Proplant PCE

Isolated, loop powered

NOVUS TxIsoPack-USB Isolated Head-Mount Temperature Transmitter

A fully isolated, two-wire, loop-powered temperature transmitter for the sensor head. The 4 to 20 mA output is linearised and isolated, and the sensor type and range are set straight from a PC USB port.

NOVUSIsolatedUSB configuration
NOVUS TxIsoPack-USB isolated temperature transmitter
Product overview

What is the TxIsoPack-USB?

The NOVUS TxIsoPack-USB is a fully isolated, two-wire, loop-powered temperature transmitter with a 4 to 20 mA output, made to mount inside a sensor head.

  • 011000 Vac isolationInput isolated from output for 1 minute at 1000 Vac.
  • 02Pt100, TC and mVPt100 in 2, 3 or 4 wires, nine thermocouple types, 0 to 50 mV.
  • 03USB set-upSensor type and range set from a PC USB port.
Read more

The output is linearised and follows the selected temperature sensor type.

Sensor type and range are set by connecting the transmitter directly to a PC USB port, with no extra interface, converter or driver. Units can be supplied pre-configured, or set up on site with a standard USB cable and the NOVUS TxConfig software.

Key features

Key Features of the TxIsoPack-USB

01 / 06

Fully isolated

1000 Vac for 1 minute between input and output, on a loop-powered two-wire 4 to 20 mA transmitter.

02 / 06

Pt100, thermocouple and mV

Pt100 in 2, 3 or 4 wires, thermocouples J, K, T, E, N, R, S and B, and 0 to 50 mV.

03 / 06

Direct or reverse output

4 to 20 mA or 20 to 4 mA, linear with the measured temperature, with 12-bit (0.004 mA) resolution.

04 / 06

USB configuration

Sensor type and range set by connecting to a PC USB port, with no extra interface or driver.

05 / 06

Head-mount housing

ABS housing, 44 mm diameter and 24 mm maximum height, for mounting inside the sensor head.

06 / 06

Reverse polarity protection

Internal protection against reversed supply polarity, with internal cold junction compensation for thermocouples.

Technical specifications

TxIsoPack-USB Technical Specifications

Tap a group to filter the isolated temperature transmitter specifications, or show them all.

NOVUS TxIsoPack-USB isolated temperature transmitter
NOVUS TxIsoPack-USB Isolated Temperature Transmitter.
  • 1000 VacIsolationinput to output, 1 min
  • 0.2 %Accuracyof max. range, Pt100 and mV
  • 12 to 35 VdcSupply
  • ≤ 500 msResponse time
TxIsoPack-USB technical specifications
SpecificationDetails
Pt100 input2, 3 or 4 wires; -200 to 650 °C; min. span 40 °C; 0.17 mA excitation; α = 0.00385 to IEC 60751
Thermocouple inputsJ -100 to 760 °C; K -150 to 1370 °C; T -160 to 400 °C; E -90 to 720 °C; N -270 to 1300 °C; R and S -50 to 1760 °C; B 500 to 1820 °C
Voltage input0 to 50 mV, min. span 5 mV; impedance > 1 MΩ
Total accuracy0.3 % of max. range for thermocouples; 0.2 % of max. range for Pt100 and voltage
Cold junction compensationInternal, for thermocouples
Response time≤ 500 ms

Figures from the NOVUS TxIsoPack-USB product page and the TxIsoPack operating manual. Accuracy is a percentage of the sensor's maximum range, not the range you set. Confirm the version and options for your application before ordering.

NOVUS product page
How it works

How does the TxIsoPack-USB work?

Tap a step, or let it run, to follow the signal from the process to the control system.

Step by step:

The TxIsoPack-USB takes its power from the 4 to 20 mA loop, so only two wires run back to the control system. Isolation keeps a grounded thermocouple or a noisy plant earth from disturbing the loop.

12.0 mA75.0 °CPLC / SCADAPROCESS PIPELINEARISEISOLATION
TxIsoPack-USB: sensor, transmitter in the head, 4 to 20 mA loop
Applications

Where the TxIsoPack-USB is used

Typical applications for this isolated temperature transmitter, from the manufacturer's documentation.

