Automation products

Automation products that get field signals into your control system

Data loggers and IIoT, digital indicators and controllers, Ethernet I/O, signal isolators and converters, and IO-Link. Selected for the signals, the network and the system they report to, then configured and integrated by Proplant PCE.

NOVUSAcromagDatexelACS-Control-SystemBalluffautosen
Why it matters

The link between the field and the control room

Automation depends on the signal path as much as on the PLC. A reading that arrives scaled wrongly, picks up noise through a ground loop, or never reaches the network leaves operators guessing and control loops running on bad data.

Indicators put values where operators can see them, isolators and converters keep signals clean, Ethernet I/O and IO-Link carry them over the network, and data loggers keep a record. We match each device to your signals and to the system that reads them.

Product groups

Four groups, one signal path

Pick a group to see what it does and which products we supply in it.

DATA ACQUISITION AND IIOT

Data loggers and a cloud platform that record plant signals and make them available remotely.

The range

22 automation products

Filter by group, open a product for its full specification sheet, or download the manufacturer's brochure.

At a glance

Compare the range

Swipe the table sideways on a phone. Tap a name to open its page.

Automation product range compared
ProductTypeSignalsOutputs and communicationSupplyMounting
Data acquisition and IIoT
NOVUS Cloud IIoT PlatformIIoT cloud platformData from NOVUS devicesDashboards, email and SMS alarmsHosted platformOnline
NOVUS FieldLogger Data LoggerData logger8 universal analogue, 8 digital I/ORS485 Modbus RTU, Ethernet, Modbus TCP, USB100 to 240 VacPanel
NOVUS LogBox Connect Wireless Data LoggerWireless data loggerUniversal analogue, 1 digitalBluetooth, Wi-Fi with Modbus TCP and MQTT, USB4 AA batteries or 10 to 30 VdcWall or field, IP40
Digital indicators and controllers
ACS DPA Digital Display UnitDigital display unit0/4 to 20 mA, 0 to 10 VIsolated analogue out, up to 4 relays, Bluetooth or USB18 to 36 V DC or 186 to 253 VACPanel, field or DIN rail
NOVUS N1050 PID Temperature ControllerPID controllerThermocouple J, K, T, S; Pt100SSR pulse, relays, USB, optional Modbus RTU100 to 240 Vac/dcPanel, 48 x 48 mm
NOVUS N1040i Process IndicatorProcess indicatorThermocouple, Pt100, mA, mV, V2 relays, optional retransmission and RS485100 to 240 Vac or 48 to 240 VdcPanel, 48 x 48 mm
NOVUS N1540 Universal IndicatorUniversal indicatorThermocouple, Pt100, mA, mV, V2 relays, USB, optional Modbus RTU100 to 240 Vac/dcPanel, 96 x 48 mm
NOVUS LoopView Loop-Powered IndicatorLoop-powered indicator4 to 20 mA loopLocal LED displayLoop poweredOn the sensor connector
Signal converters and isolators
Acromag BusWorks XT1540 Ethernet I/O ModuleEthernet I/O4 discrete I/O8 analogue out; Modbus TCP, EtherNet/IP or PROFINET12 to 32 V DCDIN rail, 22.5 mm
Acromag 961EN and 962EN Analogue Input Ethernet I/OEthernet I/O6 differential current or voltage inputsModbus TCP or EtherNet/IP15 to 36 V DCDIN rail
Acromag 981EN, 982EN and 983EN Discrete Ethernet I/OEthernet I/O12 discrete inputs, outputs or bothModbus TCP or EtherNet/IP15 to 36 V DCDIN rail
Datexel DAT 511 Loop-Powered Current IsolatorLoop isolator0 to 20 mAIsolated 0 to 20 mALoop poweredDIN rail, 17 mm
Datexel DAT 4135 Isolated Universal Signal ConverterUniversal converterRTD, TC, mV, V, mA, resistanceIsolated current or voltage18 to 30 VdcDIN rail
Datexel DAT 4035 Loop-Powered Universal TransmitterUniversal transmitterRTD, TC, mV, V, mA, resistanceIsolated 4 to 20 mA loopLoop powered, 10 to 32 VdcDIN rail
IO-Link and Balluff
Balluff Multiprotocol IO-Link MastersIO-Link master8 IO-Link portsPROFINET, EtherNet/IP, EtherCAT, Modbus TCP18 to 30 VDCMachine, IP67 to IP69K
Balluff IO-Link Sensor and Actuator HubsIO-Link hub16 DI and 16 DO, or 8 analogue inIO-Link to one master port18 to 30.2 VDCMachine, IP67
Balluff IO-Link SensorsIO-Link sensorsInductive, optical, capacitive, magnetic, distance, pressureIO-Link 1.1 plus switching or analogue10 to 30 VDC, model dependentMachine and process
Balluff Condition Monitoring SensorsCondition monitoring sensor3-axis vibration, contact temperatureIO-Link24 V DCMachine mount, IP67 to IP69K
autosen AS005 IO-Link Flow SensorThermal flow sensorFlow and temperature, liquids and gases2 switching, 4 to 20 mA, IO-Link18 to 30 V DCM18 x 1.5 adapter, IP65 and IP67
Balluff IO-Link Safety HubSafety I/O hub12 safe inputs, 2 safe outputsPROFIsafe over IO-Link19.2 to 30 VMachine, IP67
Balluff Heartbeat Power Supplies with IO-Link24 V power supply192 to 360 WIO-Link diagnostics85 to 264 V AC in, model dependentDIN rail IP20 or field IP67
Balluff M12 Cordsets and SplittersM12 cordsetsSingle, double-ended, Y-splitter, NAMURSensor and power cable250 VDC / 250 VAC, 4 AIP67 to IP69K
Before you order

