Datexel DAT 1066 Isolated Head-Mount Temperature Transmitter
An isolated two-wire universal transmitter that fits in a DIN B sensor head and turns RTD, thermocouple, mV, resistance or potentiometer signals into a 4 to 20 mA loop signal, configured from a PC.

Key Features of the Datexel DAT 1066
Universal input
Thermocouples J, K, S, R, B, E, T and N; Pt100, Pt1000, Ni100 and Ni1000 RTDs in 2, 3 or 4 wires; mV; resistance; and potentiometers.
Galvanic isolation
1500 Vac, 50 Hz for 1 minute between the input and the supply and output, removing the effects of ground loops.
PC configuration
Configured with PROSOFT on Windows with the loop connected, or through the PRODAT05 or PRODAT06 interface without the power loop.
Custom linearisation
Standard linearisation, none, or a custom per-step curve for non-standard sensors.
Burn-out alarm
Burn-out high or low on sensor failure, direct 4-20 mA or reverse 20-4 mA action, and a damping filter of 0.3 to 30 s.
Head or rail mounting
DIN B in-head mounting, or DIN rail (EN 50022) with the optional stirrup kit.
43 mm diameter, 24 mm high, about 50 g.
Datexel DAT 1066 Technical Specifications
Tap a group to filter the head mount temperature transmitter specifications, or show them all.

- 1500 VacIsolationinput to supply and output
- ±0.1 % f.s.RTD linearityTC ±0.2 % f.s.
- 7 to 32 VdcLoop supply
- -40 to +85 °COperating temperature
| Specification | Details |
|---|---|
| Thermocouple inputs | J -200 to 1200 °C; K -200 to 1370 °C; S and R -50 to 1760 °C; B 400 to 1820 °C; E -200 to 1000 °C; T -200 to 400 °C; N -200 to 1300 °C |
| RTD inputs (2, 3 or 4 wires) | Pt100 -200 to 850 °C; Pt1000 -200 to 200 °C; Ni100 -60 to 180 °C; Ni1000 -60 to 150 °C; min. span 50 °C |
| Voltage input | -100 to +700 mV, min. span 2 mV |
| Resistance and potentiometer | Resistance 0 to 300 Ω or 0 to 2000 Ω; potentiometer 0 to 200 Ω, 200 to 500 Ω, 0.5 to 50 kΩ |
| Input calibration | RTD: greater of ±0.1 % f.s. or ±0.2 °C; mV and TC: greater of ±0.1 % f.s. or ±10 µV |
| Linearity | TC ±0.2 % f.s.; RTD ±0.1 % f.s. |
| Cold junction compensation | ±0.5 °C, internal or external |
| Thermal drift | Full scale ±0.01 %/°C; CJC ±0.01 %/°C |
| Response time (10 to 90 %) | About 400 ms |
| Output | 4 to 20 mA on the two-wire loop, direct or reverse action |
| Burn-out values | Max. output about 20.5 mA; min. output about 3.8 mA; max. fault about 21.6 mA; min. fault about 3.5 mA |
| Damping filter | 0.3 to 30 s selectable, or off |
| Configuration | PROSOFT on Windows via PC, or PRODAT05/PRODAT06 without the loop connected |
| Mounting | DIN B in-head; optional DIN rail (EN 50022) with stirrup kit |
| Dimensions and weight | 43 mm diameter, 24 mm high, about 50 g |
| Supply voltage | 7 to 32 Vdc; reverse polarity protection 60 Vdc max. |
| Isolation | 1500 Vac, 50 Hz, 1 min, input to supply and output |
| Operating and storage temperature | -40 to +85 °C; humidity 0 to 90 % RH non-condensing |
| Housing | PC + ABS V0 self-extinguishing plastic |
| EMC and marking | Immunity EN 61000-6-2; emission EN 61000-6-4; CE mark |
Figures from the Datexel brochure. Confirm the version and options for your application before ordering.
Download BrochureHow does the Datexel DAT 1066 work?
Tap a step, or let it run, to follow the signal from the process to the control system.
Step by step:
Because it powers itself from the 4 to 20 mA loop, the DAT 1066 needs only two wires back to the control system. The isolated input stops ground loops between the sensor and the PLC from upsetting the reading.