  • 01Head-mounted temperature assembliesMounts inside the connection head of an RTD or thermocouple assembly.
  • 02Isolated loopsWhere the sensor input must be isolated from the 4 to 20 mA loop.
  • 03Pre-configured supplyUnits can be supplied pre-configured for the sensor and range you need.
Compare the range

How the TxIsoPack-USB compares

The highlighted row is this instrument. Tap any other name to open its page.

TxIsoPack-USB compared with the temperature measurement range
InstrumentTypeInputOutputSupplyMounting
ACS Thermocont TS4S Temperature SwitchTemperature switchPt100 class A, built in2x PNP switch, 4 to 20 mA option10.5 to 35 VDCG½" or G¼" thread, compression fitting
Datexel DAT 1066 Head-Mount Temperature TransmitterHead-mount transmitter, isolatedRTD, thermocouple, mV, resistance4 to 20 mA7 to 32 VdcDIN B head, DIN rail kit
NOVUS TxBlock-USB and TxRail-USB Temperature TransmittersHead-mount or DIN rail transmitterThermocouple, Pt100, Pt1000, NTC, mV4 to 20 mA; 0 to 10 V on TxRail-USB8 to 35 Vdc (TxBlock-USB)Sensor head or DIN rail
NOVUS TxIsoPack-USB Isolated Temperature TransmitterHead-mount transmitter, isolatedPt100, thermocouple, mV4 to 20 mA or 20 to 4 mA12 to 35 VdcSensor head
NOVUS TxMini Compact Temperature TransmitterCompact transmitterPt100 or Pt1000, 3-wire4 to 20 mA8 to 35 VdcM12 or DIN 43650 connector
NOVUS RHT-Air Wireless Temperature and Humidity TransmitterWireless transmitterBuilt-in temperature and humidity sensorsWireless to AirGate-ModbusBattery or 10 to 35 VdcWall mount or probe extension
Proplant PCE

From Selection to a Working Signal in Your Control System

A temperature reading is only as useful as the signal that reaches the control room. Proplant PCE handles the steps around the instrument as well as the instrument itself.

01 / 04

Application review

We check the process temperature, sensor type, mounting and the signal your control system needs before recommending a transmitter.

02 / 04

Supply

Transmitters, switches and sensors from the brands on this page, with the brochure for your engineering file.

03 / 04

Configuration and installation

Range, sensor type and failure behaviour set before delivery, then mounting, cabling and termination by our E&I team.

04 / 04

Integration

Loop wiring and scaling in your PLC or SCADA, so the temperature on screen matches the process.

Before you order

What to tell us so we can recommend an instrument

Tick off what you already know. We will check the TxIsoPack-USB against your conditions, or suggest a better fit from our range.

FAQ

TxIsoPack-USB FAQ

What is the TxIsoPack-USB?

A fully isolated, two-wire, loop-powered temperature transmitter from NOVUS with a 4 to 20 mA output, for mounting inside a sensor head.

Which sensors does it accept?

Pt100 in 2, 3 or 4 wires, thermocouples J, K, T, E, N, R, S and B, and 0 to 50 mV signals.

How much isolation does it have?

1000 Vac for 1 minute between the input and the output.

How accurate is it?

Total accuracy is 0.3 % of the maximum range for thermocouples and 0.2 % for Pt100 and voltage. It is based on the sensor's full range, even when you set a narrower range.

How is it configured?

By connecting it directly to a PC USB port and using the NOVUS TxConfig software. No extra interface, converter or driver is needed.

Can Proplant PCE help me choose the right temperature transmitter?

Yes. Send us the sensor type, temperature range, mounting and the output your control system needs, and our team will recommend a suitable instrument.

TxIsoPack-USB isolated temperature transmitter

Let's Discuss Your Temperature Application

Tell us what you are measuring, where the sensor sits and what the signal needs to do. We will come back with a recommendation and the brochure.

Scroll to Top