What to tell us so we can recommend a device

Send us the signals, channel count, network and mounting, and our team will recommend a suitable device.

Support

From Selection to a Working Signal in Your Control System

A field signal is only as useful as the value that reaches the control room. Proplant PCE handles the configuration, panel work and integration around the device as well as the device itself.

01 / 04

Application review

We check the signals, channel count, network and mounting before recommending a device.

02 / 04

Supply

Instruments and modules from the brands on this page, with the brochure for your engineering file.

03 / 04

Configuration and installation

Ranges, alarms, addresses and network settings set up, then panel building, cabling and termination by our E&I team.

04 / 04

Integration

Mapping into your PLC, SCADA or historian, and testing until the value on screen matches the field.

FAQ

Frequently asked questions

What does Proplant PCE supply for automation?

Data loggers and an IIoT platform, digital indicators and PID controllers, Ethernet I/O, signal isolators and converters, and IO-Link devices, together with the panel work, configuration and integration around them.

How do I get field signals onto an Ethernet network?

An Ethernet I/O module such as the Acromag 961EN or 983EN reads analogue or discrete signals in a remote panel and publishes them over Modbus TCP or EtherNet/IP.

When do I need a signal isolator?

When a ground loop, a shared signal or a noisy earth upsets a reading. The Datexel DAT 511 isolates a current loop without a separate supply.

Can a sensor be converted to 4 to 20 mA on the DIN rail?

Yes. The Datexel DAT 4035 converts RTD, thermocouple, resistance and other signals to an isolated 4 to 20 mA loop, and the DAT 4135 to current or voltage.

Which indicator suits a field transmitter with no spare power?

The NOVUS LoopView is powered by the 4 to 20 mA loop and fits between the sensor and its connector.

Can I log data at a site with no power?

Yes. The NOVUS LogBox Connect runs on AA batteries and is read by Bluetooth, Wi-Fi or USB.

What do I need to start with IO-Link?

An IO-Link master for your fieldbus, such as the Balluff multiprotocol IO-Link master, and IO-Link devices such as Balluff IO-Link sensors or the autosen AS005 flow sensor. Safety devices can join the same system through the Balluff Safety Hub.

Can Proplant PCE help me choose the right automation device?

Yes. Send us the signals, channel count, network and mounting, and our team will recommend a suitable device and set it up for your system.

Do these devices connect to my PLC or SCADA?

Yes. Depending on the model they offer Modbus RTU, Modbus TCP, EtherNet/IP, PROFINET, MQTT, relays or analogue signals. Tell us what your system uses and we will match it.

Next step

Let's Discuss Your Automation Project

Tell us what signals you need to bring in, where the device sits and what system it reports to. We will come back with a recommendation and the brochure.