Balluff IO-Link Hubs for Digital and Analogue Signals
Field-mounted hubs that collect up to 16 digital inputs and outputs, or 8 analogue signals, and bring them to one port of an IO-Link master.

Key Features of the Balluff IO-Link hub
Digital hubs
BNI00KL and BNI0091: 16 PNP inputs and 16 PNP outputs on 8 M12 slots.
Analogue hub
BNI00AJ: 8 inputs for 0 to 10 V, -10 to 10 V, 4 to 20 mA, 0 to 20 mA, Pt100, Pt1000 and thermocouple type J or K.
High output current
BNI00KL switches 12 outputs at 2 A and 4 at 4 A, with a 16 A actuator current sum.
Built-in monitoring
BNI00KL also reports vibration and internal temperature.
Extension port
BNI00KL and BNI0091 have an extension port and single-channel monitoring.
Field mounting
IP67 when threaded in, die-cast zinc (BNI00KL, BNI00AJ) or PBT with stainless steel inserts (BNI0091).
Balluff IO-Link hub Technical Specifications
Tap a group to filter the IO-Link hub specifications, or show them all.

- 16 / 16Digital I/OBNI00KL, BNI0091
- 8Analogue inputsBNI00AJ
- 18 to 30.2VDCoperating voltage
- IP67Protectionwhen threaded in
| Specification | Details |
|---|---|
| BNI00KL (BNI LH5-314-S52-Z071) | 16 PNP/NPN inputs Type 1, Type 3; 16 PNP outputs; IO-Link 1.1.3, COM3 (230.4 kBaud); process data 12 bytes in, 2 bytes out |
| BNI0091 (BNI IOL-302-S02-R026) | 16 PNP inputs Type 3; 16 PNP outputs; IO-Link 1.1, COM2 (38.4 kBaud); process data cycle min. 6.0 ms |
| BNI00AJ (BNI IOL-719-002-Z012) | 8 analogue inputs: 0 to 10 V, -10 to 10 V, 0 to 5 V, -5 to 5 V, 5 to 10 V, 4 to 20 mA, 0 to 20 mA, Pt100, Pt1000, thermocouple type J and K; IO-Link 1.1, COM2 (38.4 kBaud); process data cycle min. 55 ms |
| Switching current | BNI00KL: 12x 2 A, 4x 4 A. BNI0091: 16x 2 A |
| Current sum | BNI00KL: 2 A sensor, 16 A actuator. BNI0091: 9 A sensor, 9 A actuator. BNI00AJ: 4 A sensor, 4 A actuator |
| Additional functions | BNI00KL: vibration and internal temperature; extension port and single-channel monitoring on BNI00KL and BNI0091 |
| Connection to master | BNI00KL: M12x1 female, 4-pin, A-coded. BNI0091, BNI00AJ: M12x1 male, 4-pin, A-coded |
| Slots | 8x M12x1 female, 5-pin, A-coded |
| Power in | BNI00KL: M12x1 male, 5-pin, L-coded. BNI0091: 7/8" male, 4-pin |
| Housing | BNI00KL, BNI00AJ: die-cast zinc, nickel-plated, 68 x 31.8 x 181.5 mm. BNI0091: PBT GF30 with 1.4404 stainless steel inserts, 68 x 39.1 x 183.5 mm |
| Operating voltage | 18 to 30.2 VDC |
| Protection | IP67, when threaded in |
| Ambient temperature | BNI00KL: -25 to 60 °C. BNI0091: -5 to 55 °C. BNI00AJ: -5 to 70 °C |
Figures from the Balluff product page for each model, read in November 2026. Balluff names BNI00KL as the recommended replacement for the earlier BNI0035 hub. Confirm the version for your signals before ordering.
Data sheets by modelHow does the Balluff IO-Link hub work?
Tap a step, or let it run, to follow the signal from the field to the control system.
Step by step:
The hub is an IO-Link device. Standard switching sensors, valves or analogue signals wire into its M12 slots, and it sends all of them as one block of process data over a single cable to one port of the IO-Link master. That saves master ports and long individual cable runs back to the cabinet.
Where the Balluff IO-Link hub is used
Typical uses for this IO-Link hub, based on what it does.
- 01Machine I/OGathering many switching sensors and valves on a machine onto one master port.
- 02Analogue signalsBringing 4 to 20 mA, 0 to 10 V, Pt100 and thermocouple signals onto IO-Link.
- 03Less cablingOne M12 cable back to the master in place of a cable per signal.
How the Balluff IO-Link hub compares
Other io-link and balluff in our range. The highlighted row is this product. Tap any other name to open its page.
| Product | Type | Signals | Outputs and communication | Supply | Mounting |
|---|---|---|---|---|---|
| Balluff Multiprotocol IO-Link Masters | IO-Link master | 8 IO-Link ports | PROFINET, EtherNet/IP, EtherCAT, Modbus TCP | 18 to 30 VDC | Machine, IP67 to IP69K |
| Balluff IO-Link Sensor and Actuator Hubs | IO-Link hub | 16 DI and 16 DO, or 8 analogue in | IO-Link to one master port | 18 to 30.2 VDC | Machine, IP67 |
| Balluff IO-Link Sensors | IO-Link sensors | Inductive, optical, capacitive, magnetic, distance, pressure | IO-Link 1.1 plus switching or analogue | 10 to 30 VDC, model dependent | Machine and process |
| Balluff Condition Monitoring Sensors | Condition monitoring sensor | 3-axis vibration, contact temperature | IO-Link | 24 V DC | Machine mount, IP67 to IP69K |
| autosen AS005 IO-Link Flow Sensor | Thermal flow sensor | Flow and temperature, liquids and gases | 2 switching, 4 to 20 mA, IO-Link | 18 to 30 V DC | M18 x 1.5 adapter, IP65 and IP67 |
| Balluff IO-Link Safety Hub | Safety I/O hub | 12 safe inputs, 2 safe outputs | PROFIsafe over IO-Link | 19.2 to 30 V | Machine, IP67 |
| Balluff Heartbeat Power Supplies with IO-Link | 24 V power supply | 192 to 360 W | IO-Link diagnostics | 85 to 264 V AC in, model dependent | DIN rail IP20 or field IP67 |
| Balluff M12 Cordsets and Splitters | M12 cordsets | Single, double-ended, Y-splitter, NAMUR | Sensor and power cable | 250 VDC / 250 VAC, 4 A | IP67 to IP69K |
From Selection to a Working Signal in Your Control System
A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.
Application review
We check the signals, channel count, network and mounting before recommending a device.
Supply
Instruments and modules from the brands on this page, with the brochure for your engineering file.
Configuration and installation
Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.
Integration
Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.
What to tell us so we can recommend a device
Tick off what you already know. We will check the Balluff IO-Link hub against your application, or suggest a better fit from our range.
Balluff IO-Link hub FAQ
What is an IO-Link hub?
An IO-Link device with several M12 slots that collects standard digital or analogue signals and sends them to one port of an IO-Link master.
How many signals does one hub take?
BNI00KL and BNI0091 take 16 digital inputs and 16 outputs. BNI00AJ takes 8 analogue inputs.
Which analogue signals does BNI00AJ accept?
0 to 10 V, -10 to 10 V, 0 to 5 V, -5 to 5 V, 5 to 10 V, 4 to 20 mA, 0 to 20 mA, Pt100, Pt1000 and type J or K thermocouples.
Do I need an IO-Link master?
Yes. The hub plugs into one port of a master such as the Balluff multiprotocol IO-Link master.
Can Proplant PCE help me choose the right automation device?
Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.
Let's Discuss Your Automation Project
Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.