature transmitter

Let's Discuss Your Temperature Application

Tell us what you are measuring, where the sensor sits and what the signal needs to do. We will come back with a recommendation and the brochure.

Scroll to Top