Balluff IO-Link Sensors for Position, Distance and Pressure
Sensors that send their switching state, measured value and diagnostics over IO-Link, so they can be set up and monitored from the PLC.

Key Features of the Balluff IO-Link sensors
Inductive
BES05Y7: M12 stainless steel, 0.5 to 4 mm, IP68 and IP69K, -40 to 85 °C.
Photoelectric
BOS027M: retroreflective, 0 to 10 m, red LED, PNP NO and NC.
Capacitive
BCS01CP: compact cubic sensor, 0.5 to 12 mm teachable, IO-Link 1.1.3.
Magnetic field
BMF00LC: T-slot cylinder sensor with 8 teachable switching points over a 60 mm travel path.
Laser distance
BOD002L: 30 to 200 mm, with IO-Link, 4 to 20 mA and two switching outputs.
Pressure
BSP00YH: 0 to 400 bar with display, 4 to 20 mA or 0 to 10 V and two switching outputs.
Balluff IO-Link sensors Technical Specifications
Tap a group to filter the IO-Link sensors specifications, or show them all.

- 6Sensor families
- IO-Link 1.1Interface
- 0 to 400barpressure model
- cULusApprovalall six models
| Specification | Details |
|---|---|
| Inductive: BES05Y7 | Sensing range 0.5 to 4 mm, quasi-flush; M12x1, 1.4404 stainless steel; PNP, NPN or push-pull NO/NC; IO-Link 1.1 |
| Photoelectric: BOS027M | Retroreflective, divergent beam; range 0 to 10 m; red LED; PNP NO, PNP NC; IO-Link 1.1 |
| Capacitive: BCS01CP | Sensing range 0.5 to 12 mm, teachable; 34 x 16 x 8 mm; push-pull or IO-Link 1.1.3 |
| Magnetic field: BMF00LC | T-slot, installs from above; 8 teachable switching points; IO-Link 1.1 |
| Laser distance: BOD002L | Range 30 to 200 mm; repeat accuracy ±0.25 mm or better; IO-Link 1.1, 4 to 20 mA, 2x PNP/NPN NO/NC |
| Pressure: BSP00YH | 0 to 400 bar; G 1/4" (DIN 3852), 1.4301 stainless steel; IO-Link 1.1, 4 to 20 mA or 0 to 10 V, 2x PNP/NPN switching outputs |
| Operating voltage | 10 to 30 VDC (BES05Y7, BOS027M, BMF00LC); 18 to 30 VDC (BCS01CP, BSP00YH); 15 to 30 VDC (BOD002L) |
| Protection | IP68 and IP69K (BES05Y7); IP67 (BMF00LC; BSP00YH when threaded in); IP65 (BCS01CP) |
| Ambient temperature | -40 to 85 °C (BES05Y7, BSP00YH); -25 to 80 °C (BCS01CP, BMF00LC) |
| Approvals | CE, UKCA, cULus and WEEE on all six; Ecolab on BES05Y7 and BOS027M |
Figures from the Balluff product page for each model, read in November 2026. Where a figure is not listed for a model it was not shown on its page. The Balluff data sheet for each model is linked below. Many more versions exist in each family; ask us for the one that fits.
- Balluff BES05Y7 inductive sensor data sheet (PDF)
- Balluff BOS027M photoelectric sensor data sheet (PDF)
- Balluff BCS01CP capacitive sensor data sheet (PDF)
- Balluff BMF00LC magnetic field sensor data sheet (PDF)
- Balluff BOD002L laser distance sensor data sheet (PDF)
- Balluff BSP00YH pressure sensor data sheet (PDF)
How does the Balluff IO-Link sensors work?
Tap a step, or let it run, to follow the signal from the field to the control system.
Step by step:
An IO-Link sensor connects to one port of an IO-Link master with a standard M12 cable. Besides its switching or analogue signal, it sends measured values and diagnostics, and accepts new settings from the control system, so a replacement sensor can be set up automatically.
Where the Balluff IO-Link sensors is used
Typical uses for this IO-Link sensors, based on what it does.
- 01Position detectionInductive, capacitive and photoelectric sensing of parts and machine positions.
- 02Cylinder monitoringMagnetic field sensors on pneumatic cylinder slots.
- 03Distance and pressureMeasured values for gauging and hydraulic or process pressure.
How the Balluff IO-Link sensors compares
Other io-link and balluff in our range. The highlighted row is this product. Tap any other name to open its page.
| Product | Type | Signals | Outputs and communication | Supply | Mounting |
|---|---|---|---|---|---|
| Balluff Multiprotocol IO-Link Masters | IO-Link master | 8 IO-Link ports | PROFINET, EtherNet/IP, EtherCAT, Modbus TCP | 18 to 30 VDC | Machine, IP67 to IP69K |
| Balluff IO-Link Sensor and Actuator Hubs | IO-Link hub | 16 DI and 16 DO, or 8 analogue in | IO-Link to one master port | 18 to 30.2 VDC | Machine, IP67 |
| Balluff IO-Link Sensors | IO-Link sensors | Inductive, optical, capacitive, magnetic, distance, pressure | IO-Link 1.1 plus switching or analogue | 10 to 30 VDC, model dependent | Machine and process |
| Balluff Condition Monitoring Sensors | Condition monitoring sensor | 3-axis vibration, contact temperature | IO-Link | 24 V DC | Machine mount, IP67 to IP69K |
| autosen AS005 IO-Link Flow Sensor | Thermal flow sensor | Flow and temperature, liquids and gases | 2 switching, 4 to 20 mA, IO-Link | 18 to 30 V DC | M18 x 1.5 adapter, IP65 and IP67 |
| Balluff IO-Link Safety Hub | Safety I/O hub | 12 safe inputs, 2 safe outputs | PROFIsafe over IO-Link | 19.2 to 30 V | Machine, IP67 |
| Balluff Heartbeat Power Supplies with IO-Link | 24 V power supply | 192 to 360 W | IO-Link diagnostics | 85 to 264 V AC in, model dependent | DIN rail IP20 or field IP67 |
| Balluff M12 Cordsets and Splitters | M12 cordsets | Single, double-ended, Y-splitter, NAMUR | Sensor and power cable | 250 VDC / 250 VAC, 4 A | IP67 to IP69K |
From Selection to a Working Signal in Your Control System
A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.
Application review
We check the signals, channel count, network and mounting before recommending a device.
Supply
Instruments and modules from the brands on this page, with the brochure for your engineering file.
Configuration and installation
Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.
Integration
Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.
What to tell us so we can recommend a device
Tick off what you already know. We will check the Balluff IO-Link sensors against your application, or suggest a better fit from our range.
Balluff IO-Link sensors FAQ
What is an IO-Link sensor?
A sensor that, besides switching or measuring, sends its values, parameters and diagnostics to the control system through an IO-Link master.
Which Balluff IO-Link sensors do you supply?
Inductive, photoelectric, capacitive, magnetic field, laser distance and pressure sensors.
Do I need an IO-Link master?
Yes, to use IO-Link. The sensor plugs into one port of a master such as the Balluff multiprotocol IO-Link master.
Is there a sensor for washdown areas?
The BES05Y7 inductive sensor is rated IP68 and IP69K and has Ecolab approval.
Can Proplant PCE help me choose the right automation device?
Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.
Let's Discuss Your Automation Project
Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.