NOVUS TxIsoPack-USB Isolated Head-Mount Temperature Transmitter
A fully isolated, two-wire, loop-powered temperature transmitter for the sensor head. The 4 to 20 mA output is linearised and isolated, and the sensor type and range are set straight from a PC USB port.

Key Features of the TxIsoPack-USB
Fully isolated
1000 Vac for 1 minute between input and output, on a loop-powered two-wire 4 to 20 mA transmitter.
Pt100, thermocouple and mV
Pt100 in 2, 3 or 4 wires, thermocouples J, K, T, E, N, R, S and B, and 0 to 50 mV.
Direct or reverse output
4 to 20 mA or 20 to 4 mA, linear with the measured temperature, with 12-bit (0.004 mA) resolution.
USB configuration
Sensor type and range set by connecting to a PC USB port, with no extra interface or driver.
Head-mount housing
ABS housing, 44 mm diameter and 24 mm maximum height, for mounting inside the sensor head.
Reverse polarity protection
Internal protection against reversed supply polarity, with internal cold junction compensation for thermocouples.
TxIsoPack-USB Technical Specifications
Tap a group to filter the isolated temperature transmitter specifications, or show them all.

- 1000 VacIsolationinput to output, 1 min
- 0.2 %Accuracyof max. range, Pt100 and mV
- 12 to 35 VdcSupply
- ≤ 500 msResponse time
| Specification | Details |
|---|---|
| Pt100 input | 2, 3 or 4 wires; -200 to 650 °C; min. span 40 °C; 0.17 mA excitation; α = 0.00385 to IEC 60751 |
| Thermocouple inputs | J -100 to 760 °C; K -150 to 1370 °C; T -160 to 400 °C; E -90 to 720 °C; N -270 to 1300 °C; R and S -50 to 1760 °C; B 500 to 1820 °C |
| Voltage input | 0 to 50 mV, min. span 5 mV; impedance > 1 MΩ |
| Total accuracy | 0.3 % of max. range for thermocouples; 0.2 % of max. range for Pt100 and voltage |
| Cold junction compensation | Internal, for thermocouples |
| Response time | ≤ 500 ms |
| Output | 4 to 20 mA or 20 to 4 mA, two-wire, linear with the measured temperature |
| Output resolution | 0.004 mA (12 bits) |
| Max. load | RL = (Vdc - 12) / 0.02 |
| Configuration | Mini-B USB cable to a PC, TxConfig software |
| Housing | ABS, 44 mm diameter, 24 mm maximum height, for the sensor head |
| Supply | 12 to 35 Vdc across the transmitter; internal reverse polarity protection |
| Isolation | 1000 Vac for 1 minute, input to output |
| Operating conditions | -20 to 75 °C; 0 to 90 % RH |
| EMC | EN 50081-2, EN 50082-2 |
Figures from the NOVUS TxIsoPack-USB product page and the TxIsoPack operating manual. Accuracy is a percentage of the sensor's maximum range, not the range you set. Confirm the version and options for your application before ordering.
NOVUS product pageHow does the TxIsoPack-USB work?
Tap a step, or let it run, to follow the signal from the process to the control system.
Step by step:
The TxIsoPack-USB takes its power from the 4 to 20 mA loop, so only two wires run back to the control system. Isolation keeps a grounded thermocouple or a noisy plant earth from disturbing the loop.
Where the TxIsoPack-USB is used
Typical applications for this isolated temperature transmitter, from the manufacturer's documentation.
- 01Head-mounted temperature assembliesMounts inside the connection head of an RTD or thermocouple assembly.
- 02Isolated loopsWhere the sensor input must be isolated from the 4 to 20 mA loop.
- 03Pre-configured supplyUnits can be supplied pre-configured for the sensor and range you need.
How the TxIsoPack-USB compares
The highlighted row is this instrument. Tap any other name to open its page.
| Instrument | Type | Input | Output | Supply | Mounting |
|---|---|---|---|---|---|
| ACS Thermocont TS4S Temperature Switch | Temperature switch | Pt100 class A, built in | 2x PNP switch, 4 to 20 mA option | 10.5 to 35 VDC | G½" or G¼" thread, compression fitting |
| Datexel DAT 1066 Head-Mount Temperature Transmitter | Head-mount transmitter, isolated | RTD, thermocouple, mV, resistance | 4 to 20 mA | 7 to 32 Vdc | DIN B head, DIN rail kit |
| NOVUS TxBlock-USB and TxRail-USB Temperature Transmitters | Head-mount or DIN rail transmitter | Thermocouple, Pt100, Pt1000, NTC, mV | 4 to 20 mA; 0 to 10 V on TxRail-USB | 8 to 35 Vdc (TxBlock-USB) | Sensor head or DIN rail |
| NOVUS TxIsoPack-USB Isolated Temperature Transmitter | Head-mount transmitter, isolated | Pt100, thermocouple, mV | 4 to 20 mA or 20 to 4 mA | 12 to 35 Vdc | Sensor head |
| NOVUS TxMini Compact Temperature Transmitter | Compact transmitter | Pt100 or Pt1000, 3-wire | 4 to 20 mA | 8 to 35 Vdc | M12 or DIN 43650 connector |
| NOVUS RHT-Air Wireless Temperature and Humidity Transmitter | Wireless transmitter | Built-in temperature and humidity sensors | Wireless to AirGate-Modbus | Battery or 10 to 35 Vdc | Wall mount or probe extension |
From Selection to a Working Signal in Your Control System
A temperature reading is only as useful as the signal that reaches the control room. Proplant PCE handles the steps around the instrument as well as the instrument itself.
Application review
We check the process temperature, sensor type, mounting and the signal your control system needs before recommending a transmitter.
Supply
Transmitters, switches and sensors from the brands on this page, with the brochure for your engineering file.
Configuration and installation
Range, sensor type and failure behaviour set before delivery, then mounting, cabling and termination by our E&I team.
Integration
Loop wiring and scaling in your PLC or SCADA, so the temperature on screen matches the process.
What to tell us so we can recommend an instrument
Tick off what you already know. We will check the TxIsoPack-USB against your conditions, or suggest a better fit from our range.
Other temperature instruments to consider
TxIsoPack-USB FAQ
What is the TxIsoPack-USB?
A fully isolated, two-wire, loop-powered temperature transmitter from NOVUS with a 4 to 20 mA output, for mounting inside a sensor head.
Which sensors does it accept?
Pt100 in 2, 3 or 4 wires, thermocouples J, K, T, E, N, R, S and B, and 0 to 50 mV signals.
How much isolation does it have?
1000 Vac for 1 minute between the input and the output.
How accurate is it?
Total accuracy is 0.3 % of the maximum range for thermocouples and 0.2 % for Pt100 and voltage. It is based on the sensor's full range, even when you set a narrower range.
How is it configured?
By connecting it directly to a PC USB port and using the NOVUS TxConfig software. No extra interface, converter or driver is needed.
Can Proplant PCE help me choose the right temperature transmitter?
Yes. Send us the sensor type, temperature range, mounting and the output your control system needs, and our team will recommend a suitable instrument.
Let's Discuss Your Temperature Application
Tell us what you are measuring, where the sensor sits and what the signal needs to do. We will come back with a recommendation and the brochure.