NOVUS N1040i Universal Process Indicator with Alarm Relays
A universal process indicator in a 48 x 48 mm case that reads thermocouple, Pt100 and linear signals, with up to two alarm relays and an optional retransmission output or 24 Vdc supply.

Key Features of the NOVUS N1040i
Universal input
Thermocouples J, K, T, N, R, S, B and E, Pt100, 0 to 20 mA, 4 to 20 mA, 0 to 50 mV, 0 to 5 V and 0 to 10 V.
Alarm relays
Alarm 1 relay SPDT, 240 Vac, 30 Vdc, 3 A; alarm 2 relay SPST, 240 Vac, 30 Vdc, 1.5 A.
Retransmission or supply
Optional 0 to 20 or 4 to 20 mA retransmission (500 Ω max.), or a 24 Vdc auxiliary source, 20 mA max.
Display range
-1999 to 9999 on the display, from 15-bit internal resolution.
RS485 option
An optional RS485 interface on the -485 models.
Compact and sealed
48 x 48 x 80 mm, about 75 g, IP65 front, CE and UL.
NOVUS N1040i Technical Specifications
Tap a group to filter the process indicator specifications, or show them all.

- 0.2 %Accuracyof span, Pt100 and linear
- 2Alarm relays
- 48 x 48Panel sizemm
- IP65Protectionfront
| Specification | Details |
|---|---|
| Inputs | Thermocouples J, K, T, N, R, S, B, E; Pt100; 0 to 20 mA, 4 to 20 mA, 0 to 50 mV, 0 to 5 V, 0 to 10 V |
| Accuracy | TC J, K, T, E: 0.25 % of span, 1 °C; TC N, R, S, B: 0.25 % of span, 3 °C; Pt100: 0.2 % of span; mA, mV and V: 0.2 % of span |
| Resolution | Internal 32767 levels (15 bits); display 12000 levels (-1999 to 9999) |
| Alarm 1 | Relay SPDT, 240 Vac / 30 Vdc / 3 A |
| Alarm 2 | Relay SPST, 240 Vac / 30 Vdc / 1.5 A |
| Retransmission | 0 to 20 mA or 4 to 20 mA, 500 Ω max. (model dependent) |
| Communication | Optional RS485 |
| Models | N1040i-RR, -RA, -RE, -RR-485, -RA-485, -RE-485 |
| Dimensions and weight | 48 x 48 x 80 mm; about 75 g |
| Auxiliary source | 24 Vdc (5 %), 20 mA max. (model dependent) |
| Power supply | 100 to 240 Vac (±10 %), 50/60 Hz; 48 to 240 Vdc (±10 %); max. 6 VA |
| Operating temperature | 0 to 50 °C |
| Protection | Case IP65; back panel IP30 |
| Approvals | CE, UL |
Figures from the NOVUS N1040i brochure. The brochure lists RS485 as the communication option and does not list USB. Confirm the model for your application before ordering.
Download BrochureHow does the NOVUS N1040i work?
Tap a step, or let it run, to follow the signal from the field to the control system.
Step by step:
The N1040i puts a reading on the panel door and acts on it locally. Alarm relays switch a horn, pump or interlock, and the retransmission option passes the value to a PLC or recorder.
Where the NOVUS N1040i is used
Typical uses for this process indicator, based on what it does.
- 01Panel indicationA local display of temperature, pressure, level or flow on a panel door.
- 02Local alarmsHigh and low alarms through two relays.
- 03Transmitter supplyPowering a 4 to 20 mA transmitter from the 24 Vdc auxiliary source.
How the NOVUS N1040i compares
Other digital indicators and controllers in our range. The highlighted row is this product. Tap any other name to open its page.
| Product | Type | Signals | Outputs and communication | Supply | Mounting |
|---|---|---|---|---|---|
| ACS DPA Digital Display Unit | Digital display unit | 0/4 to 20 mA, 0 to 10 V | Isolated analogue out, up to 4 relays, Bluetooth or USB | 18 to 36 V DC or 186 to 253 VAC | Panel, field or DIN rail |
| NOVUS N1050 PID Temperature Controller | PID controller | Thermocouple J, K, T, S; Pt100 | SSR pulse, relays, USB, optional Modbus RTU | 100 to 240 Vac/dc | Panel, 48 x 48 mm |
| NOVUS N1040i Process Indicator | Process indicator | Thermocouple, Pt100, mA, mV, V | 2 relays, optional retransmission and RS485 | 100 to 240 Vac or 48 to 240 Vdc | Panel, 48 x 48 mm |
| NOVUS N1540 Universal Indicator | Universal indicator | Thermocouple, Pt100, mA, mV, V | 2 relays, USB, optional Modbus RTU | 100 to 240 Vac/dc | Panel, 96 x 48 mm |
| NOVUS LoopView Loop-Powered Indicator | Loop-powered indicator | 4 to 20 mA loop | Local LED display | Loop powered | On the sensor connector |
From Selection to a Working Signal in Your Control System
A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.
Application review
We check the signals, channel count, network and mounting before recommending a device.
Supply
Instruments and modules from the brands on this page, with the brochure for your engineering file.
Configuration and installation
Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.
Integration
Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.
What to tell us so we can recommend a device
Tick off what you already know. We will check the NOVUS N1040i against your application, or suggest a better fit from our range.
Other automation products to consider
NOVUS N1040i FAQ
What is the NOVUS N1040i?
A universal process indicator in a 48 x 48 mm case with up to two alarm relays and optional retransmission.
Which inputs does it accept?
Thermocouples J, K, T, N, R, S, B and E, Pt100, and 0 to 20 mA, 4 to 20 mA, 0 to 50 mV, 0 to 5 V and 0 to 10 V signals.
Can it retransmit the value?
Yes, on the retransmission models it gives a 0 to 20 or 4 to 20 mA output with up to 500 Ω load.
Does it have a communication port?
An RS485 interface is available on the -485 models.
What supply does it need?
100 to 240 Vac or 48 to 240 Vdc, with a maximum of 6 VA.
Can Proplant PCE help me choose the right automation device?
Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.
Let's Discuss Your Automation Project
Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.