NOVUS RHT-Air Wireless Temperature and Humidity Transmitter
A wireless temperature and relative humidity transmitter with a local display. Paired with the AirGate-Modbus, it brings temperature, humidity and dew point into a Modbus system without running signal cables.

Key Features of the NOVUS RHT-Air
Temperature, humidity and dew point
High-accuracy sensors measure temperature and relative humidity, and the transmitter calculates dew point.
Wireless to Modbus
Works with the AirGate-Modbus, which connects up to 246 Modbus slaves, wired or wireless, to a Modbus master over USB or RS485.
Local LCD
Readings show on the transmitter, and parameters can be changed on the device without a computer.
Diagnostics
Battery level, wireless signal strength, connection type and measured values, plus a network topology view in DigiConfig.
Battery or external power
An internal 3.6 V lithium ½ AA battery lasts typically about a year.
External 10 to 35 Vdc is optional on the RHT-Air and required on the RHT-Air NB.
Wall mount or probe extension
ABS housing, IP65, 70 x 60 x 35 mm.
The DM version has a stainless probe extension of 150 or 250 mm.
NOVUS RHT-Air Technical Specifications
Tap a group to filter the wireless temperature transmitter specifications, or show them all.

- ±1 °CTemperature accuracy
- ±3 % RHHumidity accuracy20 to 80 % RH at 25 °C
- 500 mWireless rangeopen field, typical
- IP65Protection
| Specification | Details |
|---|---|
| Measured variables | Temperature, relative humidity, dew point |
| Temperature accuracy | ±1 °C |
| Humidity accuracy | ±3 % RH from 20 to 80 % RH at 25 °C |
| Sensor and probe limits | -20 to 80 °C; 0 to 100 % RH |
| Wireless protocol | IEEE 802.15.4 |
| Typical range | 100 m indoors; 500 m open field |
| Gateway | AirGate-Modbus, with USB and RS485 to the Modbus master |
| Display | LCD |
| Configuration | DigiConfig software for Windows (free), over USB |
| Versions | RHT-Air (battery or external power); RHT-Air NB (external power only); WM wall mount; DM probe extension |
| Probe | Nylon; DM version stainless steel extension 150 or 250 mm |
| Dimensions | 70 x 60 x 35 mm |
| Battery | Internal 3.6 V lithium ½ AA; typically about 1 year |
| External supply | 10 to 35 Vdc, < 100 mA (optional on RHT-Air, required on RHT-Air NB) |
| Electronics operating limits | 0 to 65 °C; 0 to 95 % RH |
| Housing and protection | ABS, IP65 |
Figures from the NOVUS Automation brochure. Confirm the version and options for your application before ordering.
Download BrochureHow does the NOVUS RHT-Air work?
Tap a step, or let it run, to follow the signal from the process to the control system.
Step by step:
Each RHT-Air reports to an AirGate-Modbus, which presents the readings to your PLC, SCADA or data logger as Modbus registers. An AirGate can also act as a repeater to extend the network.
Where the NOVUS RHT-Air is used
Typical applications for this wireless temperature transmitter, from the manufacturer's documentation.
- 01Room and multi-room monitoringOne transmitter per room, reporting to one gateway.
- 02Long-range star networksUp to 500 m in open field, with repeaters to extend the network.
- 03Remote supervisionReadings on a corporate or Modbus network, or logged locally with a FieldLogger.
How the NOVUS RHT-Air compares
The highlighted row is this instrument. Tap any other name to open its page.
| Instrument | Type | Input | Output | Supply | Mounting |
|---|---|---|---|---|---|
| ACS Thermocont TS4S Temperature Switch | Temperature switch | Pt100 class A, built in | 2x PNP switch, 4 to 20 mA option | 10.5 to 35 VDC | G½" or G¼" thread, compression fitting |
| Datexel DAT 1066 Head-Mount Temperature Transmitter | Head-mount transmitter, isolated | RTD, thermocouple, mV, resistance | 4 to 20 mA | 7 to 32 Vdc | DIN B head, DIN rail kit |
| NOVUS TxBlock-USB and TxRail-USB Temperature Transmitters | Head-mount or DIN rail transmitter | Thermocouple, Pt100, Pt1000, NTC, mV | 4 to 20 mA; 0 to 10 V on TxRail-USB | 8 to 35 Vdc (TxBlock-USB) | Sensor head or DIN rail |
| NOVUS TxIsoPack-USB Isolated Temperature Transmitter | Head-mount transmitter, isolated | Pt100, thermocouple, mV | 4 to 20 mA or 20 to 4 mA | 12 to 35 Vdc | Sensor head |
| NOVUS TxMini Compact Temperature Transmitter | Compact transmitter | Pt100 or Pt1000, 3-wire | 4 to 20 mA | 8 to 35 Vdc | M12 or DIN 43650 connector |
| NOVUS RHT-Air Wireless Temperature and Humidity Transmitter | Wireless transmitter | Built-in temperature and humidity sensors | Wireless to AirGate-Modbus | Battery or 10 to 35 Vdc | Wall mount or probe extension |
From Selection to a Working Signal in Your Control System
A temperature reading is only as useful as the signal that reaches the control room. Proplant PCE handles the steps around the instrument as well as the instrument itself.
Application review
We check the process temperature, sensor type, mounting and the signal your control system needs before recommending a transmitter.
Supply
Transmitters, switches and sensors from the brands on this page, with the brochure for your engineering file.
Configuration and installation
Range, sensor type and failure behaviour set before delivery, then mounting, cabling and termination by our E&I team.
Integration
Loop wiring and scaling in your PLC or SCADA, so the temperature on screen matches the process.
What to tell us so we can recommend an instrument
Tick off what you already know. We will check the NOVUS RHT-Air against your conditions, or suggest a better fit from our range.
Other temperature instruments to consider
NOVUS RHT-Air FAQ
What does the RHT-Air measure?
Temperature and relative humidity, and it calculates dew point. Readings show on its LCD and are sent wirelessly.
How far can it transmit?
Typically 100 m indoors and 500 m in open field. An AirGate-Modbus can act as a repeater to extend the network.
How does it connect to a PLC or SCADA?
Through the AirGate-Modbus gateway, which presents the readings to a Modbus master over USB or RS485.
How long does the battery last?
Typically about one year on the internal 3.6 V lithium battery. External 10 to 35 Vdc power is also available.
How accurate is it?
±1 °C for temperature and ±3 % RH between 20 and 80 % RH at 25 °C.
Can Proplant PCE help me choose the right temperature transmitter?
Yes. Send us the sensor type, temperature range, mounting and the output your control system needs, and our team will recommend a suitable instrument.
Let's Discuss Your Temperature Application
Tell us what you are measuring, where the sensor sits and what the signal needs to do. We will come back with a recommendation and the brochure.