Where the Datexel DAT 1066 is used
Typical applications for this head mount temperature transmitter, from the manufacturer's documentation.
- 01RTD temperature measurementPt100, Pt1000, Ni100 and Ni1000 sensors in 2, 3 or 4 wires.
- 02Thermocouple temperature measurementEight thermocouple types up to 1820 °C, with cold junction compensation.
- 03Resistance and potentiometer signalsLinear resistance, potentiometer and mV signals converted to 4 to 20 mA.
- 04Heavy industrial conditionsIsolated input where ground loops would otherwise affect the reading.
How the Datexel DAT 1066 compares
The highlighted row is this instrument. Tap any other name to open its page.
| Instrument | Type | Input | Output | Supply | Mounting |
|---|---|---|---|---|---|
| ACS Thermocont TS4S Temperature Switch | Temperature switch | Pt100 class A, built in | 2x PNP switch, 4 to 20 mA option | 10.5 to 35 VDC | G½" or G¼" thread, compression fitting |
| Datexel DAT 1066 Head-Mount Temperature Transmitter | Head-mount transmitter, isolated | RTD, thermocouple, mV, resistance | 4 to 20 mA | 7 to 32 Vdc | DIN B head, DIN rail kit |
| NOVUS TxBlock-USB and TxRail-USB Temperature Transmitters | Head-mount or DIN rail transmitter | Thermocouple, Pt100, Pt1000, NTC, mV | 4 to 20 mA; 0 to 10 V on TxRail-USB | 8 to 35 Vdc (TxBlock-USB) | Sensor head or DIN rail |
| NOVUS TxIsoPack-USB Isolated Temperature Transmitter | Head-mount transmitter, isolated | Pt100, thermocouple, mV | 4 to 20 mA or 20 to 4 mA | 12 to 35 Vdc | Sensor head |
| NOVUS TxMini Compact Temperature Transmitter | Compact transmitter | Pt100 or Pt1000, 3-wire | 4 to 20 mA | 8 to 35 Vdc | M12 or DIN 43650 connector |
| NOVUS RHT-Air Wireless Temperature and Humidity Transmitter | Wireless transmitter | Built-in temperature and humidity sensors | Wireless to AirGate-Modbus | Battery or 10 to 35 Vdc | Wall mount or probe extension |
From Selection to a Working Signal in Your Control System
A temperature reading is only as useful as the signal that reaches the control room. Proplant PCE handles the steps around the instrument as well as the instrument itself.
Application review
We check the process temperature, sensor type, mounting and the signal your control system needs before recommending a transmitter.
Supply
Transmitters, switches and sensors from the brands on this page, with the brochure for your engineering file.
Configuration and installation
Range, sensor type and failure behaviour set before delivery, then mounting, cabling and termination by our E&I team.
Integration
Loop wiring and scaling in your PLC or SCADA, so the temperature on screen matches the process.
What to tell us so we can recommend an instrument
Tick off what you already know. We will check the Datexel DAT 1066 against your conditions, or suggest a better fit from our range.
Other temperature instruments to consider
Datexel DAT 1066 FAQ
What is the Datexel DAT 1066?
An isolated two-wire universal transmitter, programmable by PC, that mounts in a DIN B sensor head and gives a 4 to 20 mA output.
Which sensors can be connected?
Thermocouples J, K, S, R, B, E, T and N, Pt100, Pt1000, Ni100 and Ni1000 RTDs in 2, 3 or 4 wires, mV signals, resistance and potentiometers.
Why does isolation matter?
The 1500 Vac isolation between input and loop removes the effect of ground loops, which can otherwise shift or upset the reading in heavy industrial conditions.
How is the DAT 1066 configured?
With the PROSOFT software on a Windows PC, either with the loop connected or through the PRODAT05 or PRODAT06 interface without the power loop.
Can it be mounted on a DIN rail?
Yes. It is made for DIN B in-head mounting, and an optional kit mounts it on an EN 50022 DIN rail.
Can Proplant PCE help me choose the right temperature transmitter?
Yes. Send us the sensor type, temperature range, mounting and the output your control system needs, and our team will recommend a suitable instrument.
Let's Discuss Your Temperature Application
Tell us what you are measuring, where the sensor sits and what the signal needs to do. We will come back with a recommendation and the brochure.